TV 57315/LS-230 - 1

TECHNICAL PARAMETERS Vibration exciter S 57315/LS-230 Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks 15000/13000/45000 N 2 - 3000 Hz >2300 Hz 50.8 mm 2.0/2.0/3.5 m/s 115/80/230 g 75 N/mm 13 kg 250 kg 1100 kg <1.5/<0.8 mT 230 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 15 kN Trunnion mount Power amplifier 22.5 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 63 connector) Blower hose ø140 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 3 - 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Cable extension Factory acceptance test Options: Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline GmbH © TIRA GmbH • Version 10 - 2019-07-05 Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: st@tira-gmbh.de Subject to modifications S 57315/LS-230 (Example drawing) Dimensions in mm TIRA Vibration Test Systems Vibration Test System

Open the catalog to page 1
TV 57315/LS-230 - 2

TECHNICAL PARAMETERS Cooling blower TB 120 FUK Output powerRMS Frequency range VoltageRMS, max. CurrentRMS, max. Signal input voltage Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage Field current Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection (Standard) Max. power consumption at 400 V (incl. blower) Interlocks: Max. volume flow rate Total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Power supply (standard) Max. current consumption...

Open the catalog to page 2

All TIRA GmbH catalogs and technical brochures

  1. TV 50350-120

    2 Pages