1. Catalogs
  2. TIRA GmbH
  3. TV 50350-120
video corpo

TV 50350-120

TV 50350-120

TV 50350-120

Product catalog summary
Technical Parameters - Vibration Exciter S 50350-120
  • Rated Peak Force: Sine/Random/Shock - 2700/2000/5500 Npk RMS pk
  • Frequency Range: 2 - 4500 Hz
  • Main Resonance Frequency: >3800 Hz
  • Max Displacement: 25.4 mm Peak-Peak
  • Max Velocity: Sine/Random/Shock - 1.5/1.5/2.5 m/s
  • Max Acceleration: Sine/Random/Shock - 110/70/180 g
  • Suspension Stiffness: 22 N/mm
  • Effective Moving Mass: 2.7 kg
  • Max Payload Mass: 25 kg
  • Total Mass: 280 kg
  • Magnetic Stray Field: <8.5/<1.4 mT
  • Armature Diameter: 120 mm
  • Compressed Air Supply: 600 kPa
  • Interlocks: Field coil temperature, displacement, cooling air, overcurrent, compressed air
Scope of Delivery
  • Vibration exciter 2.7 kN
  • Trunnion mount
  • Power amplifier 15 kVA
  • Cooling blower
  • Connection cable (5 m)
  • Power cable (5 m) for amplifier (CEE 32 connector)
  • Blower hose ø60 mm (5 m)
  • Compressed-air hose NW 7.2 (Standard) (3 m)
Options
  • Different thread inserts in the armature
  • Degauss kit to reduce stray magnetic field
  • Squeak&Rattle (Silent operation without blower)
  • Thermobarrier (-40°C to +140°C)
  • Chamber leadthrough
  • Remote control (Software)
  • ASM-Mode (Auto Shutdown Manager)
  • Silencer for cooling blower (Noise reduction up to 6 dB(A))
  • Acoustic enclosure for cooling blower (Noise reduction 15 - 23 dB(A))
  • Cable extension
  • Factory acceptance test
  • Operation with temperature-controlled cooling blower (and optional with variable field strength)
Features
  • Vibration isolation < 6 Hz
  • Coarse filter unit
  • Fully automatic pneumatic load compensation
  • Automatic centering of the armature
  • Made in Germany
  • Service hotline
Technical Parameters - Amplifier A 1 02 11 021 SV
  • Max Output Power: 15000 VARMS
  • Frequency Range: DC - 5 kHz
  • Voltage, Max: ±212 VRMS
  • Current, Max: 40-100 ARMS
  • Signal Input Voltage: 10 VRMS
  • Total Harmonic Distortion: < 0.2 %RMS
  • Signal to Noise Ratio: > 80 dB
  • Field Voltage: 140-280 V
  • Field Current: 6-8 A
  • Total Mass: 330 kg
  • Dimensions: 600 x 1740 x 800 mm
  • Power Supply: 3~ / N / PE 400 V±5% 50 Hz, CEE 32
  • Recommended Fuse Protection: 32 A slow
  • Max Power Consumption: 17 kVA
  • Interlocks: Overload, Temperature, Displacement, Cooling air, Compressed air, Phase monitoring, Emergency stop
Features
  • Field supply integrated
  • Field voltage/Field current variable according to customer spec.
  • 4 Sigma peak current
  • Mains switch and integrated line filter
  • Color Touch Screen
Technical Parameters - Cooling Blower TB 0310
  • Volume Flow Rate: max. 315 m³/h
  • Total Pressure Difference: max. 290 mbar
  • Power: 4 kW
  • Frequency: 50 Hz
  • Hose Diameter: 60 mm
  • Hose Length: 5 m
  • Total Mass: 42 kg
  • Dimensions: 382 x 384 x 432 mm
  • Sound Pressure Level: max. 69 dB(A)
  • Power Supply: by amplifier rack
  • Max Current Consumption: 7.2 A
Options
  • Silencer TB 0310-SI (Noise reduction up to 6 dB(A))
  • Acoustic enclosure TB 0310-AE (Noise reduction 15 - 23 dB(A))
  • Hose length according to customer's request (up to 10 m)
See more

Catalog excerpts

TV 50350-120-1

S 50350-120 (Example drawing) Dimensions in mm 508 TECHNICAL PARAMETERS Vibration exciter S 50350-120 2700/2000/5500 N 2 - 4500 Hz >3800 Hz 25.4 mm 1.5/1.5/2.5 m/s 110/70/180 g 22 N/mm 2.7 kg 25 kg 280 kg <8.5/<1.4 mT 120 mm 600 kPa Field coil temperature, displacement, cooling air, overcurrent, compressed air 1) Random force according to ISO 5344:2004 2) Theoretical maximum shock value. Depends on payload, amplifier, shock and shock width 3) measured at 150 mm above armature For long-term tests, the load must be reduced to 80 %. Continuous operation at maximum load can cause damage. SCOPE OF DELIVERY, OPTIONS AND FEATURES OF THE SYSTEM Scope of delivery: Vibration exciter 2.7 kN Trunnion mount Power amplifier 15 kVA Cooling blower Connection cable (5 m) Power cable (5 m) for amplifier (CEE 32 connector) Blower hose ø60 mm (5 m) Compressed-air hose NW 7,2 (Standard) (3 m) GmbH © TIRA GmbH • Version 08 - 2021-09-13 Options: Different thread inserts in the armature at customer request Degauss kit to reduce stray magnetic field Squeak&Rattle (Silent operation without blower) Thermobarrier (-40°C to +140°C) Chamber leadthrough Remote control (Software) ASM-Mode (Auto Shutdown Manager) Silencer for cooling blower (Noise reduction up to 6 dB(A)) Acoustic enclosure for cooling blower (Noise reduction 15 - 23 dB(A)) Cable extension Factory acceptance test Energy Management System Operation with temperature-controlled cooling blower (and optional with variable field strength) Features: Vibration isolation < 6 Hz Coarse filter unit Fully automatic pneumatic load compensation Automatic centering of the armature Made in Germany Servicehotline Armature (Standard) Eisfelder Str. 23/25, 96528 Schalkau, Germany • Tel.: +49 36766 280-0 • Fax: +49 36766 280-99 • Internet: www.tira-gmbh.de • Email: [email protected] Subject to modifications TIRA Vibration Test Systems Rated peak force Sinepk/RandomRMS1/Shockpk2 Frequency range Main resonance frequency Max. displacement Peak-Peak Max. velocity Sine/Random/Shock Max. acceleration Sine/Random/Shock Suspension stiffness Effective moving mass (±5%) Max. payload mass Total mass Magn. stray field without/with degaussing3 Armature diameter Min. required compressed air supply Interlocks

 Open the catalog to page 1
TV 50350-120-2

TECHNICAL PARAMETERS Cooling blower TB 0310 Max. output powerRMS (factory-set) Frequency range VoltageRMS, max. CurrentRMS, max. (factory-set) Signal input voltageRMS Total Harmonic Distortion (at 70ARMS, 200 Hz) Signal to noise ratio Field voltage (factory-set) Field current (factory-set) Total mass Dimensions (WxHxD) Power supply (Standard) Recommended fuse protection Max. power consumption at 400 V (incl. blower) Interlocks: Volume flow rate Total pressure difference Power Frequency Hose diameter Hose length (Std.) Total mass Dimensions (WxHxD) Sound pressure level, max. Power supply (standard)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.