Technical Parameters
  • Vibration Exciter S 51010/LS-340: Rated peak force for Sine/Random/Shock is 11000/11000/33000 Npk RMS pk. Frequency range is 2 - 3000 Hz with a main resonance frequency of >2400 Hz. Maximum displacement is 50.8 mm, and maximum velocity for Sine/Random/Shock is 2.0/2.0/3.0 m/s. Maximum acceleration is 85/70/200 g. The system has a suspension stiffness of 75 N/mm and an effective moving mass of 14 kg. Maximum payload is 250 kg, and total mass is 1100 kg.
  • Cooling Blower TB 120 FUK: Maximum volume flow rate is 1500 m³/h with a total pressure difference of 10.2 kPa. Motor output is 5.5 kW, and maximum frequency is 100 Hz. The hose diameter is 140 mm, and standard hose length is 5 m. Total mass is 61 kg, and dimensions are 487 x 637 x 487 mm. Maximum sound pressure level is 102 dB(A).
  • Amplifier A 1 02 11 021 SV: Maximum output power is 15000 VARMS with a frequency range of DC - 5 kHz. Maximum voltage is ±212 VRMS, and current is 40-100 ARMS. Signal input voltage is 10 VRMS with a total harmonic distortion of < 0.2 %RMS. Signal to noise ratio is > 80 dB. Total mass is 330 kg, and dimensions are 600 x 1740 x 800 mm.
Scope of Delivery and Options
  • Includes vibration exciter, trunnion mount, power amplifier, cooling blower, connection cables, and hoses.
  • Options include different thread inserts, low degaussing kit, silent operation, wheels and rails, thermobarrier, climatic chamber support, remote control, silencer, acoustic enclosure, cable extension, and factory acceptance test.
Features
  • Vibration isolation < 6 Hz, automatic pneumatic load compensation, automatic armature centering, and degauss kit to reduce stray magnetic field.
  • Integrated field supply, variable field voltage/current, mains switch, integrated line filter, and color touch screen.
Recommendations and Limitations
  • For long-term tests, reduce load to 80% to prevent damage. Continuous operation at maximum load is not recommended.
  • Ensure proper interlocks for field coil temperature, displacement, cooling air, overcurrent, and compressed air.
See more

Catalog excerpts

TV 51010/LS-340-1

S 51010/LS-340 (Example drawing) Dimensions in mm Ø650 Ø340 TECHNICAL PARAMETERS Vibration exciter S 51010/LS-340 11000/11000/33000 N 2 - 3000 Hz >2400 Hz 50.8 mm 2.0/2.0/3.0 m/s 85/70/200 g 75 N/mm 14 kg 250 kg 1100 kg <1.5/<0.8 mT 340 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 11 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø140 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) GmbH © TIRA GmbH • Version 11 - 2021-09-13 Options: Different thread inserts in the armature at customer request Low degaussing kit to further reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Wheels&Rails (incl. 3m rails) Thermobarrier (-40°C to +140°C) Chamber leadthrough Climatic chamber support kit Remote control (Software) Silencer for cooling blower (Noise reduction 3 - 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 5 - 23 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) ASM-Mode (Auto Shutdown Manager) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Degauss kit to reduce stray magnetic field Made in Germany Servicehotline Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field Std./low degaussing3 Armature diameter Min. required compressed air supply Interlocks

 Open the catalog to page 1
TV 51010/LS-340-2

TECHNICAL PARAMETERS Cooling blower TB 120 FUK Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Max. volume flow rate Total pressure difference Motor output Max. frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Max. sound pressure level...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.