Catalog excerpts
Aquatherm RQT Standard Temperature Controller Tilted Front Panel Conveniently angled for optimal viewing, quick and easy monitoring and adjustment of the set point and other control functions. Pressure Gauges Large easy-to-read supply and return water pressure gauges located on the top of the unit provide easy monitoring of the mold circuit and unit performance. Intelligent Air Purge with 120°F Air Purge Cancel At start-up our automatic air purge sequence deactivates when the mold circuit is above 120°F to avoid cooling of the mold during temporary power interruptions. Standard Features High-Flow Pumps Designed to meet the rapid cooling requirements of injection mold cooling, our energy-efficient pumps provide the best flow available in the industry. Sizes are ¾ HP and 2 HP. Silicon carbide pump seals are standard. Long-Life Heaters Incoloy sheathed heater elements provide for the best combination of performance and longevity with better corrosion resistance than copper or stainless steel heaters. Leak-Proof Pump/Heater Assembly Heavy-duty cast-iron pumps, heater tubes, and mixing tubes with O-ring seals reduce threaded fittings that can cause internal pressure losses and are prone to leaks. Long-Life Pump Seals/Internal Flushing System High-temperature pump seals, with an integral flush system and turbulence ribs inside the seal chamber, extend seal life and are more energy efficient than external seal flush lines. High-Performance Solenoid Valves Fast-acting solenoid valves respond quickly and precisely to any sudden changes in the process and ensure consistent mold temperatures all the time. 24 VDC Control-Circuit Power Dependable and safe control circuit power, isolates the control circuit from static interference for stable and precise operation. Standard PLC Controller Controller Easy to use LCD screen with adjustable parameters offers exact temperature control. Data includes: Set point and actual temperature Pump running hours display Temperature deviation alarms and warnings Adjustable alarm delay time Tracks heater contactor life Machine diagnostics Selectable control tuning levels Pump and Heater Running Hours Display Running hour meters for both pump and heater provide a quick and easy way to check on total machine run time to better plan for routine maintenance. Temperature Deviation Warnings and Alarms Provides a visual alert of a potential problem before a fault occurs. If the condition worsens, the alarm sounds and the unit stops to preve
Open the catalog to page 1Aquatherm RQT Standard Temperature Controller Adjustable Deviation Alarm Time Delays A programmable alarm time delay eliminates nuisance alarms at start-up by allowing the unit to reach a stable temperature before activating the temperature alarms. Supply and Return Temperature Display Continuous display of the set point and supply temperatures and ability to check the return temperature for complete monitoring of the process and unit operation. The standard set point range is 40°F to 250°F. Available Options Mold Purge Quickly evacuates fluid from the process circuit and depressurizes,...
Open the catalog to page 2Aquatherm RQT Standard Temperature Controller 5680 W. Jarvis Ave • Niles, IL 60714 847-966-2260 • sales@thermalcare.com www.thermalcare.com August 2022 Thermal Care is ISO-9001 Certified Manufacturer reserve the right to change specification or design without notification or obligation RQT Standard Specification 0
Open the catalog to page 3All Thermal Care catalogs and technical brochures
-
Water Treatment Systems
4 Pages
-
Pump Systems PT Series
4 Pages
-
Temperature Controllers
4 Pages
-
Outdoor Chillers
4 Pages
-
Central Chillers
7 Pages
-
Portable & Packaged Chillers
4 Pages
-
Portable & Packaged Chillers
4 Pages
-
Accuchiller NQV
5 Pages
-
Accuchiller NQ
7 Pages
-
Portable Chillers
4 Pages
-
Pump Tanks
2 Pages