Technical Parameters:
The Vibration Test System TV 50350/LS-120 features a vibration exciter with a rated peak force of 2700 Npk for sine, 2000 Npk for random, and 5300 Npk for shock. It operates within a frequency range of 2 to 4500 Hz and has a main resonance frequency greater than 3700 Hz. The system allows a maximum displacement of 45.0 mm peak-to-peak and a maximum velocity of 1.5 m/s for sine and random, and 2.5 m/s for shock. The maximum acceleration is 95 g for sine, 73 g for random, and 160 g for shock. The system supports a maximum payload of 25 kg and has a total mass of 280 kg.

Scope of Delivery:
The system includes a vibration exciter with a 2.7 kN force, a trunnion mount, a 15 kVA power amplifier, a cooling blower, connection cables, and a blower hose. Optional features include different thread inserts, a degauss kit, silent operation mode, a thermobarrier, remote control software, and noise reduction solutions.

Cooling Blower TB 0310:
The cooling blower has a maximum volume flow rate of 315 m³/h and a total pressure difference of 290 mbar. It operates at 4 kW and 50 Hz, with a hose diameter of 60 mm and a standard length of 5 m. The blower's sound pressure level is a maximum of 69 dB(A). Optional noise reduction solutions include a silencer and an acoustic enclosure.

Amplifier A 1 02 11 021 T SV:
The amplifier provides a maximum output power of 15000 VARMS and operates within a frequency range of DC to 5 kHz. It supports a maximum voltage of ±212 VRMS and a current range of 40-100 ARMS. The amplifier features a signal-to-noise ratio greater than 80 dB and a total harmonic distortion of less than 0.2% RMS. It includes interlocks for overload, temperature, displacement, cooling air, phase monitoring, and emergency stop.

Features:
The system includes vibration isolation below 6 Hz, a coarse filter unit, fully automatic electronic load compensation, electronic zero-point regulation with adjustable stiffness, and automatic centering of the armature. It is manufactured in Germany and includes a service hotline.
See more

Catalog excerpts

TV 50350/LS-120-1

S 50350/LS-120 (Example drawing) Dimensions in mm 508 TECHNICAL PARAMETERS Vibration exciter S 50350/LS-120 2700/2000/5300 N 2 - 4500 Hz >3700 Hz 45.0 mm 1.5/1.5/2.5 m/s 95/73/160 g electronically adjusted 2.9 kg 25 kg 280 kg <8.5/<1.4 mT 120 mm Field coil temperature, displacement, cooling air, overcurrent 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) Impact by moving to static mass and frequency is possible 4) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 2.7 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø60 mm (5 m) GmbH © TIRA GmbH • Version 08 - 2021-09-13 Options: Different thread inserts in the armature at customer request Degauss kit to reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Thermobarrier (-40°C to +140°C) Chamber leadthrough Remote control (Software) ASM-Mode (Auto Shutdown Manager) Silencer for cooling blower (Noise reduction up to 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 15 - 23 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic electronic load compensation Electronic zero point regulation with adjustable stiffness Automatic centering of the armature Made in Germany Servicehotline Armature (Standard) Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak3 Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload Total mass Magn. stray field without/with degaussing4 Armature diameter Interlocks Vibration Test Syste

 Open the catalog to page 1
TV 50350/LS-120-2

TECHNICAL PARAMETERS Cooling blower TB 0310 Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Volume flow rate Total pressure difference Power Frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Sound pressure level, max. Power supply (standard)...

 Open the catalog to page 2