Technical Parameters of Vibration Exciter S 56280/LS-180:
  • Rated Peak Force: Sine/Random/Shock: 8000/7200/24000 Npk RMS pk
  • Frequency Range: 2 - 3000 Hz
  • Main Resonance Frequency: >2900 Hz
  • Max. Displacement: 50.8 mm Peak-Peak
  • Max. Velocity: Sine/Random/Shock: 2.0/2.0/3.5 m/s
  • Max. Acceleration: Sine/Random/Shock: 93/72/186 g
  • Suspension Stiffness: 50 N/mm
  • Effective Moving Mass: 8.1 kg
  • Max. Payload: 250 kg
  • Total Mass: 765 kg
  • Magnetic Stray Field: <1.5/<0.8 mT
  • Armature Diameter: 180 mm
  • Compressed Air Supply: 600 kPa
  • Interlocks: Field coil temperature, displacement, cooling air, overcurrent, compressed air
Scope of Delivery:
  • Vibration exciter 8 kN
  • Trunnion mount
  • Power amplifier 15 kVA
  • Cooling blower
  • Connection and power cables
  • Blower and compressed-air hoses
Options:
  • Thread inserts customization
  • Low degaussing kit
  • Squeak & Rattle operation
  • Wheels & Rails
  • Thermobarrier
  • Chamber leadthrough
  • Climatic chamber support kit
  • Remote control software
  • Silencer and acoustic enclosure for noise reduction
  • Cable extension
  • Factory acceptance test
Features:
  • Vibration isolation < 6 Hz
  • Coarse filter unit
  • Automatic pneumatic load compensation
  • Automatic armature centering
  • Degauss kit
Technical Parameters of Cooling Blower TB 9 FUK:
  • Max. Volume Flow Rate: 1080 m³/h
  • Total Pressure Difference: 9 kPa
  • Motor Output: 4 kW
  • Max. Frequency: 90 Hz
  • Hose Diameter: 140 mm
  • Max. Sound Pressure Level: 99 dB(A)
Technical Parameters of Amplifier A 1 02 11 021 SV:
  • Max. Output Power: 15000 VARMS
  • Frequency Range: DC - 5 kHz
  • Voltage, Max.: ±212 VRMS
  • Current, Max.: 40-100 ARMS
  • Signal Input Voltage: 10 VRMS
  • Total Harmonic Distortion: < 0.2 %RMS
  • Signal to Noise Ratio: > 80 dB
  • Field Voltage: 140-280 V
  • Field Current: 6-8 A
  • Interlocks: Overload, temperature, displacement, cooling air, compressed air, phase monitoring, emergency stop
See more

Catalog excerpts

TV 56280/LS-180-1

S 56280/LS-180 (Example drawing) Dimensions in mm ø550 ø180 8000/7200/24000 N 2 - 3000 Hz >2900 Hz 50.8 mm 2.0/2.0/3.5 m/s 93/72/186 g 50 N/mm 8.1 kg 250 kg 765 kg <1.5/<0.8 mT 180 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 8 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø140 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) GmbH © TIRA GmbH • Version 09 - 2021-09-13 Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 3 - 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Cable extension Factory acceptance test 770 Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks TECHNICAL PARAMETERS Vibration exciter S 56280/LS-180

 Open the catalog to page 1
TV 56280/LS-180-2

TECHNICAL PARAMETERS Cooling blower TB 9 FUK Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Max. volume flow rate Total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level Power...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.