NA10

NA10

NA10

Product catalog summary
Overview: The NA10 Feeder Protection Relay is designed for radial networks to protect feeders and power transformers. It is compatible with solidly grounded systems and can be used in ungrounded or resistance grounded systems with limitations. It complies with CEI 0-16 requirements.
Protective & Control Functions: The relay includes phase overcurrent, residual overcurrent, breaker failure, CT supervision, and trip circuit supervision. It supports metering, oscillography, and event logging.
Communication: Multiple communication interfaces are available, including RS232, RS485 with Modbus RTU, IEC 60870-5-103, DNP3 protocols, and Ethernet with Modbus/TCP.
Man Machine Interface (MMI): Features a membrane keyboard, LCD display, and eight LEDs for status indication. Programming and settings adjustments can be made via MMI or PC software (ThySetter).
Construction & Design: Available in various mounting styles, it includes six output relays with programmable functions and supports modular design for extended I/O capabilities.
Control and Monitoring: Includes circuit breaker commands, diagnostic functions, cold load pickup, second harmonic restraint, and logic selectivity. User-defined logic can be customized according to IEC 61131-3 standards.
Self Diagnostics: Continuously checks hardware and software functions, reporting anomalies through display messages, LEDs, and output relays.
Specifications: Supports various mechanical, insulation, EMC, climatic, and safety standards. Operates within a wide range of environmental conditions and is CE certified.
Input & Output Circuits: Supports a range of auxiliary power supplies, phase and residual current inputs, binary inputs, and output relays with specific ratings and configurations.
General Settings: Allows detailed configuration of protective functions, including thermal protection, phase overcurrent, and residual overcurrent with various threshold and timing settings.
Specifications: Key parameters include operating times, activation times, reset time delays, and current thresholds for different protection elements.
Procedures: Details procedures for setting up and monitoring circuit breakers, including supervision of trips and CT supervision.
Standards and Norms: Adheres to standards for event recording, fault recording, and settings recording, using COMTRADE format for digital fault recording.
Recommendations: Suggests maintaining specific time delays and thresholds for optimal performance and provides guidelines for metering and recording electrical parameters.
Data and Analysis: Includes data on measured parameters such as frequency, phase currents, and harmonic currents, with insights into event and fault recording.
Diagrams and Illustrations: Contains connection diagrams and mounting instructions for installation and setup.
See more

Catalog excerpts

NA10-1

NA10 FEEDER PROTECTION RELAY THE BASIC SOLUTION FOR FEEDERS AND TRANSFORMERS PROTECTION The relay type NA10 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent protection can be used on feeders of any length, while in ungrounded or Petersen coil and/or resistance grounded systems, the residual overcurrent protection can be used on feeders of small length in order to avoid unwanted trippings due to the capacitive current contribution of the feeder on external ground fault. The relay complies with CEI 0-16 requirements. - Protective & control functions 50N/51N Control functions METERING - I L1..I L3,I E - Oscillography - Events & Faults log COMMUNICATION - RS232 - Modbus RS485 - Modbus TCP/IP - IEC 870-5-103/DNP3 Phase overcurrent Residual overcurrent Breaker failure CT supervision Trip circuit supervision

 Open the catalog to page 1
NA10-2

— Measuring inputs Three phase current inputs and one residual current input, with nominal currents independently selectable at 1 A or 5 A through — Binary inputs Two orfive binary inputs are available with programmable active state (active-ON/active-OFF) and programmable timer (active to OFF/ON or ON/OFF transitions). Several presettable functions can be associated to each input. According to the hardware configurations, the NA10 protection relay can be shipped in various case styles depending on the required mounting options (flush, projecting mounting, rack or with separate operator panel)....

 Open the catalog to page 2
NA10-3

— Self diagnostics — Control and monitoring Several predened functions are implemented: • Circuit Breaker commands and diagnostic. • Activation of two set point proles. • Phase CTs monitoring (74CT). • Logic selectivity. • Cold load pickup (CLP) with block or setting change. • Trip circuit supervision (74TCS). • Second harmonic restraint (inrush). • Remote tripping. User dened logic may be customized according to IEC 61131-3 standard protocol (PLC). Circuit Breaker commands and diagnostic Several diagnostic, monitoring and control functions are provided: • Health thresholds can be set; when the...

 Open the catalog to page 3
NA10-4

SPECIF ICAT IONS INPUT CIRCUITS — Auxiliary power supply Uaux — Mechanical data Mounting: ush, projecting, rack or separated operator panel Mass (ush mounting case) 2.0 kg — Insulation tests Reference standards High voltage test 50Hz Impulse voltage withstand (1.2/50 μs) Insulation resistance — Voltage dip and interruption Reference standards — EMC tests for interference immunity 1 MHz damped oscillatory wave Electrostatic discharge Fast transient burst (5/50 ns) Conducted radio-frequency elds Radiated radio-frequency elds High energy pulse Magnetic eld 50 Hz Damped oscillatory wave Ring wave...

 Open the catalog to page 4
NA10-5

— Relay output timers Minimum pulse width (t TR) PROTECTIVE FUNCTIONS — Thermal protection with RTD thermometric probes - 26 Alarm • Alarm threshold θALx (x=1...8) • Operating time t θALx (x=1...8) Trip • Trip threshold θ>x (x=1...8) • Operating time t θ >x (x=1...8) Note: The element becomes available when the MPT module is enabled and connected to Thybus — Phase overcurrent - 50/51 I> Element • I> Curve type (I>Curve) DEFINITE IEC/BS A, B, C, ANSI/IEEE MI, VI, EI RECTIFIER, I2t or EM • ICLP > Activation time (t CLP>) 0.00...100.0 s • I> Reset time delay (t > RES) 0.00...100.0 s Denite time...

 Open the catalog to page 5
NA10-6

Recording mode • Start/Trip of enabled protection or control element • Binary inputs switching (OFF/ON or ON/OFF) • Setting changes • Auxiliary supply Power UP/Power DOWN Data recorded: • Counter (resettable by ThySetter) 0...109 • Cause binary input/trip/setting change/Power ON/OFF •Time stamp Date and time Recording mode circular • Output relays of enabled protection or control element (OFF-ON) — Digital Fault Recorder (Oscillography) • External trigger (binary inputs) Data recorded: • Counter (resettable by ThySetter) • Time stamp • Fundamental RMS phase currents • Fundamental RMS residual...

 Open the catalog to page 6
NA10-7

— Connection diagram example MODULO 4 RELE’ + 8 INGRESSI DIGITALI 4 RELAYS + 8 BINARY INPUTS MODULE Supervision unit BINARY INPUTS CURRENT INPUTS

 Open the catalog to page 7
NA10-8

DIMENSIONS FRONT VIEW START TRIP FLUSH MOUNTING PROJECTING MOUNTING FLUSH MOUNTING PROJECTING MOUNTING (Separate operator panel) FLUSH MOUNTING PROJECTING MOUNTING (Separate operator panel) SEPARATE OPERATOR PANEL RACK MOUNTING PROJECTING MOUNTING (Stand alone) FLUSH MOUNTING CUTOUT START TRIP

 Open the catalog to page 8