NA011-Flyer

NA011-Flyer

NA011-Flyer

Product catalog summary
Overview: The NA011 feeder protection relay is designed for cost-effective protection of lines and transformers, featuring automatic reclosing capabilities. It is suitable for radial networks and can be used in both solidly grounded and ungrounded systems, with specific considerations for each type.
Protective and Control Functions: The relay includes phase overcurrent (50/51), residual overcurrent (50N/51N), automatic recloser (79), and breaker failure (BF) functions. It supports both traditional and low power current transformers (CTs and LPCTs) for current inputs, and provides metering capabilities for phase and residual currents.
Programming and Settings: Relay settings can be configured via a Man Machine Interface (MMI) or a PC using ThySetter software. It includes a cold load pickup (CLP) feature to prevent unwanted tripping during temporary overcurrents.
Communication: The NA011 relay features RS232 and RS485 communication interfaces, supporting Modbus RTU and IEC 60870-5-103 protocols for remote monitoring and control.
Self Diagnostics: The relay continuously monitors its hardware and software functions, reporting anomalies through display messages, communication interfaces, LEDs, and output relays.
Data Storage and Recording: The relay includes a sequence of event recorder, fault recorder, and digital fault recorder (oscillography), with data stored in non-volatile memory in COMTRADE format.
Specifications: Designed for flush or rack mounting, the relay weighs 1.2 kg and meets various insulation, EMC, climatic, and mechanical test standards, ensuring robust performance under different environmental conditions.
Input and Output Circuits: The relay supports a wide range of auxiliary power supply voltages and includes multiple binary inputs and output relays, each programmable for specific functions.
Protective Functions: The relay offers multiple threshold settings for phase and residual overcurrent protection, with both definite and inverse time characteristics. It also supports autoreclose functions with configurable reclosure cycles and times.
Construction and User Interface: The relay features a membrane keyboard, backlight LCD display, and multiple LEDs for status indication. It provides manual control of circuit breaker commands through dedicated keys.
See more

Catalog excerpts

NA011-Flyer-1

Protection Relays NA011 FEEDER PROTECTION RELAY THE ECONOMICAL SOLUTION FOR THE PROTECTION OF LINES AND TRANSFORMERS WITH AUTOMATIC RECLOSER — Application The relay type NA011 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent protection can be used on feeders of any length, while in ungrounded or Petersen coil and/or resistance grounded systems, the residual overcurrent protection can be used on feeders of small length in order to avoid unwanted trippings due to the capacitive current contribution of the feeder on external ground fault. The NA011 protection relay may be shipped with traditional CTs or low power (LPCT) current inputs; for both versions, the residual overcurrent protection can use the measured (CTs or balanced transformer) or the calculated residual current. 52 79 Phase CTs BF Control functions 50 Low power CTs (LPCT) 50 50N 51 METERING - I L1..I L3,I E Alternative - Oscillography - Events & Faults log - Data Logger 51 51N COMMUNICATION - RS232 - Modbus RS485 NA011 - Flyer - 05 - 2012 - Protective & control functions 50/51 50N/51N 79 BF Phase overcurrent Residual overcurrent Automatic recloser Breaker failure

 Open the catalog to page 1
NA011-Flyer-2

— Phase current inputs — Programming and settings Traditional CTs Three phase current inputs with secondary nominal currents independently selectable at 1 A or 5 A through DIP-switches. Low power CTs Three phase current inputs with primary nominal currents independently selectable through DIP-switches and software. — Residual current input Measured residual current One residual current input with secondary nominal current selectable at 1 A or 5 A through DIP-switches. Calculated residual current Residual current is calculated by the vector sum of the three phase currents, measured by three 1A...

 Open the catalog to page 2
NA011-Flyer-3

— Mechanical data Mass (flush mounting case) — Insulation tests Reference standards High voltage test 50Hz Impulse voltage withstand (1.2/50 u.s) Insulation resistance Reference standards — EMC tests for interference immunity INPUT CIRCUITS flush, rack 1 MHz damped oscillatory wave Electrostatic discharge Fast transient burst (5/50 ns) Conducted radio-frequency fields Radiated radio-frequency fields High energy pulse Damped oscillatory wave Ring wave Conducted common mode (0...150 kHz) Reference standards Climatic tests Reference standards Mechanical tests Reference standards Safety requirements...

 Open the catalog to page 3
NA011-Flyer-4

— Digital inputs PROTECTIVE FUNCTIONS — Phase overcurrent - 50/51 I> Element • I> Curve type (I>Curve) DEFINITE, IEC/BS A, B, C, ANSI/IEEE MI, VI, EI • ICLP > Activation time (t CLP >def ) 0.00...100.0 s • I> Reset time (t >RES) 0.00...100.0 s Denite time • 50/51 First threshold denite time (I> def ) 0.100...20.0 In • I> def within CLP (ICLP>def ) 0.100...20.0 In • I> def Operating time (t > def ) 0.03...10.00 s Inverse time • 50/51 First threshold inverse time (I>inv) 0.100...2.50 In • I>inv within CLP (ICLP>inv) 0.100...10.0 In • I>inv Operating time (t >inv) 0.02...60.0 s I>> Element • ICLP...

 Open the catalog to page 4
NA011-Flyer-7

FRONT VIEW REAR VIEW SIDE VIEW Traditional CT inputs Low power CT inputs FLUSH MOUNTING CUTOUT IDENTIFICATION LABEL Keys Q (CB open) antf|| <CB close>

 Open the catalog to page 7
NA011-Flyer-8

www.thytronic.it A PERSONALISED SERVICE OF THE PRODUCTION, A RAPID DELIVERY, A COMPETITIVE PRICE AND AN ATTENTIVE EVALUATION OF OUR CUSTOMERS NEEDS, HAVE ALL CONTRIBUTED IN MAKING US ONE OF THE BEST AND MOST RELIABLE PRODUCERS OF PROTECTIVE RELAYS. FORTY YEARS OF EXPERIENCE HAS MADE STANDARD THESE ADVANTAGES THAT ARE GREATLY APPRECIATED BY LARGE COMPANIES THAT DEAL ON THE INTERNATIONAL MARKET. A HIGHLY QUALIFIED AND MOTIVATED STAFF PERMITS US TO OFFER AN AVANT-GARDE PRODUCT AND SERVICE WHICH MEET ALL SAFETY AND CONTINUITY DEMANDS, VITAL IN THE GENERATION OF ELECTRIC POWER. OUR COMPANY PHILOSOPHY...

 Open the catalog to page 8