Product Segments • Care Motion TiMOTION's TA12 series linear actuator is designed primarily for high-load patient lifts and bariatric beds. These sensitive applications require a linear actuator whose design is focused on safety, reliability and effortless operation. A significant feature of the TA12 is the manual release function that allows for lowering of the patient in the event of an emergency or electrical power outage. The TA12 linear actuator has obtained the IEC60601-1 certification. General Features Max. load Retracted length Output signals Safety nut, quick release, manual release 12/24V DC (PTC); 24V DC (thermal protector, for patient hoist) Black, grey Operational temperature range Suitable for patient hoist application
Open the catalog to page 1Load and Speed CODE Load (N) Push Pull Self Locking Force (N) No Load With Load No Load With Load Motor Speed (3800RPM, Duty Cycle 10%) Motor Speed (3000RPM, Duty Cycle 10%) 1 Please refer to the approved drawing for the final authentic value. 2 This self-locking force level is reached only when a short circuit is applied on the terminals of the motor. All the TiMOTION control boxes have this feature built-in. 3 Operational temperature range at full performance: +5°C~+45°C 4 The current & speed in table are tested when the actuator is extending under push load. 5 The current & speed in table...
Open the catalog to page 2Motor Speed (3800RPM, Duty Cycle 10%) Speed vs. Load 60.0 Performance Data (24V DC Motor)
Open the catalog to page 3Motor Speed (3000RPM, Duty Cycle 10%) Speed vs. Load 60.0 Performance Data (24V DC Motor)
Open the catalog to page 4Direction of Rear Attachment (Counterclockwise) See page 9 Color 1 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing 2 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 12.2 6 = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 10.2, for load < 8000N 7 = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 12.2, for load < 8000N C = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing, for load < 8000N 1 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing 2 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole...
Open the catalog to page 5TA12 Patient Hoist Ordering Key TA12 Rear Attachment (mm) See page 8 C = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing Front Attachment (mm) See page 8 F = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, for manual release I = Aluminum casting, U clevis, slot 8.2, depth 39.0, hole 10.2, with plastic T-bushing, for manual release G = Aluminum casting, U clevis, slot 8.2, depth 19.0, hole 10.2, with plastic T-bushing, Without press down for manual release Direction of Rear Attachment (Counterclockwise) See page 9 Emergency...
Open the catalog to page 6CODE General Stroke (mm) General For Patient Hoist * For stroke over 400mm, + 10mm for each increment of 50mm stroke. C. Spindle Sub-Assembly (Push Only) CODE General For Patient Hoist
Open the catalog to page 7TA12 Ordering Key Appendix 2 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 12.2 Rear Attachment (mm) 1 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing 6 = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 10.2, for load < 8000N 7 = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 12.2, for load < 8000N C = Aluminum casting, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing, for load < 8000N Front Attachment (mm) 1 = Iron CNC, U clevis, slot 8.2, depth 17.0, hole 10.2, with plastic T-bushing 2 = Iron CNC, U clevis, slot 8.2, depth 6 =...
Open the catalog to page 8TA12 Ordering Key AppendixDirection of Rear Attachment (Counterclockwise) 1 = 0° 3 = 90° Functions for Limit Switches Wire Definitions CODE Pin • 1 (Green) 2 (Red) O 3 (White) 4 (Black) 5 (Yellow) A (Blue) 1 extend (VDC+) N/A N/A N/A retract (VDC+) N/A 3 extend (VDC+) common upper limit switch N/A retract (VDC+) lower limit switch E = Molex 8P, plug F = DIN 6P, 180° plug, for TEC extension cable standard option P = Molex 8P, 90°plug, without Q = Molex 6P, 90° plug The user is responsible for determining the suitability of TiMOTION products for a specific application. TiMOTION products are subject...
Open the catalog to page 910 Pages
12 Pages
5 Pages
7 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
9 Pages
5 Pages
8 Pages
6 Pages
9 Pages
11 Pages
9 Pages
10 Pages
6 Pages
8 Pages
13 Pages
8 Pages
8 Pages
6 Pages
6 Pages
12 Pages
4 Pages
6 Pages
8 Pages
8 Pages
10 Pages
8 Pages
7 Pages
8 Pages
11 Pages
10 Pages
7 Pages
8 Pages
27 Pages
11 Pages
6 Pages
92 Pages
76 Pages
32 Pages
40 Pages
8 Pages
14 Pages
8 Pages
6 Pages
3 Pages
6 Pages
7 Pages
6 Pages
6 Pages
8 Pages
6 Pages
7 Pages
4 Pages
3 Pages
7 Pages
4 Pages
8 Pages
12 Pages
6 Pages
9 Pages
11 Pages
7 Pages
10 Pages
12 Pages
7 Pages
7 Pages
4 Pages
7 Pages
9 Pages
5 Pages
5 Pages
5 Pages
6 Pages
5 Pages
5 Pages
5 Pages
5 Pages
6 Pages
12 Pages
5 Pages
5 Pages
7 Pages
6 Pages
7 Pages
7 Pages
36 Pages
88 Pages
64 Pages
28 Pages
28 Pages
72 Pages
32 Pages
72 Pages
44 Pages
56 Pages