Catalog excerpts

^ TIANSHUI 213 GSG1-100S5iJPlM5f5 GSG1-1005UPlgtf裣 GSG1 -100 Range Separated Switch . ffli APPLICATION GSG1-100 range separated switch (shortened form separated switch) mainly use in the electricity-distribution networks as the master switch of the power supply to break or make the circuits with loads. When it in switching-on status, it can take the normal working current as well as the specified faulty current within the specified time to ensure the power continuousness of the networks and circuits; while it is in the switching-off status, it can provide the reliable insulating gap to make the electricity-consumer equipment as well as the circuit to be isolated with the power supply and to prevent the electricity-consumer equipments from being damaged due to the over voltage and also ensure the safety maintenance working forthe electricity-consumer equipment. * ISWfjS STRUCTURAL FEATURES_ ■ rS^nlEC60947-3,GB14048.3^#)io Products accord with the IEC60947-3, GB14048.3 substances ■ HHCCCMLCEi.IE Through the CCC certification, the EU CE safety certification H» jjj^gggjTYPEANDMEANS_ gs g 1 -100 □ / □ -njSl) Poles(seetablel) - UAIfpE&Zn tl) Ratedcurrent(seetable1] - ^fˮ'Mffktf'M (lAlSl) Fevercurrentagreement(seetable1 ] -lS:i1~)5"j Design s˩riai number - Ppl^Fr:^ Insulateswitches -Enterprises code eu±&vtmmmmm) MAIN TECHNICAL PARAMETERS Isee table 1 )_ GSG1-100^511 PHgffﯣGS^tt8g#ifc GSG1-100rangeseparated switch maintechnical parameters s(table)1 MB item mm. parameters êa note U§ type GSG1-100 Usageclassification AC-22 Rated Insulationvoltage 415V
Open the catalog to page 1
^TIANSHUI2I3 GSG1-100S5!]PIM5f (SIS Continue on top of table) Ratedoperatingvoltage 240/415V il» Frequency 50/60HZ Conventionthermalcurrent 100A Rated operating current 32A,63A,100A «S Pôle 1,2,3,4® Rated ImpulseWithstand voltage 6000V Short-timewithstand current 20ie ItSMHis Time tolerancel s Rated short-circuitthe abilitytoconnect 301e S^Mi]3=o.is Making time 3=0.1s WmSSt&J Ratedabilitytoconnect 31e Breakingcapacityofrated limitshort-circuit 31e Thenumberofon-load opration 2000?? The numlSrfM^JIoperation 10000?? wiringcapacity 50mm2 WORKING CONDITION AND INSTALLATION CONDITION I...
Open the catalog to page 2
^TIANSHUI2I3 GSGI-lOOm^iJPISfl1* OUTLINE AND INSTALLATION DIMENSIONS Note:nispolenumber,polescancollect1 ps 2px 3pand4p t. ffiliftW OPERATING INSTRUCTION M; Terminal Blocks to be fastening wire, there does not allow loose, so that the wires and terminais to maintain good contact; The product is for maintenance-free type, does notallow users to open repair. A. iT&®m ORDER NOTICE fflpjswiiifiiaw^ffli§s «silo H50:GSG1-1OO 63A/3P Hgf^100o Users need attention the entitle type, character and volume of switch. Example:GSG1 -100 63A/3Pswitch 100sets
Open the catalog to page 3All Tianshui 213 Electrical Apparatus Group CO. catalogs and technical brochures
-
GSC2-F Range AC Contactor
5 Pages
-
CIRCUIT BREAKERS GSB1Z
3 Pages
-
GSW1
33 Pages
-
GSC1-4011 FC-6511 FC
4 Pages
-
GSC3 series
5 Pages
-
GSB2