COD Brochure - 1

XwinSafj} Tianjin Zwinsoft Technology Co., Ltd ZWIN-COD1006 COD Detector

Open the catalog to page 1
COD Brochure - 2

• Introduction ZWIN-C0D1006 online analyzer adopts the principle of ultraviolet fluorescence method. According to the fluorescence characteristics of organic matter in water, the COD content can be calculated by the fluorescence intensity released under the excitation of ultraviolet LED. The sensor adopts dual optical path design, which can automatically compensate the turbidity in real time, eliminate the interference of turbidity to the measurement, and make the sensor more stable and reliable. The instrument does not need reagent, no pollution, more economical and environmentally...

Open the catalog to page 2
COD Brochure - 3

Standard SP13 aviation plug (6-core, male connector) is configured at cable end of the COD analyzer to connect with controller, as shown below. Note: when the plug is connected to the matching 6-core receptacle on the controller, it has directionality, and the white dot on the front end of the plug can be inserted corresponding to the white dot on the receptacle. The pin corresponding to the white dot is numbered 1 (the gap width at this position is wider than the other two gaps), and the number is from 2 to 6 in the counterclockwise direction. Sheet 1 -1 describes the pin numbers...

Open the catalog to page 3
COD Brochure - 4

Although the COD online analyzer is standard equipped with a self-cleaning brush, but bard working conditions will still cause the sensor to be stained and adhered. In order to ensure accurate measurement, cleaning is very important. Regularly cleaning the sensor contributes to the stability of the data. Maintenance Tasks Recommended maintenance frequency Cleaning Sensor Recommended to clean every 4-8 weeks Calibration Sensor Carry out maintenance schedule as required by competent authority 1 .Outer surface of the sensor: clean outer surface of the sensor with tap water. If there is still...

Open the catalog to page 4

All Tianjin Zwinsoft Technology Co. catalogs and technical brochures

  1. UV1006

    4 Pages

  2. AQMS550

    2 Pages

  3. AQMS650

    2 Pages

  4. AQMS-200

    4 Pages

  5. AQMS-100

    4 Pages

  6. PH Brochure

    3 Pages

  7. ZWIN-WD1006

    2 Pages

  8. ZWIN-WS1006

    2 Pages

  9. ZWIN-PMS06

    4 Pages

  10. AQMS-600

    1 Pages

  11. AQMS-500

    1 Pages

  12. AQMS-400

    1 Pages

  13. AQMS-300

    1 Pages

  14. AQMS-400

    6 Pages

  15. AQMS-300

    6 Pages

  16. AQMS-600

    6 Pages

  17. AQMS-500

    6 Pages

  18. ZWIN-AQMS20

    6 Pages

  19. ZWIN-AQMS06

    6 Pages

  20. CEMS06

    4 Pages

  21. ZWIN-AQMS06

    2 Pages

  22. ZWIN-AQMS06

    2 Pages

  23. ZWIN-AQMS06

    1 Pages

  24. ZWIN-YC08

    2 Pages

  25. ZWIN-YC08

    2 Pages

  26. ZWIN-YC06

    2 Pages

  27. CEMS06

    2 Pages

  28. ZWIN-YCM06

    2 Pages

  29. ZWIN-SKY3000

    6 Pages

  30. ZWIN-AWA5688

    4 Pages

  31. ZWIN-NH3

    4 Pages

  32. Zwin-CO06

    4 Pages

  33. ZWIN-H206

    4 Pages

  34. ZWIN-H2S06

    4 Pages

  35. ZWIN-PMV06

    1 Pages

  36. ZWIN-PVOC06

    2 Pages

  37. BAM1006

    6 Pages

  38. ZWIN-ZS06

    2 Pages

  39. dust monitor

    1 Pages

  40. ZWIN-PM06

    1 Pages

  41. ZWIN-YCM06

    1 Pages

  42. ZWIN-AQMS10

    1 Pages

  43. BAM1006

    2 Pages

  44. BAM1006

    3 Pages

  45. ZWIN-PM06

    7 Pages