NA016

NA016

NA016

Product catalog summary
Application
The NA016 relay is designed for protection in radial networks, particularly for feeders and power transformers. It is compatible with solidly grounded systems and can be adapted for ungrounded or resistance grounded systems with short feeders to avoid unnecessary tripping.

Specifications
The relay is compatible with both traditional and low power current transformers (CTs), adhering to CEI 0-16 standards. It offers phase and residual overcurrent protection, trip circuit supervision, and metering capabilities.

Protective & Control Functions
Key functions include phase overcurrent (50/51), residual overcurrent (50N/51N), and trip circuit supervision (74TCS).

Communication
Equipped with RS232 and RS485 interfaces, supporting Modbus RTU and IEC 60870-5-103 protocols for communication.

Self Diagnostics
The relay continuously monitors its hardware and software, reporting any anomalies through display messages, LEDs, and output relays.

Firmware Updating
Allows on-site firmware updates via flash memory units.

Programming and Settings
Configuration can be done through MMI or PC using ThyVisor software, with data stored in non-volatile memory, including event and fault records.

Measuring Inputs
Supports three-phase current inputs and one residual current input, with options for selecting nominal currents.

Output Relays
Includes four programmable output relays with customizable functions and reset modes.

Binary Inputs
Features three predefined binary inputs for capturing circuit breaker positions and supervising trip circuits.

Construction
Designed for flush or rack mounting, featuring a membrane keyboard, LCD display, and LEDs for user interaction.

Metering
Provides metering values for phase and residual currents using a DFT algorithm for RMS value measurement.

General Specifications
Covers mechanical data, insulation tests, EMC tests, climatic and mechanical tests, safety requirements, and environmental conditions.

Communication Interfaces
Includes local PC RS232 and RS485 ports with ModBus RTU/IEC 60870-5-103 protocol support.

Input Circuits
Details auxiliary power supply, phase current inputs, low power CTs, residual current input, and binary inputs.

Output Circuits
Describes output relays and LEDs.

General Settings
Includes rated values and relay output timers.

Protective Functions
Details phase and residual overcurrent elements, including operating times and reset delays.

Metering & Recording
Includes measured parameters, circuit breaker status, counters, event recorder, fault recorder, settings recorder, and digital fault recorder.
See more

Catalog excerpts

NA016-1

NA016 FEEDER PROTECTION RELAY THE ECONOMICAL SOLUTION FOR THE PROTECTION OF LINES AND TRANSFORMERS — Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent protection can be used on feeders of any length, while in ungrounded or Petersen coil and/or resistance grounded systems, the residual overcurrent protection can be used on feeders of small length in order to avoid unwanted trippings due to the capacitive current contribution of the feeder on external ground fault. The NA016 protection relay may be shipped with traditional CTs or low power (LPCT) current inputs. The relay complies with CEI 0-16 requirements. METERING - /L1../L3,/E - Oscillography - Events & Faults log - Data Logger - Protective & control functions 50/51 Phase overcurrent 50N/51N Residual overcurrent 74TCS Trip Circuit Supervision

 Open the catalog to page 1
NA016-2

— Measuring inputs Three phase current inputs and one residual current input, with nominal currents independently selectable at 1 A or 5 A (traditional CTs) or three phase currents for low-power CT (LPCT) with selectable rated current. — Output relays Four output relays are available (two changeover contacts); each relay may be individually programmed as normal state (normally energized or de-energized) and reset mode (manual or automatic). A programmable timer is provided for each relay (minimum pulse width). The user may program the function of each relay in accordance with a matrix (tripping...

 Open the catalog to page 2
NA016-3

GENERAL — Mechanical data Mounting: Mass (flush mounting case) — Insulation tests Reference standards High voltage test 50Hz Impulse voltage withstand (1.2/50 ms) Insulation resistance — Voltage dip and interruption Reference standards — EMC tests for interference immunity SPECIFICATIONS INPUT CIRCUITS Auxiliary power supply Uaux Nominal value (range) Operative range Power consumption (max) 1 MHz damped oscillatory wave Electrostatic discharge Fast transient burst (5/50 ns) Conducted radio-frequency fields Radiated radio-frequency fields High energy pulse Magnetic field 50 Hz Damped oscillatory...

 Open the catalog to page 3
NA016-4

0...109 description and parameter Date and time GENERAL SETTINGS Rated values Phase CT nominal primary current (/np) 1 A...1000 A Residual CT nominal primary current (/Enp) 1 A...1000 A Reading Direct / Relative Relay output timers Minimum pulse width (f tr) 0.01...0.50 s PROTECTIVE FUNCTIONS Phase overcurrent - 50/51 /> Element •/> Curve type (/>Curve) IEC/BS A, B, C • 50/51 First threshold inverse time (/>inv) 0.100...2.50 /n • / >inv Operating time (f>inv) 0.02...60.0 s />> Element • 50/51 Second threshold definite time (/ >>def) 0.100...20.0 /n • / >>def Operating time (f>>def) 0.03...10.00...

 Open the catalog to page 4
NA016-5

— Example of connection diagram with traditional CT inputs and acquisition of CB states for Data Logger +UAUX CB diagnostic (active only with Logger option) Trip Circuit supervision (TCS) UAUX UAUX (active only with Logger option) FRONT PANEL OUTPUT RELAYS

 Open the catalog to page 5
NA016-6

— Example of connection diagram with low power CT inputs and acquisition of CB states for Data Logger +UAUX LPCT Setting LPCTs CURRENT INPUTS OUTPUT RELAYS CB diagnostic (active only with Logger option) Trip Circuit supervision (TCS) UAUX UAUX (active only with Logger option) FRONT PANEL

 Open the catalog to page 6
NA016-7

FRONT VIEW SIDE VIEW DIMENSIONS REAR VIEW FLUSH MOUNTING CUTOUT IDENTIFICATION LABEL Traditional CT inputs - Logger H THYTRONIC Traditional CT inputs - no Logger H THYTRONIC ln Rated 50...500A/Extended 50...1250A /e„ 1A □ 5A □ A rr Uaux [24-230 Vac/dc | /!\C € 1 50-51 Low power CT inputs - Logger Low power CT inputs - no Logger ON: powered device and diagnostics OK START: start TRIP: trip Note: the 3,4 and 5 LEDs are active only with Logger option Keys (CB open) and (CB close) are disabled

 Open the catalog to page 7
NA016-8

THYTRONIC A PERSONALISED SERVICE OF THE PRODUCTION, A RAPID DELIVERY, A COMPETITIVE PRICE AND AN ATTENTIVE EVALUATION OF OUR CUSTOMERS NEEDS, HAVE ALL CONTRIBUTED IN MAKING US ONE OF THE BEST AND MOST RELIABLE PRODUCERS OF PROTECTIVE RELAYS. FORTY YEARS OF EXPERIENCE HAS MADE STANDARD THESE ADVANTAGES THAT ARE GREATLY APPRECIATED BY LARGE COMPANIES THAT DEAL ON THE INTERNATIONAL MARKET. A HIGHLY QUALIFIED AND MOTIVATED STAFF PERMITS US TO OFFER AN AVANT-GARDE PRODUCT AND SERVICE WHICH MEET ALL SAFETY AND CONTINUITY DEMANDS, VITAL IN THE GENERATION OF ELECTRIC POWER. OUR COMPANY PHILOSOPHY HAS...

 Open the catalog to page 8

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.