Overview
ThermoKey offers a wide range of dry coolers with capacities from 6kW to 2219 kW, tailored using the Archimede software based on parameters like fluid type, altitude, humidity, and air temperature. These solutions are designed for diverse sectors including data centers, hospitals, universities, stadiums, industrial plants, and energy facilities.
Specifications
Dry coolers are available in various configurations with single and dual fan rows, fan diameters from 500mm to 1000mm, and up to 20 fans with 8 sound levels. They are constructed using high-efficiency geometry and modular designs, with materials like copper or stainless steel piping and various fin materials.
Adiabatic Cooling Systems
ThermoKey offers systems like the Air Fresh System (AFS), Wet Fin System (WFS), and Evaporative Panel System (EPS) to enhance cooling efficiency by increasing air humidity and reducing temperature through evaporation.
Energy and Economic Analysis
The Archimede software allows for economic and energy analyses, assessing payback times and energy consumption. The dry coolers are Eurovent certified for performance reliability.
Optional Features
Options include stainless steel construction for aggressive environments, self-emptying systems to prevent freezing, and internal cleaning systems for V-type units. Accessories like speed controllers and custom electrical panels are also available.
Legionella Prevention
Systems are designed to prevent Legionella growth, complying with VDI 2047 Part 2 standards, using high-pressure nozzles to avoid standing water.
Environmental and Energy Efficiency
Dry coolers offer flexibility in energy management, with options to prioritize water or electricity consumption. They are available in energy classes up to A++, focusing on reducing noise and fan energy consumption.
Applications
  • Data Centers: Models with electronic fans and self-cleaning systems for precise temperature control, with a capacity requirement of 6.1 MW.
  • Hospitals: Systems meet hygienic standards and low noise requirements, with capacities from 1,520 kW to 13,056 kW.
  • Universities and Stadiums: Air conditioning solutions ensure comfort and efficiency.
  • Industrial and Energy Sectors: Used to control temperatures in production processes and power plants, with capacities up to 824 MW.
  • Food Processing: Systems ensure fluid temperature control with adiabatic systems, meeting hygienic standards.
Customer Support and Customization
ThermoKey provides personalized assistance for selecting heat exchanger solutions, with ongoing support throughout the product lifecycle, including spare parts and technical assistance.
Contact Information
ThermoKey Spa is located in Rivarotta di Rivignano Teor, Italy, and can be contacted via phone or email for further inquiries.
See more

Catalog excerpts

Dry Coolers-1

ThermoKey® Heat Exchange Solutions

 Open the catalog to page 1
Dry Coolers-2

Heat Exchange Solutions ThermoKey Every detail, even the smallest one, is designed to achieve the best Dry Cooler solution which meets the customer needs.

 Open the catalog to page 2
Dry Coolers-3

Heat Exchange Solutions Heat Exchange Solutions HKArchimede precision and reliability ThermoKey offers over 180,000 Dry Cooler solutions ■ More than 7,000 models. ■ 12 types of wiring. ■ More than 12 different types of fins and tubes material. ■ More than 40 fan types. ■ A wide range of fin spacing (from 1.6 mm to 4.5 mm). ■ Various fin thickness. Software Archimede selects the best Dry cooler solution (range from 6kW to 2219 kW) Entry working conditions (requested capacity, It is possible to verify the performances of each temperature and type of fluid, noise level and unit in one or more specific...

 Open the catalog to page 3
Dry Coolers-4

Heat Exchange Solutions Heat Exchange Solutions Every detail is designed to guarantee the best performances SELF-EMPTYING DRAINABLE SYSTEM ThermoKey has designed a proper self-emptying drainable system during winter time to avoid freezing risk of the finned pack. SPRAY J CLEANING SYSTEM On V-type units ThermoKey has designed a Cleaning System with internal nozzles which sprays water from the inside to the outside, in order to clean the heat exchanger. Reverse fan rotation LIFTING EYES ThermoKey has designed the lifting eyes to ensure a correct and easy handling of the dry cooler in compliance...

 Open the catalog to page 4
Dry Coolers-5

Heat Exchange Solutions Heat Exchange Solutions Dry Coolers range EUROVENT CERTIFICATION Eurovent certification confirms and guarantees that the performances of our Dry Coolers - Power Line table and V-Type - really correspond to the design conditions. POWER-J DRY COOLERS (1 FAN ROW) Performance range Capacity from 70 to 961 kW (ethylene glycol 35%, Tw1=40°C, Tw2=35°C, T1=25°C) Fans Diameter 0 800, 900, 1000 mm, AC or EC motor Benefits High efficiency geometry Modular design, 2-7 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range...

 Open the catalog to page 5
Dry Coolers-6

Heat Exchange Solutions Heat Exchange Solutions Adiabatic systems V-TOWER DRY COOLER Performance range Capacity from 290 to 2219 kW* Fans Diameter Ø 800, 900, 1000 mm, AC or EC motor Benefits EPS (Evaporative Panel System) Maximum performance, minimum footprint High efficiency geometry Modular design, 8-20 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range of materials Complete range of accessories TKMICRO H2O MODULAR LIQUID COOLER Performance range Capacity for each module up to 120 kW* Fans Diameter Ø 800 mm, AC or EC motor Modules...

 Open the catalog to page 6
Dry Coolers-7

Heat Exchange Solutions Heat Exchange Solutions Psichrometric diagram Operating modes of the adiabatic systems AFS DRY CONDITION with low ambient temperature, below the switch-point temperature, with fans at minimum. EVAPORTIVE PANEL SYSTEM ETH. GLYC. 35% ETH. GLYC. 35% ETH. GLYC. 35% Comparison chart DRY CONDITION with high ambient temperature, below the switch-point temperature, with fans at maximum. STANDARD AIR TEMPERATURE REDUCTION WATER CONSUMPTION WATER TREATMENT DIRECT ENERGY CONSUMPTION ENVIRONMENTAL INFLUENCE COIL PROTECTION FUNCTIONING HOURS MAINTENANCE COSTS LOW NECESSARY HIGH HIGH...

 Open the catalog to page 7
Dry Coolers-8

Heat Exchange Solutions Anti-Legionella and hygiene certificate Heat Exchange Solutions AFS Adiabatic System certification LEGIONELLA Legionella is a gram-negative bacillus, responsible for a severe infective disease called Legionnaires’ disease. Legionella survives in water and mud and it is transmitted by air. Moreover it has been ascertained its transmission by the air conditioning central system. The Legionnaires’ disease is a pulmonary infection caused by the Legionella pneumophila bacterium, which name means exactly “Legionella lover of the lungs”. The name Legionella was coined in 1976,...

 Open the catalog to page 8
Dry Coolers-9

Heat Exchange Solutions Heat Exchange Solutions * Characters always present in the code Flexibility in energy management One-coil dry cooler Double-coil dry cooler Super double-coil drycooler Double-coil dry cooler suitable for container loading • PRODUCT SERIES ThermoKey range of dry coolers gives the opportunity to select units with energy class up to A ++. With ThermoKey Adiabatic System (AFS) or even better with ThermoKey Hybrid System (WFS) the customer can choose whether to privilege the consumption of water or electricity or vice versa. Dry cooler with 32 and 42 geometry coils Dry cooler...

 Open the catalog to page 9
Dry Coolers-10

Heat Exchange Solutions HVAC used as external units in HVAC contribute to the optimization of air-conditioning systems in data centre, hospitals, hotels, theatres, etc. COOLING The Dry Coolers have been specifically designed to provide the best and most efficient solution. COOLING The Spital Thun hospital is part of a Switzerland hospital centre which provides medical assistance to 150,000 people among residents and tourists. Data centre NEED controlling precisely the temperature of data centre servers to improve their efficiency. CAPACITY REQUIRED total 6.1 MW. SOLUTION 18 Dry Coolers model...

 Open the catalog to page 10
Dry Coolers-11

Heat Exchange Solutions Applications COOLING through the ambient air and a closed circuit - without wasting water - dry coolers dissipate the heat generated and not usable by production processes, power plants, engines and moulds. lntemational group kacter inNEED guarantee the fluid temperature control at the requested maximum temperature thanks to the processing of food products. adiabatic system (EPS). Specific hygienic standards. CAPACITY REQUIRED total 16,565 kW. SOLUTION 5 pcs SJGH21090CN/04Q2EAF(EC)(EPS)S - 6 pcs SJGH2890C1/04Q2EAF(EC)(EPS) ENERGY & PROCESS COOLING Power plant Plastic Plant...

 Open the catalog to page 11
Dry Coolers-12

Heat Exchange Solutions We design customized products to meet every need We at ThermoKey know that specific environments require specific solutions, we are happy to help you to identify the best solution to your needs. Our technicians assist the customer in the choice Our technical staff is at your complete disposal to identify the best heat exchanger for you. We individually analyze your specific needs and the environment in which the heat exchanger will be installed for your needs. After sales ThermoKey stays at your side throughout the product life cycle for spare parts replacement and technical...

 Open the catalog to page 12

All THERMOKEY catalogs and technical brochures

  1. V-Tower

    9  Pages

  2. ACCESSORIES TK

    19  Pages

  3. Unit Coolers

    12  Pages

  4. Company profile

    17  Pages

  5. Oil Separators

    12  Pages

  6. product range

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.