1. Catalogs
  2. Time Electronics
  3. 5080 PAT Calibrator Data Sheet
video corpo

5080 PAT Calibrator Data Sheet

5080 PAT Calibrator Data Sheet

Product catalog summary
Description
The Time Electronics 5080 Portable Appliance Tester Calibrator (PATCAL) is a precision instrument designed for high accuracy calibration of portable appliance testers and insulation/continuity testers. It supports calibration functions for earth bond, insulation, leakage, touch leakage, and load tests. The device is portable, housed in a robust safety case, and battery-powered to ensure isolation and prevent inaccuracies from stray leakage. It features a safety interlock and an LCD display for voltage and current readings.

Specifications
  • Earth Bond: Calibrated low value resistive loads ranging from 20 mΩ to 18 Ω with varying accuracies. Open circuit voltage measurement range is 0 to 20 V with 0.25% accuracy.
  • Insulation: Calibrated high value resistive loads from 95 kΩ to 100 MΩ with accuracies from 0.1% to 1.0%. Open circuit voltage measurement range is 0 to 1 kV DC with 0.25% accuracy.
  • Leakage: Nominal leakage currents at 230 V AC range from 0.5 to 15 mA. Mains voltage measurement range is 0 to 500 V AC with 0.25% accuracy.
  • Touch Leakage: Constant current source of 1.9 mA AC for touch leakage meters with a measurement range of 0 to 2 mA AC.
  • Load Test: External load connection via IEC connector with mains voltage measurement range of 0 to 500 V AC and load current measurement range of 0 to 13 A AC.

Features
  • Calibration of PATs and VDE 0701 testers
  • Earth bond range from 18 Ω to 20 mΩ
  • Earth bond currents up to 50 A AC
  • Load test currents up to 13 A AC
  • Integral LCD digital meter for voltage and current display
  • Safety interlock feature
  • Battery operation with over 200 hours between charges
  • Portable and robust carrying case

Ordering Information
  • 5080: Portable Appliance Tester Calibrator (PATCAL)
  • C188: Traceable calibration certificate (Factory)
  • C135: Accredited calibration certificate (ISO 17025)
See more

Catalog excerpts

5080 PAT Calibrator Data Sheet-1

Time Electronics 5080 Portable Appliance Tester Calibrator (PATCAL) Description A precision calibrator designed to provide rapid high accuracy calibration of portable appliance testers and insulation/continuity testers. The 5080 has calibration functions for earth bond, insulation, leakage, touch leakage, and load test. It is a practical and simple operation instrument that can be utilsed in the lab as a calibration standard or as a mobile testing unit for site calibration work. Housed in a robust safety case the 5080 is easily portable, rugged and ideal for field use. It is battery powered, which ensures isolation and prevents inaccuracies due to stray leakage. Features include safety interlock that prevents contact with earth bond studs during insulation and leakage tests, and an LCD display for voltage and current. Features • For calibration of PATs and VDE 0701 testers • Earth bond range 18 Ω to 20 mΩ • Earth bond currents up to 50 A AC • Load test currents up to 13 A AC • V & I displayed on integral LCD digital meter • Safety interlock feature Earth Bond – Calibrated low value resistive loads • Battery operation (>200 hrs between charges) • Portable and robust carrying case Ordering information Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Time Electronics Ltd, Unit 5, T O N Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectr