GSU1 series surge protection device
1 / 5Pages

Catalog excerpts

GSU1 series surge protection device - 1

TIANSHUI 213 GSU1S8I GSU1 RangeElectricSurgeProtector ^ ffljj APPLICATION_ TN-C,TN-C-S^±±^fe, a*ilffi^Sia*׌iffSfo GSU1 Range ElectricSurge Protectorare mainlyused intheelectrical circuitwithAC50Hzor60Hz,380VanduptoTT\IT\TN-S,TN-CxTN-C-S power supply System and so on, power of lightning or over-voltage surge protection. CONFORM STANDS AND CERTIFICATION I f^iaflfrIXTfe/ʋ: Conformtothefollowingstanders: a GA173 (ammmm^mmwimm} (Computer Information System Security lightning) a IEC61 643-1.1 (EffiE^ra^SPDtt^SSWi^MSS) (SPD low-voltage distribution network performance requirements and test methods) a G B18802.1 < EffiE^^^ffi^)l^S^^(SPD)s-^^:14^SSWpMSS > (Low-voltage distribution System of surge protectors Part 1 : Performance requirements and test methods) GSU1 RangeElectricSurge Protector throughthe Ministryof Railways Product QualitySupervision, InspectionandTestingCenterandthe Beijing CenterforLightning Dtection DeviceTesting, madebythe Ministryof PublicSecurityissuedbythecomputerinformation System security products, spcial sales permit. =« SfSSf^TYPEANDMEANS GS U 1 □ / □ Annex (B for alarm, X for remote contact) ):Poles(seetable1) Thelargestcontinuous operatingvoltage (seetablel) Maximum discharge current (see table 1 Kt1~)5^ Design sriai number ^SS^S Electricsurgeprotector flMtf騮 Enterp rises code euntxmttmmtt WORKING CONDITION AND INSTALLATION CONDITION a SgQg^SH2000m;Elevation: «2000m a HSSn>mIt: ̌^!qS:-5°C~+40oC, jfS?QS : -40°C ~+70°C ; Environment temprature : the normal range:-5°C ~+40°C, to expend the scope of +70°C during -40°C.

Open the catalog to page 1
GSU1 series surge protection device - 2

??PDF.cdr table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:13.00pt "Arial", sans-serif; } .font6 { font:14.00pt "Arial", sans-serif; } .font7 { font:11.00pt "Arial Black", sans-serif; } .font8 { font:12.00pt "Arial Black", sans-serif; } .font9 { font:5.00pt "Franklin Gothic Medium", sans-serif; } .font10 { font:12.00pt "Franklin Gothic...

Open the catalog to page 2
GSU1 series surge protection device - 3

@TIANSHUI2I3 GSU1=K5'J|.Iffi#'f§ Note: nfortheSPDpole;1 P + N.3P+N with 2P,4Pofthe width of the same Picturel outlineand mountingdimensions t. WftANNEX ■ ﯮHlti^ Remote contact ^^»ac36v, ia, ^-^mmt,3^w$i௣$ln, mMcj, m^mmimBo Surge protectors to install remote-contact remote instruction function. Remote Contact Chang to open contacts, rated working conditions for AC36V, 1 A, when oneormoreofthemodulesmodulefails,closecontact, failure to submit information ■ SSSAlarm a ffi«g§AC22ov芯±±*, mm\%p^iEmTmmmjMB.&o ^>!g^g§^ mm, fwmmtiimmp, mf蠠miMLo gffl§±fa,mmp&it, mi mmm&, ^se^^^w, mm^m댻, mmm^mH;...

Open the catalog to page 3
GSU1 series surge protection device - 4

??PDF.cdr table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:10.00pt "Arial", sans-serif; } .font7 { font:11.00pt "Arial", sans-serif; } .font8 { font:12.00pt "Arial", sans-serif; } .font9 { font:13.00pt "Arial", sans-serif; } .font10 { font:14.00pt "Arial", sans-serif; } .font11 { font:18.00pt "Arial",...

Open the catalog to page 4
GSU1 series surge protection device - 5

SPDgrounding line application for more than 6mm2 copper wires to connect Surge protectors should be installe! in sries on the road supporting fuse or circuit breaker (see table 1 S驩ries models, see Figure 5 wiring), to avoid failureduetothe impact onthe entire power supplyline. Surge protectors as required after installation does not need to adjust automatically to the power grid protection. Opration, regular inspection module instructions window is red, in a timely mannerin order to replace the component failure. L L N L1 L2 L3 L1 L2 L3 N H(Picture)5 j%17S35SU ORDER NOTICE_ Users should be...

Open the catalog to page 5