NA016
1 / 8Pages

Catalog excerpts

NA016 - 1

NA016 FEEDER PROTECTION RELAY THE ECONOMICAL SOLUTION FOR THE PROTECTION OF LINES AND TRANSFORMERS — Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent protection can be used on feeders of any length, while in ungrounded or Petersen coil and/or resistance grounded systems, the residual overcurrent protection can be used on feeders of small length in order to avoid unwanted trippings due to the capacitive current contribution of the feeder on external ground fault. The NA016 protection relay may be shipped with traditional CTs or low power (LPCT) current inputs. The relay complies with CEI 0-16 requirements. METERING - /L1../L3,/E - Oscillography - Events & Faults log - Data Logger - Protective & control functions 50/51 Phase overcurrent 50N/51N Residual overcurrent 74TCS Trip Circuit Supervision

Open the catalog to page 1
NA016 - 2

— Measuring inputs Three phase current inputs and one residual current input, with nominal currents independently selectable at 1 A or 5 A (traditional CTs) or three phase currents for low-power CT (LPCT) with selectable rated current. — Output relays Four output relays are available (two changeover contacts); each relay may be individually programmed as normal state (normally energized or de-energized) and reset mode (manual or automatic). A programmable timer is provided for each relay (minimum pulse width). The user may program the function of each relay in accordance with a matrix...

Open the catalog to page 2
NA016 - 3

GENERAL — Mechanical data Mounting: Mass (flush mounting case) — Insulation tests Reference standards High voltage test 50Hz Impulse voltage withstand (1.2/50 ms) Insulation resistance — Voltage dip and interruption Reference standards — EMC tests for interference immunity SPECIFICATIONS INPUT CIRCUITS Auxiliary power supply Uaux Nominal value (range) Operative range Power consumption (max) 1 MHz damped oscillatory wave Electrostatic discharge Fast transient burst (5/50 ns) Conducted radio-frequency fields Radiated radio-frequency fields High energy pulse Magnetic field 50 Hz Damped...

Open the catalog to page 3
NA016 - 4

0...109 description and parameter Date and time GENERAL SETTINGS Rated values Phase CT nominal primary current (/np) 1 A...1000 A Residual CT nominal primary current (/Enp) 1 A...1000 A Reading Direct / Relative Relay output timers Minimum pulse width (f tr) 0.01...0.50 s PROTECTIVE FUNCTIONS Phase overcurrent - 50/51 /> Element •/> Curve type (/>Curve) IEC/BS A, B, C • 50/51 First threshold inverse time (/>inv) 0.100...2.50 /n • / >inv Operating time (f>inv) 0.02...60.0 s />> Element • 50/51 Second threshold definite time (/ >>def) 0.100...20.0 /n • / >>def Operating time (f>>def)...

Open the catalog to page 4
NA016 - 5

— Example of connection diagram with traditional CT inputs and acquisition of CB states for Data Logger +UAUX CB diagnostic (active only with Logger option) Trip Circuit supervision (TCS) UAUX UAUX (active only with Logger option) FRONT PANEL OUTPUT RELAYS

Open the catalog to page 5
NA016 - 6

— Example of connection diagram with low power CT inputs and acquisition of CB states for Data Logger +UAUX LPCT Setting LPCTs CURRENT INPUTS OUTPUT RELAYS CB diagnostic (active only with Logger option) Trip Circuit supervision (TCS) UAUX UAUX (active only with Logger option) FRONT PANEL

Open the catalog to page 6
NA016 - 7

FRONT VIEW SIDE VIEW DIMENSIONS REAR VIEW FLUSH MOUNTING CUTOUT IDENTIFICATION LABEL Traditional CT inputs - Logger H THYTRONIC Traditional CT inputs - no Logger H THYTRONIC ln Rated 50...500A/Extended 50...1250A /e„ 1A □ 5A □ A rr Uaux [24-230 Vac/dc | /!\C € 1 50-51 Low power CT inputs - Logger Low power CT inputs - no Logger ON: powered device and diagnostics OK START: start TRIP: trip Note: the 3,4 and 5 LEDs are active only with Logger option Keys (CB open) and (CB close) are disabled

Open the catalog to page 7
NA016 - 8

THYTRONIC A PERSONALISED SERVICE OF THE PRODUCTION, A RAPID DELIVERY, A COMPETITIVE PRICE AND AN ATTENTIVE EVALUATION OF OUR CUSTOMERS NEEDS, HAVE ALL CONTRIBUTED IN MAKING US ONE OF THE BEST AND MOST RELIABLE PRODUCERS OF PROTECTIVE RELAYS. FORTY YEARS OF EXPERIENCE HAS MADE STANDARD THESE ADVANTAGES THAT ARE GREATLY APPRECIATED BY LARGE COMPANIES THAT DEAL ON THE INTERNATIONAL MARKET. A HIGHLY QUALIFIED AND MOTIVATED STAFF PERMITS US TO OFFER AN AVANT-GARDE PRODUCT AND SERVICE WHICH MEET ALL SAFETY AND CONTINUITY DEMANDS, VITAL IN THE GENERATION OF ELECTRIC POWER. OUR COMPANY PHILOSOPHY...

Open the catalog to page 8