Technical Parameters of Vibration Exciter S 59327/*-640:
  • Rated Peak Force: Sine/Random/Shock: 27000/27000/80000 Npk RMS pk
  • Frequency Range: 5 - 2000 Hz
  • Main Resonance Frequency: > 1900 Hz
  • Max. Displacement: 50.8 mm Peak-Peak
  • Max. Velocity: Sine/Random/Shock: 2.0/1.8/3.0 m/s
  • Max. Acceleration: Sine/Random/Shock: 66/50/131 g
  • Suspension Stiffness: 150 N/mm
  • Effective Moving Mass: 40.5 kg
  • Max. Payload: 610 kg
  • Total Mass with Trunnion: RIT/AIT/LB: 2350/2700/2250 kg
  • Magnetic Stray Field: Standard/Low Degaussing: <2/<1 mT
  • Armature Diameter: 640 mm
  • Compressed Air Supply: 600-1000 kPa
  • Interlocks: Temperature, displacement, cooling air, overcurrent, compressed air
Scope of Delivery:
  • Vibration exciter 27 kN
  • Trunnion mount (AIT, RIT or LB)
  • Power amplifier 25 kVA
  • Cooling blower
  • Frequency converter
  • Connection cables (10 m each)
  • Power cables (10 m each)
  • Blower hose ø150 mm (5 m)
  • Compressed-air hose NW 7.2 (5 m)
Options:
  • Different hole pattern of armature
  • AIT-trunnion mount with integrated vibration isolation
  • Low degaussing kit
  • Squeak&Rattle (Silent operation without blower)
  • Wheels&Rails (incl. 3m rails)
  • Airglide-option
  • Thermobarrier (-40°C to +140°C)
  • Chamber leadthrough
  • Climatic chamber support kit
  • Remote control (Software)
  • ASM-Mode (Auto Shutdown Manager)
  • Silencer for cooling blower
  • Acoustic enclosure for cooling blower
  • Water-cooled acoustic enclosure
  • Cable extension
  • Factory acceptance test
Features:
  • Vibration isolation < 3 Hz (AIT), < 6 Hz (RIT;LB)
  • Coarse filter unit
  • Fully automatic pneumatic load compensation
  • Automatic centering of the AIT-System and the armature
  • Degauss kit to reduce stray magnetic field
  • Made in Germany
  • Service hotline
Technical Parameters of Amplifier A 3 08 11 042:
  • Output Power: 25000 VARMS
  • Frequency Range: DC - 5 kHz
  • Voltage, Max.: ±212 VRMS
  • Current, Max.: 200 ARMS
  • Signal Input Voltage: 10 V
  • Total Harmonic Distortion: < 0.2 %RMS
  • Signal to Noise Ratio: > 80 dB
  • Field Voltage: 105 V
  • Field Current: 75 A
  • Total Mass: 450 kg
  • Dimensions: 600 x 2200 x 800 mm
  • Power Supply: 3~ / N / PE 400 V±5% 50 Hz, CEE 63
  • Recommended Fuse Protection: 50 A slow
  • Max. Power Consumption: 30 kVA
  • Interlocks: Overload, Temperature, Displacement, Cooling air, Compressed air, Phase monitoring, Emergency stop
Technical Parameters of Cooling Blower TB 7/FUK/11:
  • Max. Volume Flow Rate: 1920 m³/h
  • Max. Total Pressure Difference: 16 kPa
  • Motor Output: 11 kW
  • Max. Frequency: 105 Hz
  • Hose Diameter: 150 mm
  • Hose Length (Std.): 5 m
  • Total Mass: 113 kg
  • Dimensions: 625 x 775 x 602 mm
  • Max. Sound Pressure Level: 102 dB(A)
  • Switch Box Mass: 10 kg
  • Switch Box Dimensions: 300 x 300 x 250 mm
  • Power Supply: 3~ / PE 400 V±5% 50 Hz, CEE 32
  • Recommended Fuse Protection: 32 A slow
  • Max. Current Consumption: 25 A
Options for Cooling Blower:
  • Silencer TB 7/FUK-SI
  • Acoustic enclosure TB 7/FUK-AE
  • Water-cooled acoustic enclosure WWT
  • Hose length customization
See more

Catalog excerpts

TV 59327/*-640-1

S 59327/AIT-640 (Example drawing) Dimensions in mm © TIRA GmbH • Version 09 - 2019-10-08 Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) Features: Vibration isolation < 3 Hz (AIT) < 6 Hz (RIT;LB) Coarse filter unit Fully automatic pneumatic load compensation AIT fixable Automatic centering of the AIT-System and the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Options: Different hole pattern of armature (different pitch diameter and/or thread inserts) at customers request AIT-trunnion mount with integrated vibration isolation RIT-trunnion mount LB-frame SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Options: Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Airglide-option (Shaker movable on air cushions) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) ASM-Mode (Auto Shutdown Manager) Silencer for cooling blower (Noise reduction 9 - 15 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Water-cooled acoustic enclosure for cooling blower (Noise reduction 30 dB(A)) Cable extension Factory acceptance test adjustable feet 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature inserts For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. * RIT, AIT or LB (explanation see TIRA selection guide page 7) Scope of delivery: Vibration exciter 27 kN Trunnion mount (AIT, RIT or LB) Power amplifier 25 kVA Cooling blower Frequency converter Connection cables (each 10 m) Power cables (each 10 m) for amplifier (CEE 63 connector) and cooling blower (CEE 32 connector) Blower hose ø150 mm (5 m) Compressed-air hose NW 7,2 (Standard) (5 m) 27000/27000/80000 N 5 - 2000 Hz > 1900 Hz 50.8 mm 2.0/1.8/3.0 m/s 66/50/131 g 150 N/mm 40.5 kg 610 kg 2350/2700/2250 kg <2/<1 mT 640 mm 600-1000 kPa Temperature, displacement, cooling air, overcurrent, compressed air Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass Max. payload Total mass with trunnion RIT/AIT/LB* Magn. stray field std./low degaussing3 Armature diameter Required compressed air supply (load-dependent) Interlocks TECHNICAL PARAMETERS Vibration exciter S 59327/*-640 352 1162 armature and AIT-system in middle position

 Open the catalog to page 1
TV 59327/*-640-2

TECHNICAL PARAMETERS Cooling blower TB 7/FUK/11 Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltage Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage Field current Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection (Standard) Max. power consumption at 400 V Interlocks: Max. volume flow rate Max. total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Switch box (fixation to wall): Mass Dimensions (WxHxD) Power...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.