Overview: The Thermo Scientific Dionex ASE 150 and 350 systems are advanced automated tools for accelerated solvent extraction, designed to efficiently extract solid and semisolid samples with reduced solvent use.
Key Features:
  • Flexibility: Supports sample sizes from 1 to 100 g, ensuring consistent extraction results.
  • Efficiency: Reduces solvent consumption by 50–90% and performs extractions in 12–20 minutes.
  • Technology: Uses elevated temperature and pressure for enhanced extraction efficiency, with a chemically inert Dionium pathway for acid or base-treated samples.
System Specifications:
  • Dionex ASE 150: Features various collection bottle sizes, a faster pump, and a safety shield.
  • Dionex ASE 350: Offers flexibility with multiple vial and bottle options, solvent saver mode, and an integrated solvent controller.
Applications:
  • Environmental Analysis: Effective for extracting pesticides, PAHs, PCBs, and more, approved for EPA methods.
  • Food Analysis: Determines contaminants and nutritional content in food products.
  • Pharmaceuticals: Extracts natural products and verifies compound levels in supplements and pharmaceuticals.
  • Chemical and Polymer Industries: Characterizes polymer structures and extracts additives efficiently.
Benefits:
  • Time and Solvent Savings: Significant reduction in extraction time and solvent use.
  • Comprehensive Sample Preparation: Integrates pretreatment, extraction, and post-extraction cleanup.
Conclusion: The Dionex ASE 150 and 350 systems offer high capability, flexibility, and productivity for laboratories needing efficient and automated extraction solutions.
Additional Features: The systems support unattended extraction of up to 24 samples, with sample cell sizes ranging from 1 to 100 mL and collection vial sizes of 60 or 250 mL. They operate at a pressure of 1500 psi (100 bar) and include automatic system rinsing and solvent saver mode.
Specifications:
  • Power: 500 VA watts max, Voltage: 100–120 or 220–240 VAC, Frequency: 50/60 Hz.
  • Pneumatic: N2 at 1034–1340 kPa, Air at 400–827 kPa (ASE 350 optional).
  • Dionex ASE 150 Dimensions: 56.1 x 35.6 x 50.8 cm, Weight: 34 kg.
  • Dionex ASE 350 Dimensions: 69.3 x 67.3 x 61.7 cm, Weight: 65 kg.
Support and Services: Thermo Fisher Scientific provides training, installation, warranty service, and comprehensive support programs.
Contact Information: Global support and availability are emphasized with contact numbers for various countries.
See more

Catalog excerpts

ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-1

Thermo Scientific Dionex Automated Sample Preparation Accelerated Solvent Extraction

 Open the catalog to page 1
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-2

Advanced Extractions ASE 150 and ASE 350 Solvent Extractors Deliver Greater Capabilities Unsurpassed Extraction Technology The Thermo Scientific Dionex ASE Accelerated Solvent Extractor for solid samples and the Thermo Scientific Dionex AutoTrace Solid-Phase Extraction instrument for liquid samples provide your lab with total sample preparation. The Dionex ASE™ system uses a combination of elevated temperature and pressure with common solvents to increase the efficiency of the extraction process. The result is faster extraction times and a significant reduction in solvent use. The Dionex ASE...

 Open the catalog to page 2
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-3

High Capability, Flexibility, Productivity Dionex ASE 150 and 350 extractors deliver many advantages to laboratories requiring automated solid and semisolid extraction. The Dionex ASE 350 extractor handles 1–100 g of sample, combining the abilities of the previous Dionex ASE 200 and ASE 300 into a single system. It also includes an integrated solvent controller, reducing bench space requirements. Both the Dionex ASE 150 and 350 systems include a faster pump (70 mL/min), which means greater productivity for your laboratory. ASE Performs Extraction in Minutes Other extraction techniques can take...

 Open the catalog to page 3
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-4

Extraction Applications ASE Meets Your Application Requirements Environmental Analysis Food Analysis For environmental applications, ASE is proven to produce data equivalent to or better than traditional methods. ASE is accepted for use in EPA Method SW-846 3545 for the extraction of: • Pesticides and herbicides • PAHs and semivolatile compounds • PCBs • Dioxins and furans • TPH (DRO) • Explosive compounds ASE is also accepted for use in EPA Method SW-846 6860 for the determination of perchlorate and in CLP OLM 04.2 A for semivolatiles and pesticides. More recently, ASE has proven effective in...

 Open the catalog to page 4
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-5

Extraction for Marker Compounds from Natural Products Dianthrones (St. John’s Wort) Deacylsaponins (Horse Chestnut) Silybin (Milk Thistle) Curcumin (Tumeric Rhizome) Thymol (Thyme) Soxhlet & Reflux Steam Distillation Petrol MeOH Hexane MeOH Total Time Pharmaceuticals, Dietary Supplements Chemical, Petrochemical, Polymers For pharmaceuticals, natural products, and dietary supplements, ASE is used to: In the polymer industry, ASE is used to characterize polymer structures using ASTM method D-7210: • Extraction of plasticizers from PVC • Extraction of polypropylene and polyethylene for additives...

 Open the catalog to page 5
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-6

Sample Preparation ASE Goes Beyond Extraction to Deliver a Comprehensive Solution Sample preparation is a critical link in the overall analytical process. It often requires many steps and multiple hours to prepare samples for Chromatography. To improve productivity and minimize turnaround time, sample preparation requires more than just speed of the solvent extraction step. The ability to integrate pretreatment, solvent extraction, and post-extraction cleanup are critical for total productivity. Integration of these steps improves overall productivity, reduces sample handling, and minimizes preparation...

 Open the catalog to page 6
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-7

Choosing Dionex ASE Your Choice Is No Longer Based Solely On Sample Size Which ASE is right for you? Dionex ASE 350 Accelerated Solvent Extractor The two Dionex ASE systems are designed to meet the extraction requirements of the full spectrum of laboratories performing solid and semisolid solvent extraction. Each Dionex ASE system uses elevated temperature and pressure to greatly accelerate extractions. Dionex ASE systems feature: The Dionex ASE 350 is designed for high-throughput labs with large sample volume requirements. It is ideal for the busy environmental, biotech, pharmaceutical, chemical,...

 Open the catalog to page 7
ASE Series Automated Sample Preparation Accelerated Solvent Extractors Brochure-8

Our goal is to provide you with solutions to your extraction challenges rather than just selling you an instrument. You get a complete solution, and a partner committed to your success. To meet that goal, we offer a complete line of training, installation and warranty service, and comprehensive support programs. System Specifications Power Requirements Consumption: 500 VA watts max. Voltage: 100–120 or 220–240 VAC Frequency: 50/60 Hz Pneumatic Requirements: Dionex ASE 150 Dimensions (h x w x d): 56.1 x 35.6 x 50.8 cm (22.1 x 14.0 x 20.0 in.) Weight: 34 kg (75 lb) Dionex ASE 350 Dimensions (h...