Technical Specifications
  • Vibration Exciter S 59322/*-340: Rated peak force for Sine/Random/Shock is 22000/17000/66000 Npk RMS pk. Frequency range is 5 - 3000 Hz with a main resonance frequency of > 2250 Hz. Maximum displacement is 63.5/63.5/76.2 mm, and maximum velocity is 2.0/2.0/3.5 m/s. Maximum acceleration is 80/55/200 g. The system has a suspension stiffness of 150 N/mm and an effective moving mass of 22.0 kg. Maximum payload is 300 kg.
  • Amplifier A 3 09 11 042: Output power is 22500 VARMS with a frequency range of DC - 5 kHz. Maximum voltage is ±212 VRMS and maximum current is 200 ARMS. Total harmonic distortion is < 0.2 %RMS, and signal to noise ratio is > 80 dB.
  • Cooling Blower TB 7/FUK/11: Maximum volume flow rate is 1920 m³/h with a total pressure difference of 16 kPa. Motor output is 11 kW, and maximum sound pressure level is 102 dB(A).
Scope of Delivery
  • Includes vibration exciter, trunnion mount, power amplifier, cooling blower, connection cables, power cables, blower hose, and compressed-air hose.
Options and Features
  • Options include different hole patterns, Squeak&Rattle operation, Wheels&Rails, Airglide-option, Thermobarrier, and more.
  • Features include vibration isolation, automatic centering, degauss kit, and energy management system.
Safety and Interlocks
  • Interlocks for temperature, displacement, cooling air, overcurrent, compressed air, and emergency stop are included to ensure safe operation.
Additional Information
  • For long-term tests, the load must be reduced to 80% to prevent damage. Continuous operation at maximum load is not recommended.
See more

Catalog excerpts

TV 59322/*-340-1

S 59322/AIT-340 (Example drawing) Dimensions in mm TECHNICAL PARAMETERS Vibration exciter S 59322/*-340 22000/17000/66000 N 5 - 3000 Hz > 2250 Hz 63.5/63.5/76.2 mm 2.0/2.0/3.5 m/s 80/55/200 g 150 N/mm 22.0 kg 300 kg 1750/2000 kg <1.5 mT 340 mm Min. 600 kPa Temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature inserts For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. * RIT or AIT (explanation see TIRA selection guide page 7) SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM © TIRA GmbH • Version 08 - 2022-03-10 Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) Features: Vibration isolation < 3 Hz (AIT) < 6 Hz (RIT) Coarse filter unit Fully automatic pneumatic load compensation AIT fixable Automatic centering of the AIT-System and the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Options: AIT-trunnion frame (see illustration) with integrated vibration isolation RIT-trunnion frame Options: Different hole pattern of armature (different pitch diameter and/or thread inserts) at customers request Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Airglide-option (Shaker movable on air cushions) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) ASM-Mode (Auto Shutdown Manager) Silencer for cooling blower (Noise reduction 9 - 15 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Cable extension Factory acceptance test Scope of delivery: Vibration exciter 22 kN Trunnion mount (RIT or AIT) Power amplifier 22.5 kVA Cooling blower Connection cables (each 10 m) Power cables (10 m) for amplifier (CEE 63 connector) and blower (CEE 32 connector) Blower hose ø150 mm (5 m) Compressed-air hose NW 7,2 (Standard) (5 m) Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass Max. payload Total mass with trunnion RIT/AIT* Magn. stray field3 Armature diameter Required compressed air supply Interlocks Vibration Test Syst

 Open the catalog to page 1
TV 59322/*-340-2

TECHNICAL PARAMETERS Cooling blower TB 7/FUK/11 Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltage Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage Field current Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection (Standard) Max. power consumption at 400 V Interlocks: Max. volume flow rate Max. total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Switch box (fixation to wall): Mass Dimensions (WxHxD) Power...

 Open the catalog to page 2