SY-6 / CY-6 ThermalProtectors for Star Connection-1

rotectors (TP) of type Y6 with normally closed contacts are designed to protect small three-phase motors up to 700 VA (1.6A*440V) against overheating. The Y6-types can be placed between the windings of different phases because of their housing pressure stability and impregnation resistance. > The design of the Y6-types is based on the well proven mechanism of Thermik֒s product series 06 with three connection leads for a star point connection. Versions : SY6 - with insulation cap CY6 - without insulation cap > If - in the case of overheating - the rated switching temperature of the bimetal is reached, it suddenly snaps over and disconnects the two contacts and the contact- bridge. Now, each phase is disconnected from the other ones. Automatic reset immediately after a significant temperature drop. > Compact design with high pressure stability For star connection : to use without any relay Quick response sensitivity : featured by the metal housing and small protector mass Excellent long term performance : due to fine silver contacts. Reproducible switching temperature values due to tempered, mechanically and electrically unstressed bimetallic disc Very short bounce times : < 1 ms Instantaneous switching : with constant contact pressure over the whole temperature range. Minimal burning-off of the contacts Temperature resistance : by use of high temperature resistant materials and components > Thermik Gertebau GmbH ? P.O. Box 101980 ? D-75119 Pforzheim /Germany ? Phone: +49 (72 31) 60 040 ? Fax: +49 (72 31) 60 04-100 size="-1">

 Open the catalog to page 1
SY-6 / CY-6 ThermalProtectors for Star Connection-2

Contact type NC normally closed - Nominal switching temperature > ( NST) 70 ְC - 180 C > in steps of 5 K Standard tolerance б 5 K Resetting temperature (RST) Standard: CSA: UL: NST 70C - 180аC: > 35C NST 70аC - 180C: RST = NST Ж10K to NST 50K NST 70ְC - 180C: RST = Ж 50K 15K Operating voltage Up to 480 V DC ratings available, corresponding values on inquiry Rated voltage 3 x 440 V 50/60 Hz Rated current I > NOM 2.5 A @ cos (phi) = 1.0 10,000 switching cycles 1.6 A @ cos (phi) = 0.6 10,000 switching cycles Current sensitivity at I > NOM no Max. switching current at 250V~ 5.0 A 2,000 switching...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.