TICO Resilient Seatings have been developed and used over many years for the control of relatively small movements within a structure. The high quality pad materials can be simply installed between virtually any combination of building material and provide an effective and economical means of separating mating surfaces to prevent damage from shrinkage, differential settlement, creep, rotation and thermally induced movements. These materials are dimensionally stable under widely varying atmospheric conditions and have been formulated from the highest quality constituents to ensure that they...

Open the catalog to page 3
TSB Resilent Seating - 5

Stress/Deflection Characteristics TICO CV/M/RS > 25 mm 12.5 mm 2 Shear Characteristics TICO CV/M/RS > Sample size 150 x 150 mmCompressive stress 2100 kN/m 2 25 mm12.5 mm6 mm Shear Deflection (mm) 0132476895 0123456 Shear Load (kN) Maximum Recommended Working Stress (kN/m > 2 ) 1400 These graphs have been prepared from the results of extensive testing over many years. Where appropriate, data has been presented in the form of a shadow graph to illustrate the effect of shape factor on performance of the pads. All data is presented for guidance only. Ultimate Breakdown Density (kg/m In excess...

Open the catalog to page 5
TSB Resilent Seating - 8

The selection of a particular seating material and thickness depends on a number of factors including: Operating loads (dead load and live loads) Available space to incorporate bearings Shape of bearing Degree and direction of movement required Degree of rotation required (if any) The first step in design is to establish a likely grade of material based on the generated stress caused by the applied load over the bearing area. For example, if a strip seating 100 mm wide is required to support a slab with an associated line load of 50 kN per linear metre of pad: In this instance, TICO CV/M/RS...

Open the catalog to page 8
TSB Resilent Seating - 9

Cast Concrete Shuttering TICO Resilient Seating Pads TICO S/WA TICO S/CO TICO MS/WA TICO Resilient Seating All joints sealed with TICO A/ST Sealing Tape TICO VF/PA Void Filler TICO Resilient Seating >

Open the catalog to page 9
TSB Resilent Seating - 10

On arrival on site, TICO Resilient Seatings should be stored away from direct sunlight, excessive heat, chemicals or any liquid media. They should be kept in a safe, secure location where they are unlikely to be damaged or tampered with, become immersed in water, or have other building materials stacked on top of them. Seatings should be handled with care during installation to ensure that they are not dropped or in any other way damaged. Damaged seatings should never be incorporated in the works and should be brought to the attention of the resident engineer or consultant.On no account...

Open the catalog to page 10
TSB Resilent Seating - 11

GradeStandard Thicknesses (mm)Standard Sizes (mm)Load Carrying Capacity (kN) * > TICO CV/D/RS TICO CV/PF/RS 6 1200 x 75 1395 12.5 1200 x 150 2790 25 1200 x 300 5580 1200 x 600 11,160 1200 x 1200 22,320 TICO CV/CA/RS 6 1200 x 50 18 12.5 1200 x 50 420 25 1200 x 100 840 1200 x 200 1680 1200 x 500 4200 1200 x 1000 8400 TICO CV/M/RS 12.5 1200 x 100 36 25 1200 x 200 72 1200 x 500 180 1200 x 1000 360 6 1200 x 50 84 12.5 1200 x 100 168 25 1200 x 200 336 1200 x 500 840 1200 x 1000 1680 > *Load carrying capacities are based on the maximum recommended working stress of each material under normal...

Open the catalog to page 11