TV 59349/AIT-480 - 1

S 59356/AIT-480 (Example drawing) Dimensions in mm 49500/48000/148500 N 5 - 2500 Hz > 2100 Hz 63.5/63.5/76.2 mm 2.0/2.0/3.5 m/s 91/75/224 g 250 N/mm 55 kg 910 kg 1.5 mT 480 mm 600 kPa 4800 kg Temperature, displacement, cooling air, overcurrent, compressed air 1) Random force vector according to ISO 5344 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) Impact by moving to static mass and frequency is possible 4) measured at 150 mm above armature inserts For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter S 59356 Trunnion mount with integrated vibration isolation (AIT) Power amplifier Cooling blower Connection box for blower Connection cables (each 10 m) Power cable (10 m) for cooling blower (CEE 63 connector) Blower hose ø175 mm (5 m) Compressed-air hose NW 7,2 (Standard) (5 m) GmbH © TIRA GmbH • Version 03 - 2022-01-31 Options: Different hole pattern of armature (different pitch diameter and/or thread inserts) at customers request Airglide-option (Shaker movable on air cushions) Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 9 - 15 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Water-cooled acoustic enclosure for cooling blower (Noise reduction 30 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: AIT-trunnion with integrated vibration isolation < 3 Hz Coarse filter unit Fully automatic pneumatic load compensation AIT fixable Automatic centering of the AIT-System and the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: st@tira-gmbh.de Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Pk-Pk Sine/Random/Shock3 Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass Max. payload Magn. stray field4 Armature diameter Min. required compressed air supply Total mass Interlocks TECHNICAL PARAMETERS Vibration Test Syste

Open the catalog to page 1
TV 59349/AIT-480 - 2

TECHNICAL PARAMETERS Cooling blower TB 7/FUK/20 Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltageRMS Total Harmonic Distortion Signal to noise ratio Field voltage Field current Power supply (Standard) Max. volume flow rate Max. total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Connection box (fixation to wall): Mass Dimensions (WxHxD) Power supply (variable) Recommended fuse protection (Standard) Max.current consumption at 400 V Max. power consumption at 400 V...

Open the catalog to page 2

All TIRA GmbH catalogs and technical brochures

  1. TV 50350-120

    2 Pages