GSZ2 Range Single Pole Normally Open DC Contactor
4Pages

{{requestButtons}}

Catalog excerpts

GSZ2 Range Single Pole Normally Open DC Contactor - 1

GSZ2 Range Single Pole Normally Open DC Contactor GSZ2 range single pole normally open DC contactor apply to starter-stop of battery vehicle and power switching and the uninterruptible power supply system of motor forkliftsN locomotivesN telecomm-unications and computer fields supply. The product design meet GB/T14048.1 " Low Voltage Switchgear and Control Equipment General" N Mechanical Department standards JB2286-78 "Basic Technical Conditions of Traction Electrical Device" N JB3974-85 "DC Electrical device of Battery Vehicle Basic Technica Conditions" and the Ministry of Posts YD/T585-92 " Distribution Equipment Communication Function" N YD/T512-92 " Telegram Power Equipment Technica Conditions" standard. ~» ig^RSX TYPE AND MEANING Coil voltage control specifications 12V, 24V, 48V - ommmm, smmmm D said that the single-coil, S said that the two-coi - DC-lf&§M3E!IfP^>]S DC-1 rated load current - Design serial number '- ^1flM>]rtSlfi4§§ Single pole DC contactor Enterprises code H, gSft&jg STRUCTURE FEATURE A mtwMftMM^, m%mm&; mf&xm-, iigv mm, m Direct action type, double breaking points; natural interrupt fire; small sizeN ightweightx lowpowerx consumptionx high reliability. WORKING CONDITION AND INSTALLATION WAY Ambient temperature: -25°C ~ +40°C, Average temperature ^35°C in 24H; Vibration frequency at fixed place: 1 ~50Hz (1 ~ 10Hz frequency, amplitude A ffuBSDiSS: 30m/s2 Impact acceleration: 30m/s2 A S;l>i75(S]: GEH Installation direction: free S:IS75it: KCTSilS Installation way: by screw A sffli^fij: ^mmTim CDC-D Adapt work rule: Ongoing work rule (DC-1)

Open the catalog to page 1
GSZ2 Range Single Pole Normally Open DC Contactor - 2

2u JS##f& ( SSI ) TECHNICAL PARAMETERS (AS TABLE 1) OUTLINE DIMENSIONS AND MOUNTING DIMENSIONS

Open the catalog to page 2
GSZ2 Range Single Pole Normally Open DC Contactor - 4

A. ill&mto ORDER REMARK A SM§SS5^SsSS^ Entire type of contactor A ^mm^&ME Voltage of control coil A illii Order volume Example: GSZ2-200S/48V single pole normally open DC contactor 10 sets. mm^±m%^mmmmh Dc-imsi^i^^ooA, siu^ffiTs Means: double coil control of normally open main contact, DC-1 load rated working current 200A, control voltage 48V, order volume 100sets.

Open the catalog to page 4

All Tianshui 213 Electrical Apparatus Group CO. catalogs and technical brochures

  1. GSW1

    33 Pages

  2. GSC3 series

    5 Pages

  3. GSB2

    4 Pages

  4. GSA1 Series

    15 Pages

  5. GSB2-32N

    3 Pages