GSB2
4Pages

{{requestButtons}}

Catalog excerpts

GSB2 - 1

GSB2 Range Miniature Circuit-Breaker GSB2 range mini-breakers are mainly used in AC 50Hz or 60Hz, rated voltage up to 41 5V, rated current up to 63A and below to protect the circuit equipments or devices and the similar purposes, it also has isolation functions. The breakers can be matched with accessories such as the auxiliary contacts, the alarming contacts, shunt trip etc. so as to supply the auxiliary signals and realize its remote breaking functions. SjUgjSjlRjMjElfg STANDARD AND CERTIFICATION Conform to the following standard: IEC60898-K GB 10963.1. A R^CCCMEx TLMAffis CEiMESCBtAffio The products are all through the CCC certification, the TUV certifications the EU CE safety certification and CB certification. BWHSEX TYPE AND MEANS_ -^^Hit^T-f^^ Electrical accessories code '-fiiWt Poles -ISSE^SH; Rated current -iSBtflMj^^M (Cg!5D) Instantaneous release type (C or D] Svt/JS^ Design serial number d\5yUfS8ij§ Miniature circuit breaker -ifelli/ft^ Enterprises code nstantaneous release type and applicable (as the following table) WORKING CONDITION AND INSTALLATION CONDITION

Open the catalog to page 1
GSB2 - 2

Environment temperature : -5°C ~ +40°C, the average hours of temperature exceeding +35°C during 24 hours. No exceeding 50% at the maximum ambient temperature of 40°C.with lower temperature, higher humidity would be permitted, for example ,with temperature 20°C, the humidity can exceed 90%.Take the special measure to the dews on the surface, which would appear due to temperature change Pollution protection: Grade 2 Products should be used in no significant impact and vibration place. A Sli^glJ III ; Installing categories: Class III nstalling condition: mounted byTH35-7.5 standard rail track...

Open the catalog to page 2
GSB2 - 3

OUTLINE AND INSTALLATION DIMENSIONS

Open the catalog to page 3
GSB2 - 4

TERMINAL OUTLINE AND INSTALLATION DIMENSIONS The one polex two polesx three poles and four poles of the breakers Dicture 4 terminal of the breakers In order you need attention the namex typex character and volume of the breaker and its accessory name. Example: the mini-breaker GSB2-D 50/3P OF2 800 sets Means: GSB2 range miniature breaker, instantaneous release is type D, rated current is 50A, three poles, added auxiliary contact, and 800 sets.

Open the catalog to page 4