Technical Parameters
  • Vibration Exciter S 55240/LS-340: Rated peak force for Sine/Random/Shock is 4000/3600/12000 Npk RMS pk. Frequency range is 2 - 3000 Hz with a main resonance frequency of >2700 Hz. Maximum displacement is 50.8 mm, velocity is 2.0/2.0/2.4 m/s, and acceleration is 50/45/130 g. Suspension stiffness is 50 N/mm, effective moving mass is 8.3 kg, and max payload is 250 kg.
  • Cooling Blower TB 0310: Max volume flow rate is 315 m³/h with a total pressure difference of 290 mbar. Power is 4 kW, and sound pressure level is max 69 dB(A).
  • Amplifier A 1 02 11 021 SV: Max output power is 15000 VARMS, frequency range is DC - 5 kHz, and voltage max is ±212 VRMS. Total harmonic distortion is < 0.2 %RMS.
Scope of Delivery
  • Includes vibration exciter 4 kN, trunnion mount, power amplifier 15 kVA, cooling blower, connection cables, and hoses.
Options and Features
  • Options include different thread inserts, low degaussing kit, Squeak&Rattle operation, wheels and rails, thermobarrier, remote control, silencer, acoustic enclosure, and cable extension.
  • Features include vibration isolation < 6 Hz, automatic pneumatic load compensation, automatic armature centering, and a degauss kit.
Recommendations and Limitations
  • For long-term tests, reduce load to 80% to prevent damage. Continuous operation at maximum load is not recommended.
See more

Catalog excerpts

TV 55240/LS-340-1

S 55240/LS-340 (Example drawing) Dimensions in mm ø520 ø340 TECHNICAL PARAMETERS Vibration exciter S 55240/LS-340 4000/3600/12000 N 2 - 3000 Hz >2700 Hz 50.8 mm 2.0/2.0/2.4 m/s 50/45/130 g 50 N/mm 8.3 kg 250 kg 780 kg <1.5/<0.8 mT 340 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. GmbH © TIRA GmbH • Version 08 - 2021-09-13 Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction up to 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 15 - 23 dB(A)) Cable extension Factory acceptance test Scope of delivery: Vibration exciter 4 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø60 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks Vibration Test Syste

 Open the catalog to page 1
TV 55240/LS-340-2

TECHNICAL PARAMETERS Cooling blower TB 0310 Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Volume flow rate Total pressure difference Power Frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Sound pressure level, max. Power supply (standard)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.