1. Catalogs
  2. TIRA GmbH
  3. TV 56280/LS-340
video corpo

TV 56280/LS-340

TV 56280/LS-340

TV 56280/LS-340

Product catalog summary
Technical Parameters:
  • Vibration Exciter S 56280/LS-340: Rated peak force for Sine/Random/Shock is 8000/7200/24000 Npk RMS pk. Frequency range is 2 - 3000 Hz with a main resonance frequency of >2500 Hz. Maximum displacement is 50.8 mm, and maximum velocity for Sine/Random/Shock is 2.0/2.0/3.5 m/s. Maximum acceleration is 88/65/200 g. The system has a suspension stiffness of 50 N/mm and an effective moving mass of 9.6 kg. Maximum payload is 250 kg, and total mass is 780 kg.
  • Cooling Blower TB 9 FUK: Maximum volume flow rate is 1080 m³/h with a total pressure difference of 9 kPa. Motor output is 4 kW, and maximum frequency is 90 Hz. The hose diameter is 140 mm, and standard hose length is 5 m. Total mass is 60 kg, and dimensions are 505 x 598 x 464 mm. Maximum sound pressure level is 99 dB(A).
  • Amplifier A 1 02 11 021 SV: Maximum output power is 15000 VARMS with a frequency range of DC - 5 kHz. Maximum voltage is ±212 VRMS, and current is 40-100 ARMS. Signal input voltage is 10 VRMS, with a total harmonic distortion of < 0.2 %RMS. Signal to noise ratio is > 80 dB. Total mass is 330 kg, and dimensions are 600 x 1740 x 800 mm.
Scope of Delivery:
  • Includes vibration exciter 8 kN, trunnion mount, power amplifier 15 kVA, cooling blower, connection cable, power cable, blower hose, and compressed-air hose.
Options and Features:
  • Options include different thread inserts, low degaussing kit, Squeak&Rattle operation, Wheels&Rails, thermobarrier, chamber leadthrough, climatic chamber support kit, remote control, silencer, acoustic enclosure, cable extension, and factory acceptance test.
  • Features include vibration isolation < 6 Hz, coarse filter unit, fully automatic pneumatic load compensation, automatic centering of the armature, and a degauss kit to reduce stray magnetic field.
Recommendations:
  • For long-term tests, reduce load to 80% to prevent damage from continuous operation at maximum load.
See more

Catalog excerpts

TV 56280/LS-340-1

S 56280/LS-340 (Example drawing) Dimensions in mm ø550 ø340 8000/7200/24000 N 2 - 3000 Hz >2500 Hz 50.8 mm 2.0/2.0/3.5 m/s 88/65/200 g 50 N/mm 9.6 kg 250 kg 780 kg <1.5/<0.8 mT 340 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 8 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø140 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 3 - 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline GmbH © TIRA GmbH • Version 09 - 2021-09-13 Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks TECHNICAL PARAMETERS Vibration exciter S 56280/LS-340 Vibration Test Syst

 Open the catalog to page 1
TV 56280/LS-340-2

TECHNICAL PARAMETERS Cooling blower TB 9 FUK Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Max. volume flow rate Total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Power...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.