GSM1 Series Moulded Case Circuit Breakers GSM1 series moulded case circuit breakers suitable for turn-on or turn-off not frequently and starting a motor not frequently in the circuit of AC50Hz, rated nsulation voltage up to 800V(GSM1 -63 is 500V), rated working voltage 690V or below(GSM1 -63 is 400V), rated working current up to 800A.The breakers of 4 poles are mainly suitable for cable short cuicuit protection,cable overload protection and turn-on or turn-off not frequently in the power supply system, mean while can open neutral conductor and leg conductor together as to keep from high electric potential transferring and protect operators.Besides having short cuicuit and overload protection for cuicuit and motor.the breakers can assembly many function modules such as under-voltage realease,shunt release,alarm contact , anxiliary contact,motor-driven operation device and so on,meeting all kinds of protection and control functions. ftStrii ( CONFORM TO STANDARDS ) The breakers comply with the demands of the following standards: Low-voltage switchgear and control gear: Low voltage breakers Low-voltage switchgear and control gear: Part 11 Low voltage breakers Code of N-pole(no code for 3 poles product): A or B Code for application: no code for power distribution 2 for motor protection Code for release pattern and inner accessories (see Table 1) The first digit stands for release pattern.The other twodigits stand for code of inner accessories 2 il^^l^rfjM () JK^0§§ Only has electromagnetic (instantaneous)type release 3:^z2j-E&fiM (Sit) JK^0§§ Thermo-electromagnetic (double) type release 3N 4 Codefor the pole number: 3^ 4 Wii^TjJ^'- Code for the operation means: ^;lflJilIclJill'/P7cft^ No code for handle operation dirrectly "P" ^z^JfUfp Power driven "Z" f^z^JE^filJ|{/pTuming handle Code for the breaking ability (No code for 4 poles product L-^)f=?£y typical type M-^M^MjW. second high breaking type H-r^]^}ifT§y hige breaking type ttW^%^Mf^^M Code for the frame grade l^vfj^^ Code for designation ■ 111145^^ ^I^SSi^ Moulded case circuit breakers fi^lM"^" Code for company

Open the catalog to page 1
GSM1 Series Moulded Case Circuit Breakers - 2

Table 1 :re I ease pattern and code for inner accessories Left mountinc Right mountinc Alarm contact Auxiliary contact Under-voltage release Shunt release Lead direction Alarm contact Shunt release Auxiliary contact Under-voltage release Shunt release Auxiliary contact Shunt release Auxiliary contact Under-voltage release Shunt release Alarm contact Auxiliary contact Alarm contact Under-voltage release Alarm contact Shunt release auxiliary contact alarm contact Two group of auxiliary contact alarm contact Under-voltage release auxiliary contact alarm contact A 2oo: mmim^mmum^m^; 3oo:...

Open the catalog to page 2
GSM1 Series Moulded Case Circuit Breakers - 3

For GSM1-400,630,800, codes 248,348,278,378 only have one pair of auxiliary contacts(a normal opened, a normal closed),but 268,368 have three pairs of auxiliary contacts. For the specification 6A of GSM1 - 63,only has short circuit. E9« XffEFlg ENVIRONMENT CONDITION FOR OPERAT the average of temperature not exceeding Relative humidity:not exceeding 50% at the maximum ambient temperature of +40.With lower temperature,higher humidity would be permitted, but the lowest average temperature in a month not exceeding +25°C during the most moist month,and the maximum monthly average relative...

Open the catalog to page 3
GSM1 Series Moulded Case Circuit Breakers - 4

A mmmyj^: mmmm cs$etg75S) mmmm-, mA^mm c^mmm According to the wiring met hod: Wiring in front of the board; Wiring on back of the board; Insertion type (including insertion type in front of the board and insertion type on back of the board, only GSM1-1 00,225,400L has the wiring method of insertion in front of the board) A mmtTjiZtt: ^mmmmt; m^mmt; wsfp According to the operation means:Handle operating directly Turning handle Power driven. According to the usage: Power distribution ; motor protection. A }f?|Ml$[£h H3IS According to the pole numbenThree poles;Four poles. According to the...

Open the catalog to page 4
GSM1 Series Moulded Case Circuit Breakers - 8

The heat state in the Table 3 and Table4 means the state after the breaker connects 1.051 n for formulated time starting from the cold state: f the ambient temperature is different from the formulated temperature in the test,can test as the correction current after the following current- temperature characteristic curve. Characteristic curve and current-temperature characteristic curve GSM 1 -63 current-temperature characteristic curve GSM1 -100 current-temperature characteristic curve |g(°C) Ambient temperature

Open the catalog to page 8
GSM1 Series Moulded Case Circuit Breakers - 9

GSM1 -225 current-temperature characteristic curve GSM 1 -630 current-temperature characteristic curve GSM1 -400 current-temperature characteristic curve GSM 1 -800 current-temperature characteristic curve OUTLINE DIMENSIONS AND MOUNTING DIMENSIONS Wiring in front of the board(GSM1 - 63U M,three poles and four poles) X-X, Y-Y^=WS\^^^\ X-X,Y-Yas the center of the breaker(three poles)

Open the catalog to page 9
GSM1 Series Moulded Case Circuit Breakers - 10

pane,wiring in front of the board Wiring on back of the board(GSM1-63U M.threepolesandfourpoles) X-X, Y-Y^g^SlfTSg^^lll,'! X-X,Y-Y as the center of the breakerfthree poles) panel, wiring on back of the board nsertion type on back of the board(GSM1 -63U M,three poles) X-X, Y-Y^=WS\^^^\ X-X,Y-Yas the center of the breaker(three poles) pane, wiring on back of the board

Open the catalog to page 10
GSM1 Series Moulded Case Circuit Breakers - 11

Wiring in front of the board(GSM1 -1 OOU M,three poles and four poles) X-X, Y-Y^=WS\^^^\ X-X,Y-Yas the center of the breaker(three poles) Wiring on back of the board(GSM1 -1 00U M,three poles and four poles) X-X, Y-Y^^S^jSSW X-X.Y-Y as the center of the breaker(three poles) panel, wiring on back of the board nsertion type on back of the board(GSM1 -100U M,three poles and four poles) X-X, Y-Y^=WS\^^^\ X-X.Y-Y as the center of the breaker(three poles) panel,wiring on back of the board

Open the catalog to page 11
GSM1 Series Moulded Case Circuit Breakers - 12

Insertion type in front of the board(GSM1 -100U M,three poles and four poles) X-X, Y-Y^=WS\^^^\ X-X.Y-Y as the center of the breaker(three poles) aperture dimensions of the suIm- panel,wiring in front of the board Wiring infrontoftheboard(GSM1-225U M,three poles and four poles) X-X, Y-Y^=WS\^^^\ X-X.Y-Y as the center of the breaker(three poles) panel, wiring on back of the board