ICS-2100/1600/1100

ICS-2100/1600/1100

ICS-2100/1600/1100

Product catalog summary
Overview of ICS Series
The ICS-1100, ICS-1600, and ICS-2100 are high-performance ion chromatography systems designed for productivity and sensitivity. They feature dual piston pumps, conductivity detectors, and chromatography compartments. The ICS-2100 is notable for its Electrolytic Sample Preparation (ESP) capabilities, while the ICS-1100 and ICS-1600 focus on Eluent Regeneration (ER) for continuous operation.
ICS-1100 Series
Standard features include a dual piston pump, thermostated digital conductivity cell, electrolytic suppression, and Chromeleon® SE Control Software. Options include eluent regeneration, column heater, in-line vacuum degas, and sample preparation valve.
ICS-1600 Series
This series adds a touch pad front panel control and column heater to the features of the ICS-1100. It also supports eluent regeneration and in-line vacuum degas as options.
ICS-2100 Series
Features integrated eluent generation (EG) and electrolytic sample preparation (ESP). It supports a variety of automated sample preparation techniques and includes a touch pad front panel, dual piston pump, and column heater.
Key Features and Technologies
  • Eluent Generation and Regeneration: The ICS-2100 integrates eluent generation, eliminating manual preparation. The ICS-1100 and ICS-1600 focus on eluent regeneration for extended use.
  • Electrolytic Suppression: Supports all Dionex suppressor technologies, providing low noise and drift, reduced background conductivity, and fast start-up times.
  • Conductivity Detection: High-performance thermostated cell for stable operation and wide dynamic range.
  • Chromeleon Software: Offers powerful control and data processing, with features like eWorkflows, application templates, and a calibration wizard.
Performance and Reproducibility
The systems demonstrate excellent reproducibility and consistency across different labs and applications, with low retention time variability and high sensitivity for ion chromatography.
Applications and Use Cases
These systems are suitable for a wide range of ion chromatography applications, including anion and cation analysis, with compliance to U.S. EPA methods 300.0 and 300.1.
Introduction
This document discusses various techniques and solutions provided by Dionex Corporation for improving sample filtration and chromatography processes. It highlights the challenges and solutions related to sample contamination, matrix elimination, and sample preconcentration.
Sample Filtration
Off-line sample filtration is labor-intensive and costly, while in-line filtration can lead to contamination. Backflushing is presented as a solution to these issues, offering more accurate results.
On-Line Matrix Elimination
Organic materials can damage analytical columns. Trap columns can remove these materials, but their lifespan is limited. Automated column wash or backflush extends trap column life, prevents carryover, and eliminates contamination. Combining matrix elimination with on-line filtration offers further protection.
Sample Preconcentration
Concentrating large-volume samples allows for eluent regeneration to determine low analyte concentrations and improves chromatography by narrowing analyte bands. Optional valves facilitate automated preconcentration, and an electrolytic water purifier reduces analyte background.
System Components
The document describes components such as large and small loops, concentrators, analytical columns, guard columns, suppressors, and detectors. It also mentions the optional water polisher in RFIC-ESP systems, which aids in preconcentration or matrix elimination.
Customer Support and Services
Dionex offers comprehensive customer support, including after-sales service, on-site training, and system qualification services. They provide training for all levels of expertise and ensure systems are installed and maintained for optimal performance.
Commitment to Customer Satisfaction
Dionex emphasizes its dedication to problem-solving and customer satisfaction, offering system validation, custom service agreements, and complete instrument and application support.
See more

Catalog excerpts

ICS-2100/1600/1100-1

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:13.00pt "Arial", sans-serif; } -tonChromatograph ICS-1100ICS-1600 ICS-2100 Systems

 Open the catalog to page 1
ICS-2100/1600/1100-2

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.95pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:15.00pt "Arial", sans-serif; } .font4 { font:24.00pt "Microsoft Sans Serif", sans-serif; } CDedicDsteczl System ICS-1100 Sries ICS-1600 Sries Standard Features 驕 Dual Piston Pump Thermostated Digital ConductivityCell Օ Electrolytic Suppression LED Status Front Panel ՕChromeleon® SE Control Software Eluent regenerator control Options Օ Eluent Rgn驩ration (RFIC-ER) ٕ Column Heater In-LineVacuum Degas...

 Open the catalog to page 2
ICS-2100/1600/1100-3

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:5.25pt "Arial", sans-serif; } .font2 { font:5.95pt "Arial", sans-serif; } .font3 { font:6.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Arial", sans-serif; } .font5 { font:9.00pt "Arial", sans-serif; } .font6 { font:4.00pt "Impact", sans-serif; } C3cDn*Figi_j restions i Elue nt ICS-2100 Sries Standard Features Touch Pad Front Panel Control 镕RFIC-EG" System ♦ Eluent Gnration ♦ Electrolytic Gradients ♦ Electrolytic Suppression ♦CR-TCTrapColumn 驕 Dual Piston Pump Thermostatted Digital...

 Open the catalog to page 3
ICS-2100/1600/1100-4

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:16.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Times New Roman", serif; } Irrtegrefted Ion Chromot Dionex's high-performance integrated Reagent-Free ion chromatography (RFICٙ) Systems, the ICS-1100, ICS-1600, and ICS-2100, provide the ultimate in productivity for low cost per analysis while maintaining very high sensitivity results. They combine the power of on-line sample preparation with all...

 Open the catalog to page 4
ICS-2100/1600/1100-5

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:5.25pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:14.00pt "Arial", sans-serif; } ographs the ics-2100 system Front Panel The LCD touch-pad front panel on the ICS-1600 and ICS-2100 pro vides clear identification of key operating parameters, permitting "at instrument" control and monitoring. Eluent Generator & Eluent concentrations can be changed with the click of a mouse. Atmospheric carbonate contamination...

 Open the catalog to page 5
ICS-2100/1600/1100-7

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.25pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:9.00pt "Arial", sans-serif; } Automated Sample Prparation The sample prparation capabilities available with the ICS-1100, -1600, and -2100 Systems allow a wide variety of automated labor-saving techniques: Electrolytic Sample Pr驩paration The auxiliary power supply on the ICS-2100 allows control of electrolytic sample prparation devices,suchastheSelf-Regenerating®...

 Open the catalog to page 7
ICS-2100/1600/1100-8

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:14.00pt "Arial", sans-serif; } .font5 { font:16.00pt "Arial", sans-serif; } .font6 { font:7.00pt "Times New Roman", serif; } C3cDr"in|3lete CZLJsrtCDinner* Support Corporate Headquarters ComplϨte Solutions Dionex is committed to providing total customer support through after-sales service, on-site training, system qualification services, and a broad range...

 Open the catalog to page 8

All Thermo Fisher Scientific - Industrial & Applied S catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.