Catalog excerpts

SR1101-R-1

TimeLink microsystems ©(£)<&<§>©<& SR1101-R Redundant time-Code Amplifier-distributor Features The SR1101 redundant distributor provides analog IRIG B, time code amplification and distribution. The time codes are based on a 1 kHz (or 10 kHz) amplitude modulated (1/3,1/1) sine-wave carrier. The equipment is housing in a 1U rack mount unit. • 2 LED's (On and ALARM) shows if the equipment power supply is OK and if it switch in alarm. • 3 LED's associated with a push button shwos the different status : o AUTO : automatic selection of the source. o A or B : channel A, active A active, respectively B. The push button allows to manually select the operating mode of the equipment : A, B or automatic. If the LED A / B are red it signals the presence of non-input signal. Selection / Amplification time code: The equipment receives the analog signal input from 2 sources of IRIGB external time code. In AUTO position, the equipment automatically selects valid source. The signal is amplified and distributed over 10 outputs of the equipment. Settings : Each of the 10 outputs could be adjusted. The settings is: The gain of each output amplifier. The gain of each amplifier is adjusted by a dedicated potentiometer. All the input/outputs connectors are located on the rear face of the equipment. The power supply uses a fused standard 230V AC connector, CEE compliant, with filter & ONN/OFF switch. The analog time code signal connector is a base isolated female BNC. The input circuit impedance is 600 Q. Remote control The equipment can be remotely monitored and commanded through an Ethernet 10/100 Mbit/s connection using either standard HTTP or UDP protocols

 Open the catalog to page 1
SR1101-R-2

SR1101-R Redundant time-Code Amplifier-distributor Specifications Time code input: isolated BNC, 600 Q transfo or BR2. 1 kHz or 10 kHz amplitude modulated sine-wave carrier (1/3 1/1). Amplified code output: isolated BNC ( 600 Q transformer or BR2) adjustable output level The input accepts signals from +2 to 7 V peak-peak The outputs are identical to input level ± 1V peak-peak on 600 Q. • All outputs are isolated Width = 19" (481 mm), Height = 1U (44.5 mm), Depth 351 mm Weight: 3 Kg. Consumption: 20 W. MTBF = 63 000 h Ordering information SR1101 - R BNC connectors - 10 outputs Information’s contained...

 Open the catalog to page 2

All TimeLink microsystems catalogs and technical brochures

  1. TMG5000

    2  Pages

  2. TMF1512

    2  Pages

  3. TMF1521

    2  Pages

  4. TMF1211

    2  Pages

  5. TMA2045

    2  Pages

  6. TMA2040

    2  Pages

  7. SR1256

    3  Pages

  8. SR1246

    3  Pages

  9. TMA1251

    3  Pages

  10. TMA1250

    3  Pages

  11. TMO3000-R/T

    2  Pages

  12. TMD2112

    2  Pages

  13. TMD1401

    2  Pages

  14. SR1101-1

    2  Pages

  15. SR2212

    2  Pages

  16. TMD1510

    2  Pages

  17. TMD2313

    2  Pages

  18. TMS2011

    2  Pages

  19. TMS2010

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.