Catalog excerpts
Tinius Olsen Horizon Software Materials testing, analysis and reporting software
Open the catalog to page 1Key features • Multilingual • Method Editor • Result Editor • Multifaceted security • Touchscreen enabled* * Requires Windows 8 operating system and a touchscreen. • Test Method Library • Test Editor • Tabbed Test and Recall Area • Multiple Machine Control • Output Editor Tinius Olsen is proud to introduce the next evolution of testing software with our Horizon package. As part of our development process, we have taken the best features of our existing software offerings, including Test Navigator, QMat, and EP600 software, added a host of report writing and data manipulation capabilities...
Open the catalog to page 2METHOD LIBRARY AND TEST AREA f your testing regimen follows a quality control analysis to a variety of international standards, then the Test Method Library is probably the first place you will want to visit. Here you can select your desired test method, which has been written in accordance with different international test standards. For exam le, if you need to test for p the melt flow index of incoming resin to ASTM D1238 procedure B, you only need to select that routine from the list in the library. Similarly, if you need to determine the pipe crush strength in accordance with EN802,...
Open the catalog to page 3TABBED TEST AND RECALL AREA he next feature you may notice is that Horizon can perform multiple tests at one time, controlling and gathering test data from multiple machines (assuming that your PC has the necessary hardware to control multiple machines). This is true whether you’re controlling and gathering data from multiple melt indexers, hydraulic tensile testing machines; and/or electromechanical testing machines – whether they’re performing tensile, compression, flexural, tear, peel, or other tests. Test screen showing the tab labeled for multiple MP1200 melt Indexers The software is...
Open the catalog to page 4RESULT EDITOR AND OUTPUT EDITOR ultiple, differ nt graphs can e be produced per test, using different measurement axes. Once all the data has been gathered, Horizon can consolidate it into reports that you can customize to your or your customer’s individual needs. The output editor allows unprec dented formatting of your e data. You can select what live data can be shown during the test; the acceptable limits of the results; the graphical representation of the test, in multiple formats; the layout of the report including the use of your or your customer’s logo; and export or convert the...
Open the catalog to page 5Result Screen Tabs allow the generation of a single test report for each specimen, and also a summary test report. On each report, individual results from drop-down lists, including operator generated results, can be selected for display. Graph result Set-up allows axes to be defined along with the size and location of the graph(s). Insert your or your customer's logo As with all sections, the size and location of this section is user defined. Address and/ or identification label or title of the report Results Area Choose which results to display and report on the single test report. These...
Open the catalog to page 6HELP DESK AND SUPPORT orizon is one of the most technologically advanced testing software suites but it has retained the two key criteria of value and simplicity throughout the development process. If you have any questions on the operation of the software or how to generate different reports, the program provides built-in tutorials, on-line help and access to the Tinius Olsen Help Desk. Help Desk launch page From here you can access on-disk/on-line tutorials, details of the program key, and email our manned Help Desk. You can also access Team Viewer, which allows our software engineers to...
Open the catalog to page 7REPORT GENERATION HARDWARE REQUIREMENTS ●● 2GHz Pentium Dual Core or better. ●● 8GB RAM: One USB port for use with the software key (required). Ports required for each measuring device, barcode scanner, etc. One USB port and one display port if using touchscreen purchased from Tinius Olsen. Using multiple testing machines may require additional memory and/or a faster processor. 32-bit systems are limited to a maximum of 4GB, of which only 3.25GB is available due to system overheads. 512MB DirectX 10.0 capable video card or better. ●● DVD-ROM drive (to run installation DVD). ●● ouse or...
Open the catalog to page 8Plastic Impact
Open the catalog to page 10Tinius Olsen Tinius Olsen Automated Testing Systems PRODUCTIVITY More tests with increased accuracy FLEXIBILITY Complete automated testing solutions REPEATABILITY Automated systems that run all day and all night www.tiniusolsen.com sales@tiniusolsen.com
Open the catalog to page 11Materials testing, analysis and reporting software www.tiniusolsen.com info@tiniusolsen.com • Horsham, PA, USA • Redhill, Surrey, UK • Noida, UP, India • Shanghai, PR China Tinius Olsen
Open the catalog to page 12All Tinius Olsen catalogs and technical brochures
-
Indentation Hardness Testers
16 Pages
-
ST Series
8 Pages
-
Model MP1200 Melt Indexers
8 Pages
-
MODEL HMC 2.0
2 Pages
-
HDTM Series
5 Pages