Group: Thermokey
Catalog excerpts
Data Centre Cooling Solutions
Open the catalog to page 1Heat Exchange Solutions DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that 1,5% of globally generated power is used for Data Centre cooling. GREEN SOLUTIONS AHRI and ASHRAE released standards to make Data Centres more efficient. ThermoKey is ready to take up this challenge.
Open the catalog to page 2Heat Exchange Solutions Heat Exchange Solutions Product features Heat removal methods in Data Centres Data Centres (also referred to as server rooms or IT rooms) and Data Centre Cooling have undergone significant developments since the first introduction of the ASHRAE recommendations and “Thermal Guidelines for Data Processing Environments” in 2004. Every element of IT equipment that consumes power produces an equivalent amount of heat in return. The ASHRAE recommendations, are the de-facto standard for thermal management in the Data Centre industry. Evolution of the guidelines aims to...
Open the catalog to page 3Heat Exchange Solutions ThermoKey Solutions Operational Reliability § Low Noise Emissions § Energy Cost Savings § High-Quality Components § Controlled Unit Operation § Customized Special Needs Remote condensers Example: Air cooled CRAC with integrated compressor. Heat removal from the server room using a remote condenser installed outside. Application of use: Medium and small wiring cabinets, computer rooms and Data Centre with moderate requirements (lower than 200KW). Air-cooled CRAC ThermoKey Condenser MICROCHANNEL CONDENSERS (MPE 25mm, 32mm) Area of use Gas condensation Performance range...
Open the catalog to page 4Heat Exchange Solutions Dry Coolers without chiller Glycol-cooled CRAC Water-cooled CRAC Dry Coolers with chiller CRAH Pumped refrigerant heat exchanger Heat Exchange Solutions Example: Glycol (or water) cooled CRAC with a pump. Heat removal from the server room using a drycooler installed outside. Instead of the drycooler, an adiabatic cooler can be used when the external ambient conditions or efficiency permit it. Application of use: In computer room and medium Data Centres (30-1000KW). Glycol Condenser water ThermoKey Dry Cooler ThermoKey Dry Cooler with Adiabatic System POWER-J DRY...
Open the catalog to page 5Heat Exchange Solutions Heat Exchange Solutions POWER-J (V-TOWER) DRY COOLER Performance range Capacity from 290 to 2219 kW* Adiabatic systems Fans Diameter Ø 800, 900, 1000 mm, AC or EC motor Modules From 1 to n Benefits EPS (Evaporative Panel System) Maximum performance, minimum footprint High efficiency geometry Modular design, 8-20 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range of materials Complete range of accessories AFS (Air Fresh System) or WFS (Wet Fin System) available upon request Evaporative Panel System The...
Open the catalog to page 6Heat Exchange Solutions Heat Exchange Solutions AFS AIR FRESH SYSTEM ThermoKey adiabatic cooling system equipped with special high-pressure nozzles, which allows to compensate for the peaks of power to be dissipated, with minimum water consumption for a maximum of 500 hours per year. The combination of high pressure water, the nebulization effect of nozzles (MISTING effect) and a specially designed electronic control system represent the innovative principle of AFS system. It uses only the quantity of water necessary to obtain the desired adiabatic effect. Tüv Certificated: “No danger in...
Open the catalog to page 7Heat Exchange Solutions Heat Exchange Solutions Considering a typical range of temperatures at a Data Centre in London and combining a 166KW Chiller and a 1000KW Power J. Dry Cooler (our model: JGQ2790B1 with wet fin system), it is possible to distinguish the free cooling mode and chiller mode throughout the year. Chiller consumptions in free cooling mode at standard London temperatures. 900 800 700 Energy consumption Energy consuption (Chiller with free cooling) Energy consuption (Chiller without free cooling) Year total consumption Temperatures distribution London Winter/Free Cooling...
Open the catalog to page 8Heat Exchange Solutions Heat Exchange Solutions ThermoKey “Archimede” tool ThermoKey offers various solutions for the electrical and regulation components.Here are some of our main components: Q2E - THREE-PHASE ELECTRICAL PANEL Electric box for EC fans with plastic casing. Electrical panel for EC fans with paint coated metal casing, controller mounted inside the box, protected by automatic switches (circuit breakers) connected to groups of fans, fan regulation control MODBUS RS485. Q3E - THREE-PHASE ELECTRICAL PANEL Electric box for EC fans with plastic casing and fan switches (1x2)....
Open the catalog to page 9Heat Exchange Solutions Heat Exchange Solutions Case studies Data Centre 6.1 MW The Dry Coolers have been specifically designed to provide the best and most efficient solution. NEED Cooling down one of the biggest Data Centres (6.1 MW) in a particularly aggressive environment like the coastal one. SOLUTION 16 V-Type Dry Coolers model JGH2390CZ2/6QIEMAF(EC)(AFS)S and 2 V-Type Dry Coolers model JWQ1290A3/8QIEMAF(EC)(AFS)S with electronic fans, adiabatic and self-cleaning system. Server in Basel (Switzerland) ThermoKey Dry Coolers have been produced to ensure durability and reduced energy...
Open the catalog to page 10Heat Exchange Solutions Heat Exchange Solutions We design customized products to meet every need We at ThermoKey know that specific contexts require specific solutions, we are happy to help you to identify the best solution to your needs. Our technicians assist the customer in the choice Data Centre 5.5 MW ThermoKey è stato scelto per la sostituzione di 3 dry cooler esistenti di un altro brand per il raffreddamento di un Data Center ad Amsterdam. Our technical staff is at your complete disposal to identify the best heat exchanger for you. We individually analyse your specific needs and the...
Open the catalog to page 11Heat Exchange Solutions Heat Exchange Solutions
Open the catalog to page 12ThermoKey Spa via dell’Industria, 1 - 33061 Rivarotta di Rivignano Teor (UD) - Italy T. +39 0432 772300 F. +39 0432 779734 info@thermokey.com www.thermokey.com
Open the catalog to page 13All THERMOKEY catalogs and technical brochures
-
V-Tower
9 Pages
-
Dry Coolers
13 Pages
-
ACCESSORIES TK
19 Pages
-
Unit Coolers
12 Pages
-
Company profile
17 Pages
-
Microchannel Condensers
20 Pages
-
Oil Separators
12 Pages
-
Power line Dry Coolers
44 Pages
-
Hermetic Condensers
12 Pages
-
Liquid Receivers
12 Pages
-
product range
8 Pages
-
power line and power J coolers
44 Pages
Archived catalogs
-
Contra Flows
1 Pages
-
Marine Condensers
12 Pages
-
Shell and Tubes Condensers
16 Pages
-
Evaporators TLE Serie
12 Pages
-
Evaporators TME Serie
16 Pages
-
Brazed Plates
20 Pages
-
Ammonia Unit Coolers
22 Pages
-
Finned Packs
7 Pages
-
Brine Unit Coolers
23 Pages
-
Industrial Unit Coolers
23 Pages
-
Radial Unit Coolers
10 Pages
-
Light Cubic Unit Coolers
12 Pages
-
Blast Freezer Unit Coolers
8 Pages
-
Turbo-J Condensers
12 Pages
-
Turbo-line Condensers
16 Pages
-
Power-J Dry coolers
12 Pages
-
Power-line Dry coolers
24 Pages