Product Segments • Care Motion TA36 is one of our new generation medical actuators. It can lift up to 10000N and its IP rating is up to IP66W. The zero backlash design is stable and can be applied to various medical applications. The TA36 is suitable for operating beds or high-load patient lift systems. General Features Hall sensors Manual release (for patient hoist) 12/24/36V DC; 24V DC (PTC) Max. speed at max. load Max. speed at no load Retracted length IP rating Certificate Stroke Output signals Options Voltage Color Operational temperature range at full performance Suitable for patient hoist application
Open the catalog to page 1Standard Dimensions (mm) Load and Speed CODE Load (N) Push Pull Self Locking Force (N) No Load With Load No Load With Load 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 The current & speed in table are tested when the actuator is extending under push load. 4 The current & speed in table and diagram are tested with TiMOTION control boxes, and there will be around 10% tolerance depending on different models...
Open the catalog to page 2Motor Speed (4300RPM long motor, Duty cycle 10%) Speed vs. Load 40.0 35.0 30.0 Performance Data (24V DC Motor)
Open the catalog to page 3Load and Speed See page 2 Retracted Length (mm) See page 7 Rear Attachment (mm) See page 8 Direction of Rear Attachment (Counterclockwise) C = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing B = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 12.2 C = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 10.2, with plastic T-bushing Special Functions for Spindle SubAssembly 0 = Without (Standard) 2 = Standard push only 1 = Safety nut 3 = Standard push only + safety nut Output Signals 1 = Two switches at full retracted / extended positions to cut current...
Open the catalog to page 4Direction of Rear Attachment (Counterclockwise) 1 = Aluminum casting, no slot, hole 10.0 2 = Aluminum casting, no slot, hole 12.0 5 = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 10.0 6 = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 12.0 7 = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 10.0 8 = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 12.0 1 = Aluminum CNC, no slot, hole 10.0 7 = Iron CNC, clevis U, slot 8.2, depth 17.0, hole 10.0 2 = Aluminum CNC, no slot, hole 12.0 8 = Iron CNC, clevis U, slot 8.2, depth 17.0, hole 12.0 5 = Iron CNC, clevis U, slot...
Open the catalog to page 5Load and Speed See page 2 Retracted Length (mm) See page 7 Rear Attachment (mm) See page 8 C = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing F = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, for manual release I = Aluminum casting, U clevis, slot 8.2, depth 39.0, hole 10.2, with plastic T-bushing, for manual release G = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, Without press down for manual release Direction of Rear Attachment (Counterclockwise) Special Functions for Spindle...
Open the catalog to page 6qo t moTion Retracted Length (mm) 2. Retracted length needs to > Stroke + Y A. Front Attachment CODE Patient Hoist B. Load V.S. Stroke Stroke (mm) Load (N) General Patient Hoist
Open the catalog to page 7TA36 Ordering Key Appendix Rear Attachment (mm) 2 = Aluminum casting, no slot, hole 12.0 6 = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 12.0 5 = Aluminum casting, clevis U, slot 6.2, depth 17.0, hole 10.0 1 = Aluminum casting, no slot, hole 10.0 7 = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 10.0 8 = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 12.0 C = Aluminum casting, clevis U, slot 8.2, depth 17.0, hole 10.2, T bush 2 = Aluminum CNC, no slot, hole 12.0 5 = Iron CNC, clevis U, slot 6.2, depth 17.0, hole 10.0 6 = Iron CNC, clevis U, slot 6.2, depth 17.0, hole...
Open the catalog to page 8TA36 Ordering Key AppendixFront Attachment (mm) K = Iron, rod end bearing, no slot, hole 10.0 F = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, for manual release I = Aluminum casting, U clevis, slot 8.2, depth 39.0, hole 10.2, with plastic T-bushing, for manual release G = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, Without press down for manual release Direction of Rear Attachment (Counterclockwise) 1 = 0° 3 = 90° Functions for Limit Switches Wire Definitions CODE Pin • 1 (Green) 2 (Red) O 3 (White) 4 (Black) 5...
Open the catalog to page 9TA36 Ordering Key Appendix Connector 1 = DIN 6P, 90° plug P = Molex 8P, 90° plug, without anti-clip Terms of Use The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject to change without prior notice.
Open the catalog to page 1010 Pages
12 Pages
5 Pages
7 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
9 Pages
5 Pages
8 Pages
6 Pages
9 Pages
11 Pages
9 Pages
6 Pages
8 Pages
13 Pages
8 Pages
8 Pages
6 Pages
6 Pages
12 Pages
4 Pages
6 Pages
8 Pages
8 Pages
10 Pages
8 Pages
9 Pages
7 Pages
8 Pages
11 Pages
10 Pages
7 Pages
8 Pages
27 Pages
11 Pages
6 Pages
92 Pages
76 Pages
32 Pages
40 Pages
8 Pages
14 Pages
8 Pages
6 Pages
3 Pages
6 Pages
7 Pages
6 Pages
6 Pages
8 Pages
6 Pages
7 Pages
4 Pages
3 Pages
7 Pages
4 Pages
8 Pages
12 Pages
6 Pages
9 Pages
11 Pages
7 Pages
10 Pages
12 Pages
7 Pages
7 Pages
4 Pages
7 Pages
9 Pages
5 Pages
5 Pages
5 Pages
6 Pages
5 Pages
5 Pages
5 Pages
5 Pages
6 Pages
12 Pages
5 Pages
5 Pages
7 Pages
6 Pages
7 Pages
7 Pages
36 Pages
88 Pages
64 Pages
28 Pages
28 Pages
72 Pages
32 Pages
72 Pages
44 Pages
56 Pages