Catalog excerpts
1000 BTUH | INDOOR/OUTDOOR, UL TYPES 12, 4 & 4X AVAILABLE Engineered & manufactured to endure the most difficult of environments and applications. Thermal Edge air conditioners will exceed environmental requirements in applications like Steel, Food Processing, Petro-Chemical, Cement, Paper & Pulp and Plastics Digital Temperature Controller • Programmable set point and temperature controls • Visible Error and/or alarm messaging • System status indication & keypad lockout function Active Condensate Evaporation System • Constant elimination of condensate • Increases unit efficiency by pre-cooling refrigerant • Sloped top to allow for water runoff • Designed with rigid chassis and seam welded shroud • Thoughtful interior design for easy maintenance • Narrow body style fits on 12” enclosure Unit Efficiency • Temperature operated condenser fan reduces power inrush and saves energy • Highly efficient rotary compressor • Fully insulated & sealed cabinet • Thermal Expansion Valve to maintain cooling capacity over a broad ambient temperature range Compressor Protection System • Dry Contact Alarm Capabilities • High & Low refrigerant cutouts with fault indication • Open Door Kill Switch • Compressor anti short cycle protection • Corrosive Environment Packages • Compressor run capacitors reduce power inrush, save energy and increase compressor life • Remote Monitoring Options UL Type Voltage/ Phase/Hz. Running Amps Powder coated steel Powder coated steel Stainless steel Mill finish aluminum Powder coated steel Powder coated steel Stainless steel Mill finish aluminu
Open the catalog to page 1Testing done under controlled conditions. Actual performance may vary. TERMINAL BLOCK COVER OUTDOOR OPTION STRAIN RELIEF 2.00 CLEARANCE RIGHT; 2.50 CLEARANCE BELOW 1.810 POWER TERMINAL BLOCK (COVER NOT SHOWN) POWER SWITCH OUTDOOR OPTION TEMPERTURE CONTROLLER CORD FEED-THRU DRY CONTACT OPTION CORD FEEDTHRU Th EASY HANG TABS TERMINAL BLOCK COVER 22.01 DIGITAL TEMPERATURE CONTROLLER FRONT FILTER SERVICE MINIMUM ACCESS 8.23" FILTER ACCESS AND EXTRACTOR, FRONT SIDE SERVICE STANDARD 2.50 INLET CLEARANCE AMBIENT AIR (ENTERS FROM BELOW) WASHABLE FILTER GASKET LOCATION CUTOUT DIMENSIONS AS VIEWED...
Open the catalog to page 2All Thermal Edge catalogs and technical brochures
-
Enclosure Accessories
8 Pages
-
PLASTIC FILTER FAN PACKAGES
2 Pages
-
NE040D48
2 Pages
-
TM061
2 Pages
-
HC20C
2 Pages
-
HC201
2 Pages
-
HC151
2 Pages
-
HC121
2 Pages
-
NE080
2 Pages
-
NE060
2 Pages
-
NE050
2 Pages
-
NE040
2 Pages
-
NE015
2 Pages
-
CS011D48
2 Pages
-
MFFP
2 Pages
-
A2W30
2 Pages
-
Enclosure-Air-Conditioners
4 Pages
-
CS011
2 Pages
-
KTO-111-KTS-111
1 Pages