video corpo

TV 55240/LS-340
2Pages

{{requestButtons}}

Catalog excerpts

TV 55240/LS-340 - 1

S 55240/LS-340 (Example drawing) Dimensions in mm ø520 ø340 TECHNICAL PARAMETERS Vibration exciter S 55240/LS-340 4000/3600/12000 N 2 - 3000 Hz >2700 Hz 50.8 mm 2.0/2.0/2.4 m/s 50/45/130 g 50 N/mm 8.3 kg 250 kg 780 kg <1.5/<0.8 mT 340 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. GmbH © TIRA GmbH • Version 08 - 2021-09-13 Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction up to 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 15 - 23 dB(A)) Cable extension Factory acceptance test Scope of delivery: Vibration exciter 4 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø60 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: st@tira-gmbh.de Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks Vibration Test Syste

Open the catalog to page 1
TV 55240/LS-340 - 2

TECHNICAL PARAMETERS Cooling blower TB 0310 Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Volume flow rate Total pressure difference Power Frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Sound pressure level, max. Power supply...

Open the catalog to page 2

All TIRA GmbH catalogs and technical brochures

  1. TV 50350-120

    2 Pages