ZWIN-TN1006
1 /1Page

ZWIN-TN1006

ZWIN-TN1006
1 /1Page

Catalog excerpts

ZWIN-TN1006-1

► PRODUCT INTRODUCTION The main purpose of the total nitrogen online automatic analyzer is to monitor nitrogen-containing compounds in various forms in water. In natural water and wastewater, nitrogen almost exists in the form of various nitrates, which are divided into nitrate nitrogen, nitrite nitrogen, ammonia nitrogen, and organic nitrogen (proteins, amino acids, etc.). They exist in the water environment and are the main indicators of eutrophication of water bodies. The total nitrogen automatic monitoring device is widely used in areas such as pollution monitoring points, surface water monitoring stations, river sections, and drinking water source monitoring stations. 1. The ten way valve with sapphire core has high wear resistance, strong acid and alkali resistance, organic solvent resistance, strong service life, and high stability; 2. Using a specially designed reference method, mild displacement and contamination of the digestion tank do not affect the measured values; 3. it has a waste liquid separation function, which enables the separate discharge of high concentration reaction waste liquid and low concentration cleaning solution, 4. It has a dynamic dilution function and can automatically adjust the release factor according to the range set on site: 5. It has built-in quality control functions such as spiked recovery, blank testing, standard sample verification, zero point verification, span verification, parallel sample testing, etc., and can be activated automatically, manually, and in close proximity; 6. Equipped with automaticfault diagnosis and abnormal information uploading and recording functions, such as component failure, over range alarm, over limit alarm, reagent shortage alarm, etc; 7. Equipped with overheat protection: If the heating temperature is too high, the heater will automatically shut down; 8. After abnormal reset and power failure, the instrument will automatically discharge residual reactants and return to its initial working state. Equipped with power on alarm function, the instrument will generate alarm information when powered on again after power failure, 9. It has the function of analyzing instrument process logs, recording measurement data, and storing alarm information. It records data calculation once per hour and can be stored for more than 3 years. It can also be quickly imported from a USB flash drive Provide data;

 Open the catalog to page 1

All Tianjin Zwinsoft Technology Co.,Ltd. catalogs and technical brochures

  1. ZWIN-AI

    3  Pages

  2. ZWIN-WOMS10

    1  Page

  3. ZWIN-TPN1006

    1  Page

  4. ZWIN-TP1006

    1  Page

  5. ZWIN-PMS06

    1  Page

  6. ZWIN-OIW1006

    1  Page

  7. ZWIN-MOWQM08

    1  Page

  8. ZWIN-MOWQM06

    1  Page

  9. ZWIN-LT1006

    1  Page

  10. ZWIN-GAS

    1  Page

  11. ZWIN-CONT06

    1  Page

  12. ZWIN- WQMS06

    1  Page

  13. 1.0

    1  Page

  14. ZWIN-FM1006

    2  Pages

  15. ZWIN-GM1006

    2  Pages

  16. ZWIN-MS06

    2  Pages

  17. ZWIN-DA06

    1  Page

  18. ZWIN-WS1006

    2  Pages

  19. ZWIN-AQMS08

    1  Page

  20. ZWIN-AQMS06

    1  Page

  21. ZWIN-PM08

    2  Pages

  22. ZWIN-PMS06

    2  Pages

  23. ZWIN-YYM06

    2  Pages

  24. ZWIN-YY06

    2  Pages

  25. ZWIN-YY08

    2  Pages

  26. PVOC06

    2  Pages

  27. ZWIN-FVOCs06

    1  Page

  28. ZWIN-PVOC06

    2  Pages

  29. ZWIN-DUST06

    1  Page

  30. ZWIN-YCB06

    1  Page

  31. ZWIN-AWA5688

    1  Page

  32. ZWIN-NS06

    4  Pages

  33. ZWIN-AQMS30

    3  Pages

  34. ZWIN-AQMS20

    2  Pages

  35. ZWIN-EC06

    4  Pages

  36. ZWIN-AQMS10-A

    2  Pages

  37. ZWIN-AQMSF06

    2  Pages

  38. ZWIN-AQMS06-M

    3  Pages

  39. ZWIN-AQMS06

    4  Pages

  40. AQMS650

    2  Pages

  41. CEMS06 2025

    2  Pages

  42. UV1006

    4  Pages

  43. AQMS-600

    1  Page

  44. AQMS-300

    1  Page

  45. AQMS-100

    4  Pages

  46. AQMS-200

    4  Pages

  47. AQMS550

    2  Pages

  48. AQMS-500

    1  Page

  49. AQMS450

    2  Pages

  50. ZWIN-HVS06

    2  Pages

  51. ZWIN-YCM06

    2  Pages

  52. ZWIN-YCB06

    2  Pages

  53. ZWIN-YC08

    2  Pages

  54. ZWIN-PMV06

    1  Page

  55. BAM1006—M

    2  Pages

  56. COD Brochure

    4  Pages

  57. PH Brochure

    3  Pages

  58. ZWIN-WD1006

    2  Pages

  59. ZWIN-WS1006

    2  Pages

  60. ZWIN-PMS06

    4  Pages

  61. AQMS-400

    6  Pages

  62. AQMS-600 2025

    6  Pages

  63. CEMS06

    4  Pages

  64. ZWIN-YC08

    2  Pages

  65. ZWIN-YC06

    2  Pages

  66. ZWIN-YCM06

    2  Pages

  67. ZWIN-Minimeta

    4  Pages

  68. ZWIN-SKY3000

    6  Pages

  69. ZWIN-AQMS1006

    4  Pages

  70. ZWIN-NH3

    4  Pages

  71. Zwin-CO06

    4  Pages

  72. ZWIN-H206

    4  Pages

  73. ZWIN-H2S06

    4  Pages

  74. ZWIN-PMV06

    1  Page

  75. ZWIN-PVOC06

    2  Pages

  76. dust monitor

    1  Page

  77. ZWIN-PM06

    1  Page

  78. ZWIN-AQMS10

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.