PowerTrap® GT / GP Series
8Pages

{{requestButtons}}

Catalog excerpts

PowerTrap® GT / GP Series - 1

Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series

Open the catalog to page 1
PowerTrap® GT / GP Series - 2

Effective Condensate Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment are some of the many benefits of condensate drainage and recovery. The GP/GT series provides the perfect solution for optimizing condensate processing in many applications. Prevention of Heat Exchanger “Stall” ¡Stabilized temperature control improves product quality ¡Elimination of water hammer prevents equipment damage and improves safety ¡Prevention of corrosion caused by condensate accumulation ¡Some models are designed for installation...

Open the catalog to page 2
PowerTrap® GT / GP Series - 3

’s Series— The Total Solution to Heat Exchanger “Stall” Importance of “Stall” Prevention “Stall” prevents condensate from being discharged from heating equipment. It results in: "Stall" occurs and condensate backs up Press. Equip. press. As the “stall” cycle repeats, the steam pressure in the equipment varies above and below the back pressure, causing product temperature and quality fluctuations. Back press. Temp. ¡Process Temperature Swings Set temp. Product temp. Time ¡Water Hammer Damage Water hammer can occur when backed-up condensate re-evaporates, or as incoming hot steam hits cooler...

Open the catalog to page 3
PowerTrap® GT / GP Series - 4

Benefits Built-in Steam Trap Improves Performance (GT Series) ¡Automatically switches between pump and trap operation, in response to process conditions ¡Internal trap mechanism always matches pump output, with no damage to trap, and eliminates need for sizing ¡No need for external steam trap means simplified compact design and lowered installation costs ¡Trap body and plug are both stainless steel for minimum leakage and maximum life Snap-action Mechanism Maximizes Life Instantaneous Switching ¡Heat-treat hardened stainless steel internals ¡Durable nickel-based alloy compression coil...

Open the catalog to page 4
PowerTrap® GT / GP Series - 5

Construction GT14/GT10 GT10M/GT10L GP14/GP10 GP10M/GP10L Mechanical pump with built-in trap Mechanical pump GP10F GT5C Mechanical pump with retrofitable mechanism Compact mechanical pump with built-in trap ¡Materials Body (except GP10F, GT5C) 1 Body (GP10F) Body (GT5C) Cover (except GP10F, GT5C) 2 Cover (GP10F) Cover (GT5C) Cover Gasket (GP10/GT10, GP10M/GT10M, GP10L/GT10L, GP10F) 3 Cover Gasket (GP14/GT14) Cover Gasket (GT5C) Cast Iron or Cast Steel * 4 Lever Unit (GP14/GT14, GP10/GT10 only) Fabricated Carbon Steel ** Cast Iron or Stainless Steel 5 Snap-action Unit Cast Iron or Cast Steel...

Open the catalog to page 5
PowerTrap® GT / GP Series - 6

Systems for Many Different Applications series meets a variety of condensate processing needs. Closed System Open System Exhaust pipe Equipment Steam trap Equipment Condensate recovery line Reservoir System Overview Venting pipe Exhaust pipe Discharge to atmosphere Receiver Overflow line The Steam trap Equipment PowerTrap PowerTrap Benefits Notes Std. Pump Discharge Capacity ¡ o need for external steam trap (GT model features N built-in trap) ¡ o flash steam discharge N ¡mall reservoir S ¡ se with vacuum equipment possible U ¡ ollection of condensate from multiple equipment C possible ¡ an...

Open the catalog to page 6
PowerTrap® GT / GP Series - 7

Installation Piping Examples (For explanation purposes only, not intended as installation designs.) ¡Closed System Temperature controller Steam supply Condensate recovery line Air Vent (to atmosphere, pipe safely) Steam trap Heat exchanger PowerTrap To Pit Filling head Condensate reservoir Height to equipment condensate outlet Pump exhaust Motive medium supply Control valve Back pressure Steam line Exhaust and air discharge lines Closed system condensate recovery using a GT PowerTrap Condensate line Check valve Strainer; 40 mesh or finer Gate valve or needle valve Gate valve or ball valve...

Open the catalog to page 7
PowerTrap® GT / GP Series - 8

¡Installation Piping Example for GT5C* Easy Maintenance Product Outlet ¡Inlet/outlet check valves and motive medium intake valve unit are removable while connected to the piping ¡The unit can be disconnected by removing only 2 bolts ¡The body can be disassembled by removing six bolts while still connected to the piping Steam Control Valve Condensate Motive Medium Supply Simple Installation Product Inlet ¡Only motive medium intake pipe - no exhaust pipe necessary ¡Inlet/outlet piping is linear, streamlined and efficient ¡Built-in air vent and check valves minimize external installation GT5C...

Open the catalog to page 8

All TLV Euro Engineering catalogs and technical brochures

  1. SC series

    2 Pages

  2. CK3

    1 Pages

  3. AIR VENTS

    8 Pages

  4. CK3MG

    2 Pages

  5. Sight Glass

    4 Pages

  6. Separators

    2 Pages

  7. brochure

    60 Pages

  8. Steam Traps

    34 Pages