PRO-N
16Pages

{{requestButtons}}

Catalog excerpts

PRO-N - 1

More communication Improved accuracy ^ Fast sampling rate More protective J Smart grid ready

Open the catalog to page 1
PRO-N - 2

Enhanced hardware for demanding applications The Extended is the Thytronic high level platform for the comprehensive protection in distribution networks, substations and industrial plants with any level of application: selective protection of feeders, power transformers, motors, generators, bank capacitors inside large industrial plants (Oil & Gas), metallurgy and paper industry and offshore installations. INNOVATIVE FEATURES More binary I/O without external expansion modules More communication ports with redundancy and TX (RJ45) and/or FX (optical ber) connections IRIG-B Synchronization...

Open the catalog to page 2
PRO-N - 3

VERSIONS NVA100X-B (BASE) The protective system for a feeder and a transformer is largely dependent on the size and the importance of the transformer. In case of transformers the usual practise is to provide overcurrent delayed and instantaneous protection for overloads, external short-circuit, terminal faults, winding faults. NVA100X-B is suitable for all these application and, moreover, also for protecting feeders and transformers from earth fault in case grounding through impedance, solidly earthed or isolated. Phase-to-phase faults, interturn faults, core faults are the other typical...

Open the catalog to page 3
PRO-N - 4

COMMUNICATION The evolution of the supervision and control systems in the electrical systems requires the possibility of setting up the protection relays as intelligent devices (IFD – Intelligent Field Devices) within communication networks consisting of general purpose devices such as PLCs or Personal Computers. To meet this need, THYTRONIC has geared its development strategy towards the search for “open” solutions: the Extended family provides communication protocols based on Ethernet technology such as MODBUS TCP/IP and IEC61850. These protocols allow the use of a single eld bus with all...

Open the catalog to page 4
PRO-N - 5

PROTECTION AND CONTROL ELEMENTS The protection elements are grouped according to typical applications as shown in the table below, but more combinations are easily achievable thanks to the configurable Hw-Sw structure of the PROMM Extended family Some versions (NVA100X-P) can be supplied with CT and VT or sensors (ThySensor) input circuits.

Open the catalog to page 5
PRO-N - 7

Earth faults Breaker failure Nota *: quando impiegata 87NHIZ, non sono impiegabili le funzioni 50N/51N/67N con corrente residua (IE) misurata direttamente - Protection & control elements 26 PtIOO thermal probes 46LT Negative sequence overcurrent 12/11 Negative/positive sequence current ratio 50N/51N/87NHIZ* Residual overcurrent/Restricted earth fault 50N(Comp)/51N(Comp) Calculated residual overcurrent 67 Phase directional overcurrent 67N Ground directional overcurrent 74TCS Trip circuit supervision Modbus TCP/IP

Open the catalog to page 7
PRO-N - 8

Overloads Short-circuits Earth faults Breaker failure Anti-islanding Load shedding - Independent power producers - Protection & control elements Nota *: quando impiegata 87NHIZ, non sono impiegabili le funzioni 50N/51N/67N con corrente residua (IE) misurata direttamente Overux (V/Hz) Synchrocheck Pt100 thermal probes Undervoltage Positive sequence undervoltage Undercurrent Negative sequence overcurrent Negative/positive sequence current ratio Phase reversa Thermal image Phase overcurrent Residual overcurrent/Restricted earth fault Calculated residual overcurrent Overvoltage Residual...

Open the catalog to page 8
PRO-N - 9

Overloads Short-circuits Earth faults Breaker failure Load shedding - Independent power producers Power based elements - Power factor - Protection & control elements Ingressi da TA-TV induttivi Nota *: quando impiegata 87NHIZ, non sono impiegabili le funzioni 50N/51N/67N con corrente residua (IE) misurata direttamente COMMUNICATION - Modbus RS485 - Modbus TCP/IP - IEC61850 - IEC 870-5-103/DNP3 Overux (V/Hz) Synchrocheck Pt100 thermal probes Undervoltage Positive sequence undervoltage Directional active overpower Directional reactive overpower Undercurrent Directional active underpower...

Open the catalog to page 9
PRO-N - 10

Overloads Short-circuits Earth faults Breaker failure Anti-islanding Load shedding - Independent power producers Power based elements - Power factor Stator faults Restart inhibition Windings heating Stalemate Voltage unbalance - Protection & control elements Nota *: quando impiegata 87NHIZ, non sono impiegabili le funzioni 50N/51N/67N con corrente residua (IE) misurata direttamente COMMUNICATION - Modbus RS485 - Modbus TCP/IP - IEC61850 - IEC 870-5-103/DNP3 Overux (V/Hz) Synchrocheck Pt100 thermal probes Undervoltage Positive sequence undervoltage Directional active overpower Directional...

Open the catalog to page 10
PRO-N - 11

NVA100X-C (CAPACITOR BANK/HARMONIC FILTER) • • • • • • Overloads Short circuits Phase unbalance Neutral unbalance with compensation Thermal image (for serie reactor protection) RMS currents (fundamental and harmonics) NVA100X-C - Protection & control elements Pt100 thermal probes Undervoltage Undercurrent Negative sequence overcurrent Thermal image Phase overcurrent RMS overcurrent Residual overcurrent/Restricted earth Calculated residual overcurrent Overvoltage Circuit breaker failure CT supervision Discharge timer Trip circuit supervision COMMUNICATION - Modbus RS485 - Modbus TCP/IP -...

Open the catalog to page 11
PRO-N - 12

THE COMPREHENSIVE SOLUTION FOR GENERATOR / MOTOR & TRANSFORMER PROTECTION WITH DIFFERENTIAL ELEMENTS NVA100X-D - Protective & control elements SYNCHRONIZING - SNTP - IRIG-B Note *: when 87NHIZ is enabled, the 50N/51N/67N functions can not be used with residual current (IE) measured directly 21 Underimpedance 24 Overux (U/f) 26 Thermal with Pt100 probes 27 Undervoltage 27V1 Positive sequence undervoltage 32P Directional active overpower 37 Undercurrent 37P Directional active underpower 40 Loss of eld 46M-46G Negative sequence overcurrent 47 Phase reversal 49MG Thermal image 50/51 Phase...

Open the catalog to page 12
PRO-N - 13

THE COMPREHENSIVE SOLUTION FOR TWO OR THREE WINDINGS TRANSFORMER PROTECTION NVA100X-T - Protection & control elements SIDE H or SIDE L or SIDE T 59N SIDE H or SIDE L or SIDE T 87NHIZ.2 SIDE H or SIDE L or SIDE T I E-1 24 sideL, H, T Overux 26 Pt100 27 sideL, H, T Undervoltage 37 sideL, H, T Undercurrent 46 sideL, H, T Negative sequence overcurrent I2/I1 sideL, H, T Negative/positive sequence current ratio 49 lati sideL, H, T Thermal image 50/51lati sideL, H, T Phase overcurrent 50N/51N/87NHIZ1[2]-21[3] Residual overcurrent/ High impedance restricted earth fault 59 lato sideL, H, T Phase...

Open the catalog to page 13