1. Catalogs
  2. TIRA GmbH
  3. TV 59327/*-340
video corpo

TV 59327/*-340

TV 59327/*-340

TV 59327/*-340

Product catalog summary
Technical Parameters:
  • Vibration Exciter S 59327/*-340: Rated peak force for Sine/Random/Shock is 27000/27000/80000 Npk RMS pk. Frequency range is 5 - 3000 Hz with a main resonance frequency of > 2400 Hz. Maximum displacement is 50.8 mm, and maximum velocity for Sine/Random/Shock is 2.0/1.8/3.0 m/s. Maximum acceleration is 84/65/167 g. The system has a suspension stiffness of 150 N/mm and an effective moving mass of 29.0 kg. Maximum payload is 610 kg.
  • Amplifier A 3 08 11 042: Output power is 25000 VARMS with a frequency range of DC - 5 kHz. Maximum voltage is ±212 VRMS and current is 200 ARMS. Total harmonic distortion is < 0.2 %RMS.
  • Cooling Blower TB 7/FUK/11: Maximum volume flow rate is 1920 m³/h with a total pressure difference of 16 kPa. Motor output is 11 kW with a maximum frequency of 105 Hz.
Scope of Delivery:
  • Includes vibration exciter, trunnion mount, power amplifier, cooling blower with frequency converter, connection cables, power cables, blower hose, and compressed-air hose.
Options and Features:
  • Options include different trunnion mounts, low degaussing kit, Squeak&Rattle operation, Wheels&Rails, Airglide-option, Thermobarrier, and more.
  • Features include vibration isolation, automatic pneumatic load compensation, automatic centering, and a degauss kit.
Interlocks and Safety:
  • Interlocks for temperature, displacement, cooling air, overcurrent, compressed air, and emergency stop are included to ensure safety.
Additional Information:
  • Made in Germany with a service hotline available. The system is subject to modifications as per the latest version dated 2019-10-08.
See more

Catalog excerpts

TV 59327/*-340-1

S 59327/AIT-340 (Example drawing) Dimensions in mm 27000/27000/80000 N 5 - 3000 Hz > 2400 Hz 50.8 mm 2.0/1.8/3.0 m/s 84/65/167 g 150 N/mm 29.0 kg 610 kg 2350/2700/2250 kg <1.5/<0.8 mT 340 mm 600-1000 kPa Temperature, displacement, cooling air, overcurrent, compressed air height adjustable 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature inserts For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. * RIT, AIT or LB (explanation see TIRA selection guide page 7) SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM GmbH © TIRA GmbH • Version 10 - 2019-10-08 Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) Features: Vibration isolation < 3 Hz (AIT) < 6 Hz (RIT;LB) Coarse filter unit Fully automatic pneumatic load compensation AIT fixable Automatic centering of the AIT-System and the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Options: AIT-trunnion mount with integrated vibration isolation RIT-trunnion mount LB-frame Low Pressure unit for operation with vacuum chambers Options: Different hole pattern of armature (different pitch diameter and/or thread inserts) at customers request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Airglide-option (Shaker movable on air cushions) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) ASM-Mode (Auto Shutdown Manager) Silencer for cooling blower (Noise reduction 9 - 15 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Water-cooled acoustic enclosure for cooling blower (Noise reduction 30 dB(A)) Cable extension Factory acceptance test Scope of delivery: Vibration exciter 27 kN Trunnion mount (AIT, RIT or LB) Power amplifier 25 kVA Cooling blower with frequency converter Connection cables (each 10 m) Power cables (each 10 m) for amplifier (CEE 63 connector) and cooling blower (CEE 32 connector) Blower hose ø150 mm (5 m) Compressed-air hose NW 7,2 (Standard) (5 m) Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass Max. payload Total mass with trunnion RIT/AIT/LB* Magn. stray field std./low degaussing3 Armature diameter Required compressed air supply (load-dependent) Interlocks TECHNICAL PARAMETERS Vibration exciter S 59327/*-340 1126 Armature and AIT-System in middle position

 Open the catalog to page 1
TV 59327/*-340-2

TECHNICAL PARAMETERS Cooling blower TB 7/FUK/11 Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltage Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage Field current Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection (Standard) Max. power consumption at 400 V Interlocks: Max. volume flow rate Max. total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Switch box (fixation to wall): Mass Dimensions (WxHxD) Power...