1. Catalogs
  2. TIRA GmbH
  3. TV 59356/AIT-480
video corpo

TV 59356/AIT-480

TV 59356/AIT-480

TV 59356/AIT-480

Product catalog summary
Technical Parameters:
The Vibration Test System TV 59356/AIT-480 is designed to deliver a rated peak force of 56000 Npk RMS for sine and random vibrations, and 160000 Npk for shock. It operates within a frequency range of 5 - 2500 Hz, with a main resonance frequency greater than 2100 Hz. The system allows for maximum displacements of 63.5 mm for sine and random, and 76.2 mm for shock, with maximum velocities of 2.0 m/s for sine and random, and 3.5 m/s for shock. The maximum acceleration is 100 g for sine, 80 g for random, and 350 g for shock. The system supports a maximum payload of 910 kg and requires a minimum compressed air supply of 600 kPa.
Scope of Delivery:
The system includes a vibration exciter S 59356, trunnion mount with integrated vibration isolation, power amplifier, cooling blower, connection box for blower, and various cables and hoses. Optional features include different armature hole patterns, airglide option, silent operation, wheels and rails, thermobarrier, climatic chamber support kit, remote control software, and noise reduction solutions.
Amplifier Specifications:
The amplifier A 6 26 11 126 provides an output power of 75000 VARMS, with a frequency range from DC to 5 kHz. It supports a maximum voltage of ±212 VRMS and a current of 600 ARMS. The amplifier features a total harmonic distortion of less than 0.2% and a signal-to-noise ratio greater than 80 dB. It includes interlocks for overload, temperature, displacement, cooling air, compressed air, phase monitoring, and emergency stop.
Cooling Blower Specifications:
The cooling blower TB 7/FUK/20 has a maximum volume flow rate of 5820 m³/h and a total pressure difference of 16 kPa. It operates with a motor output of 20 kW and a maximum frequency of 105 Hz. The blower is equipped with options for noise reduction, including a silencer and acoustic enclosures.
Features:
The system includes an AIT-trunnion with integrated vibration isolation, a coarse filter unit, fully automatic pneumatic load compensation, automatic centering, and a degauss kit to reduce stray magnetic fields. It is manufactured in Germany and includes a service hotline for support.
See more

Catalog excerpts

TV 59356/AIT-480-1

S 59356/AIT-480 (Example drawing) Dimensions in mm 56000/56000/160000 N 5 - 2500 Hz > 2100 Hz 63.5/63.5/76.2 mm 2.0/2.0/3.5 m/s 100/80/350 g 250 N/mm 55 kg 910 kg 1.5 mT 480 mm 600 kPa 4800 kg Temperature, displacement, cooling air, overcurrent, compressed air 1) Random force vector according to ISO 5344 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) Impact by moving to static mass and frequency is possible 4) measured at 150 mm above armature inserts For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter S 59356 Trunnion mount with integrated vibration isolation (AIT) Power amplifier Cooling blower Connection box for blower Connection cables (each 10 m) Power cable (10 m) for cooling blower (CEE 63 connector) Blower hose ø175 mm (5 m) Compressed-air hose NW 7,2 (Standard) (5 m) GmbH © TIRA GmbH • Version 06 - 2022-01-31 Options: Different hole pattern of armature (different pitch diameter and/or thread inserts) at customers request Airglide-option (Shaker movable on air cushions) Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 9 - 15 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Water-cooled acoustic enclosure for cooling blower (Noise reduction 30 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: AIT-trunnion with integrated vibration isolation < 3 Hz Coarse filter unit Fully automatic pneumatic load compensation AIT fixable Automatic centering of the AIT-System and the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Pk-Pk Sine/Random/Shock3 Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass Max. payload Magn. stray field4 Armature diameter Min. required compressed air supply Total mass Interlocks TECHNICAL PARAMETERS Vibration Test Syste

 Open the catalog to page 1
TV 59356/AIT-480-2

TECHNICAL PARAMETERS Cooling blower TB 7/FUK/20 Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltageRMS Total Harmonic Distortion Signal to noise ratio Field voltage Field current Power supply (Standard) Max. volume flow rate Max. total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Connection box (fixation to wall): Mass Dimensions (WxHxD) Power supply (variable) Recommended fuse protection (Standard) Max.current consumption at 400 V Max. power consumption at 400 V Recommended...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.