Overview: The ME 5200 CR is a signal conditioner/amplifier designed for use with gage sensors or potentiometer sensors. It features integrated shunt calibration, a three-position gain switch, and an adjustable scale via a potentiometer. An integrated LCD voltage meter with 3 ½ digits is also included.
Technical Specifications:
  • Excitation Voltage: 220V, 50 Hz
  • Sensor Excitation Voltage: 4 to 12 V, regulated to 10^-5 (factory setup at 10V)
  • Band Pass: 0-15 KHz (factory setup at 500 Hz)
  • Consumption: 50 mA
  • Calibration Reference Resistor: Counter voltage 1 mV/V for gages, 10 mV/V for semiconductors, and 100% for potentiometers
  • Input Resistance: Greater than 10^12 Ohms
  • Zero Range: ± 10% minimum range
  • Output Signal: 0-10 Vdc (maximum 20 mA)
  • Operating Temperature: 0 to +50°C (32 to 120°F)
  • Storage Temperature: -10 to +70°C (14 to 160°F)
Installation:
  • Rack System: Height 3U, Width 10 F (1 F = 5.08 mm)
  • Sensor Connection: AMPHENOL 4 pin base connector
  • Analog Output: Isolated BNC base
  • Power Supply: 220 Volts on standard CEE22 plug with integrated fuse
Additional Information: The MB 2001 conditioner is compatible with a wide range of gage sensors, including those for pressure, load, torque, and displacement, as well as potentiometers. Specifications are subject to change without notice.
See more

Catalog excerpts

ME5200-1

Signal conditionner/amplifier Type ME 5200 CR Designed for gages sensors or potentiometer sensors Integrated shunt calibration 3 position gain switch Scale adjustable with potentiometer LCD voltage meter integrated - 3 ½ digits The MB 2001 conditioner is designed to be associated with a large range of gage sensors (pressure, load, torque, displacement) and potentiometers. Technical specification Excitation voltage V Sensor excitation voltage 220 - 50 Hz 4 to 12 V regulation 10 puissance-5 (factory setup 10V) Band pass Consumption 0-15 KHz (500 Hz factory setup) mA Calibration reference resistor 50 By conter voltage 1 mV/V (gages) - 10 mV/V (semi-conductors) et 100% (pot.) Input resistance Ohm Zero range > 10 power 12 ± 10% range minimum Output signal Vdc 0-10V (20 mA maximum) Operating temperature °C 0 to +50 (32 to 120°F) Storage temperature -10 to +70°C (14 to 160°F) TECHNIQUES MODERNES D'EXTENSOMETRIE Parc d'activités de Signes - B.P. 734 - 83030 TOULON Cedex 9 Tel. 04.94.10.00.51 - Fax 04.94.10.00.52 Specifications are subject to change without notice Page 1

 Open the catalog to page 1
ME5200-2

Installation Rack system heigh 3U - width 10 F (1 F = 5.08 mm) Sensor connection on AMPHENOL 4 pin base connector Analog output on isolated BNC base Power 220 Volts on standard CEE22 plug with integrated fuse TECHNIQUES MODERNES D'EXTENSOMETRIE Parc d'activités de Signes - B.P. 734 - 83030 TOULON Cedex 9 Tel. 04.94.10.00.51 - Fax 04.94.10.00.52 Specifications are subject to change without notice Page 2

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.