Overview: This document outlines the specifications and guidelines for thermal protectors and temperature sensors, detailing their types, applications, and technical parameters. It includes information on automatic resetting thermal protectors, PTC thermistor sensors, and KTY temperature sensors.
Thermal Protectors:
  • Types: Includes normally closed (automatic resetting) and normally closed with electrical self-hold functionality.
  • Specifications: Nominal switching temperatures range from 70°C to 180°C with standard tolerances. They can operate at voltages up to 500V AC/DC.
  • Performance: Rated currents vary by load type, with specific switching cycles for different configurations.
  • Physical Characteristics: Details on dimensions and connections, including diameter, height, and lead wire specifications.
  • Approvals: Compliance with standards such as IEC/EN 60730, VDE, UL, and CSA.
PTC Thermistor Sensors:
  • Insulation Materials: Options include Mylar-Nomex, Kynar, and Teflon.
  • Temperature Range: Nominal response temperatures from 70°C to 180°C.
  • Voltage Specifications: Operating voltage ranges from 2.5 VDC to 24 VDC, with a maximum of 30 VDC.
  • Physical Dimensions: Specifications for diameter and height, with details on insulation cap length.
KTY Temperature Sensors:
  • Functional Principle: These sensors are temperature-dependent, with resistance increasing as temperature rises, used in industrial and automotive applications.
  • Specifications: Nominal response temperatures range from -40°C to 250°C, with high voltage insulation up to 2.5 kV.
  • Applications: Suitable for motors, transformers, and heating systems due to their reliability and accuracy.
General Notes: Users are responsible for ensuring the suitability of Thermik products for specific applications, as deviations from standard guidelines are not inspected for usability or norm conformity.
See more

Catalog excerpts

Product tables-1

Thermal-Protectors Ordering example Type and version Switching temperature [°C] Tolerance [K] Lead length [mm] 1:1 Thermal-Protectors with insulation cap without insulation cap Contact type, normally closed / normally open Nominal switching temperature (NST) in steps of 5 °C Standard tolerance Reset temperature range below NST Operating voltage … AC / DC - available, values on inquiry Rated voltage UAC Rated current AC cos ϕ = 1.0 (ohmic load) / switching cycles Rated current AC cos ϕ = 0.6 acc. to IEC 60730-2-9 / switching cycles Rated current AC cos ϕ = 0.4 - 0.5 acc. to IEC 60730-2-3 / switching cycles Max. switching current at 250V ~ / cos ϕ = 0.4 - 0.5 / switching cycles Contact bounce time Contact resistance (acc. to MIL-Std. R 5757) Impregnation resistance with- or without resin (acc. to requirements)* Vibration proof at 10 … 60 Hz Pressure stability of housing * High voltage insulation (not C - versions) Suitable for predection class I or II Standard wiring connection Diameter (with / without insulation cap) Ød [mm] Heigth (with / without insulation cap) h [mm] Length of insulation cap l [mm] Length of housing l / b [mm] Length of Pin lp [mm] Screw / -length Wrench size / max. turning moment Approvals available (according to design) ** Automatic resetting, with connection leads Automatic resetting, with connection leads High Temperature Series Automatic resetting, with connection leads 1.6 A / 10,000 < 1 ms < 50 mΩ suitable 100 m/s² 150 N 1.450 V suitable Lead wire 0.25 mm² 10.1 mm 4.0 mm IEC; ENEC; VDE; UL 1.6 A / 1,000 < 1 ms < 50 mΩ suitable 100 m/s² 450 N 2 kV suitable AWG 22 9.5 / 9.0 mm 5.3 / 4.8 mm 22 mm IEC; ENEC; VDE * acc. to Thermik test / ** please specify which approval is needed You will find a selection of the most common products in the following tables. The values given can vary in the event of certain designs. Special products are available upon request. Details regarding specific information, measurement methods, applications, licenses, et cetera can also be provided upon request. We reserve the right to technical changes in the course of further development.

 Open the catalog to page 1
Product tables-2

Automatic resetting, with two solid non insulated connection wires either vertical or horizontal N01 / NK1 / N02 Automatic resetting, with connection leads Automatic resetting, with connection cables and plastic housing Automatic resetting, with connection leads Automatic resetting, single / or on tape with crimp contacts suitable for automated further processing Automatic resetting, single / or on tape with Pins for direct mounting on PCBs 1.6 A / 10,000 1.8 A / 10,000 (N01 / NK1) 7.2 A / 1,000 (N01 / NK1) < 1 ms < 50 mΩ suitable 100 m/s² 450 N suitable Single wire 0.5 mm 10.0 mm 3.4 mm 14.0...

 Open the catalog to page 2
Product tables-3

Thermal-Protectors Ordering example Type and version Switching temperature [°C] Tolerance [K] Lead length [mm] Thermal-Protectors with insulation cap without insulation cap Contact type, normally closed / normally open Nominal switching temperature (NST) in steps of 5 °C Standard tolerance Reset temperature range below NST Operating voltage … AC / DC - available, values on inquiry Rated voltage UAC Rated current AC cos ϕ = 1.0 (ohmic load) / switching cycles Rated current AC cos ϕ = 0.6 acc. to IEC 60730-2-9 / switching cycles Rated current AC cos ϕ = 0.4 - 0.5 acc. to IEC 60730-2-3 / switching...

 Open the catalog to page 3
Product tables-4

Examples of Typical Applications Approvals / Licenses VDE according to EN 60730 Electrical-self-hold-functionality defined current sensitive by an eligible integrated series resistor, with connection leads CW1 / SW1 SW1 CW1 NC 70 °C - 160 °C ± 5K depends on NST 100 V up to 250 V ~ 250 V 9.0 A / 1,000 1.6 A / 1,000 < 1 ms < 50 mΩ 100 m/s² 2 kV suitable Single wire Ø 0.5 mm / AWG 22 9.4 mm / 9.0 mm 5.6 mm / 5.1 mm 19.0 mm IEC; VDE Automatic functionality as per IEC/EN 60730 -1: 2BM/2CM Existing norm appendices for IEC/EN 60730: -1; -2-3; -2-9 B = Micro cutoff C = Micro interruption 2 = Defined...

 Open the catalog to page 4
Product tables-5

Thermal-Protectors Ordering example Type and version Switching temperature [°C] Tolerance [K] Lead length [mm] 1:1 Thermal-Protectors with insulation cap without insulation cap Contact type, normally closed / normally open Nominal switching temperature (NST) in steps of 5 °C Standard tolerance Reset temperature range below NST Operating voltage … AC / DC - available, values on inquiry Rated voltage UAC Rated current AC cos ϕ = 1.0 (ohmic load) / switching cycles Rated current AC cos ϕ = 0.6 acc. to IEC 60730-2-9 / switching cycles Rated current AC cos ϕ = 0.4 - 0.5 acc. to IEC 60730-2-3 / switching...

 Open the catalog to page 5
Product tables-6

High Temperature Series Automatic resetting, with connection leads C06 / S06 S06 C06 NC 205 °C - 250 °C ± 10K 125° C / ± 15K up to 500 V ~ 250 V 10 A / 1.000 6,3 A / 1.000 < 1 ms < 50 mΩ suitable 100 m/s² 600 N 2 kV suitable AWG 18 9,8 / 9,3 mm 7,6 / 7,2 mm 24 mm IEC; ENEC; VDE Automatic resetting with connection leads and insulation cap F06 F06 NC 70 °C - 200 °C ± 5K depends on NST up to 500 V ~ 250 V (VDE) 277 V (UL) 10,0 A / 10.000 25,0 A / 2.000* 6,3 A / 10.000 < 1 ms < 50 mΩ suitable 100 m/s² 600 N 2 kV suitable AWG 18 9,7mm 7,3mm IEC; ENEC; VDE; UL; CSA; CQC Automatic resetting, with threaded...

 Open the catalog to page 6
Product tables-7

Thermal-Protectors Ordering example Type and version Switching temperature [°C] Tolerance [K] Lead length [mm] 1:1 Thermal-Protectors with insulation cap without insulation cap Contact type, normally closed / normally open Nominal switching temperature (NST) in steps of 5 °C Standard tolerance Reset temperature range below NST Operating voltage … AC / DC - available, values on inquiry Rated voltage UAC Rated current AC cos ϕ = 1.0 (ohmic load) / switching cycles Rated current AC cos ϕ = 0.6 acc. to IEC 60730-2-9 / switching cycles Rated current AC cos ϕ = 0.4 - 0.5 acc. to IEC 60730-2-3 / switching...

 Open the catalog to page 7
Product tables-8

Examples of Typical Applications • normally closed (with electrical-self-hold-functionality) CR6, SR6 • normally open C09, S09, L09, C08, S08, L08, P08, H08, V08 Approvals / Licenses VDE according to EN 60730 Automatic resetting, for star point connection to protect a three phase motor CY6 / SY6 SY6 CY6 NC 70 °C - 180 °C ± 5K depends on NST up to 480 V ~ 3 x 440 V / 50/60 Hz 2.5 A / 10y000 6.3 A / 3y000* 1.6 A / 10y000 < 1 ms < 50 mΩ suitable 100 m/s² 600 N 2 kV suitable Lead wire 0,5 mm² / AWG20 9.8 mm / 9.3 mm 7.6 mm / 7.2 mm 17.0 mm UL; CSA Automatic functionality as per IEC/EN 60730 -1: 2BM/2CM...

 Open the catalog to page 8

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.