ThermoKey® Heat Exchange Solutions
Open the catalog to page 1Heat Exchange Solutions ThermoKey Every detail, even the smallest one, is designed to achieve the best Dry Cooler solution which meets the customer needs.
Open the catalog to page 2Heat Exchange Solutions Heat Exchange Solutions HKArchimede precision and reliability ThermoKey offers over 180,000 Dry Cooler solutions ■ More than 7,000 models. ■ 12 types of wiring. ■ More than 12 different types of fins and tubes material. ■ More than 40 fan types. ■ A wide range of fin spacing (from 1.6 mm to 4.5 mm). ■ Various fin thickness. Software Archimede selects the best Dry cooler solution (range from 6kW to 2219 kW) Entry working conditions (requested capacity, It is possible to verify the performances of each temperature and type of fluid, noise level and unit in one or more specific...
Open the catalog to page 3Heat Exchange Solutions Heat Exchange Solutions Every detail is designed to guarantee the best performances SELF-EMPTYING DRAINABLE SYSTEM ThermoKey has designed a proper self-emptying drainable system during winter time to avoid freezing risk of the finned pack. SPRAY J CLEANING SYSTEM On V-type units ThermoKey has designed a Cleaning System with internal nozzles which sprays water from the inside to the outside, in order to clean the heat exchanger. Reverse fan rotation LIFTING EYES ThermoKey has designed the lifting eyes to ensure a correct and easy handling of the dry cooler in compliance...
Open the catalog to page 4Heat Exchange Solutions Heat Exchange Solutions Dry Coolers range EUROVENT CERTIFICATION Eurovent certification confirms and guarantees that the performances of our Dry Coolers - Power Line table and V-Type - really correspond to the design conditions. POWER-J DRY COOLERS (1 FAN ROW) Performance range Capacity from 70 to 961 kW (ethylene glycol 35%, Tw1=40°C, Tw2=35°C, T1=25°C) Fans Diameter 0 800, 900, 1000 mm, AC or EC motor Benefits High efficiency geometry Modular design, 2-7 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range...
Open the catalog to page 5Heat Exchange Solutions Heat Exchange Solutions Adiabatic systems V-TOWER DRY COOLER Performance range Capacity from 290 to 2219 kW* Fans Diameter Ø 800, 900, 1000 mm, AC or EC motor Benefits EPS (Evaporative Panel System) Maximum performance, minimum footprint High efficiency geometry Modular design, 8-20 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range of materials Complete range of accessories TKMICRO H2O MODULAR LIQUID COOLER Performance range Capacity for each module up to 120 kW* Fans Diameter Ø 800 mm, AC or EC motor Modules...
Open the catalog to page 6Heat Exchange Solutions Heat Exchange Solutions Psichrometric diagram Operating modes of the adiabatic systems AFS DRY CONDITION with low ambient temperature, below the switch-point temperature, with fans at minimum. EVAPORTIVE PANEL SYSTEM ETH. GLYC. 35% ETH. GLYC. 35% ETH. GLYC. 35% Comparison chart DRY CONDITION with high ambient temperature, below the switch-point temperature, with fans at maximum. STANDARD AIR TEMPERATURE REDUCTION WATER CONSUMPTION WATER TREATMENT DIRECT ENERGY CONSUMPTION ENVIRONMENTAL INFLUENCE COIL PROTECTION FUNCTIONING HOURS MAINTENANCE COSTS LOW NECESSARY HIGH HIGH...
Open the catalog to page 7Heat Exchange Solutions Anti-Legionella and hygiene certificate Heat Exchange Solutions AFS Adiabatic System certification LEGIONELLA Legionella is a gram-negative bacillus, responsible for a severe infective disease called Legionnaires’ disease. Legionella survives in water and mud and it is transmitted by air. Moreover it has been ascertained its transmission by the air conditioning central system. The Legionnaires’ disease is a pulmonary infection caused by the Legionella pneumophila bacterium, which name means exactly “Legionella lover of the lungs”. The name Legionella was coined in 1976,...
Open the catalog to page 8Heat Exchange Solutions Heat Exchange Solutions * Characters always present in the code Flexibility in energy management One-coil dry cooler Double-coil dry cooler Super double-coil drycooler Double-coil dry cooler suitable for container loading • PRODUCT SERIES ThermoKey range of dry coolers gives the opportunity to select units with energy class up to A ++. With ThermoKey Adiabatic System (AFS) or even better with ThermoKey Hybrid System (WFS) the customer can choose whether to privilege the consumption of water or electricity or vice versa. Dry cooler with 32 and 42 geometry coils Dry cooler...
Open the catalog to page 9Heat Exchange Solutions HVAC used as external units in HVAC contribute to the optimization of air-conditioning systems in data centre, hospitals, hotels, theatres, etc. COOLING The Dry Coolers have been specifically designed to provide the best and most efficient solution. COOLING The Spital Thun hospital is part of a Switzerland hospital centre which provides medical assistance to 150,000 people among residents and tourists. Data centre NEED controlling precisely the temperature of data centre servers to improve their efficiency. CAPACITY REQUIRED total 6.1 MW. SOLUTION 18 Dry Coolers model...
Open the catalog to page 10Heat Exchange Solutions Applications COOLING through the ambient air and a closed circuit - without wasting water - dry coolers dissipate the heat generated and not usable by production processes, power plants, engines and moulds. lntemational group kacter inNEED guarantee the fluid temperature control at the requested maximum temperature thanks to the processing of food products. adiabatic system (EPS). Specific hygienic standards. CAPACITY REQUIRED total 16,565 kW. SOLUTION 5 pcs SJGH21090CN/04Q2EAF(EC)(EPS)S - 6 pcs SJGH2890C1/04Q2EAF(EC)(EPS) ENERGY & PROCESS COOLING Power plant Plastic Plant...
Open the catalog to page 11Heat Exchange Solutions We design customized products to meet every need We at ThermoKey know that specific environments require specific solutions, we are happy to help you to identify the best solution to your needs. Our technicians assist the customer in the choice Our technical staff is at your complete disposal to identify the best heat exchanger for you. We individually analyze your specific needs and the environment in which the heat exchanger will be installed for your needs. After sales ThermoKey stays at your side throughout the product life cycle for spare parts replacement and technical...
Open the catalog to page 1213 Pages
9 Pages
19 Pages
12 Pages
17 Pages
20 Pages
12 Pages
44 Pages
12 Pages
12 Pages
8 Pages
44 Pages
12 Pages
12 Pages
24 Pages
16 Pages
8 Pages
12 Pages
23 Pages
10 Pages
23 Pages
7 Pages
22 Pages
20 Pages
16 Pages
16 Pages
12 Pages
12 Pages
1 Page