The Accuchiller TSE Central Chiller is designed for industrial cooling applications, offering both single and dual-circuit configurations for flexibility and reliability.
Standard Features:
  • Direct Drive Scroll Compressors: Hermetically sealed for efficient, low-maintenance operation.
  • Stainless Steel Evaporator: Features high-efficiency plates with copper brazing for durability.
  • Evaporator Inlet Strainer: Prevents debris from clogging, reducing downtime.
  • Compact Design: Fits through standard 36-inch doors for chillers up to 80 tons.
  • Modular System: Expandable to over 1,000 tons with multiple chillers and circuits.
  • UL 508A Control Panel: Ensures safety and reliability.
  • Color Touch-Screen Display: 7-inch screen for easy monitoring and control.
  • CONNEX4.0 Ready: Ethernet compatibility for plant-wide control.
  • Warranty: 1-year parts and labor coverage.
Available Options:
  • Integral Reservoir and Pumping System: Available for chillers up to 160 tons for quick installation.
  • Rotary Non-Fused Disconnect Switch: Enhances safety with a 5 kA SCCR rating.
  • 12-inch HMI: Offers remote monitoring and control.
  • BACnet or Lon Works Communications Port: Adds connectivity options.
Technical Specifications:
  • Cooling Capacity: 10 to 256 tons depending on model and configuration.
  • Set Point Range: 20°F to 80°F.
  • Dimensions and Weight: Vary by model.
  • Electrical Requirements: MCA and MOP values specified for safe operation.
Remote Condensers (Dual-Circuit) Specifications:
  • Models: KCM034 to KCL224.
  • Compatible Chillers: TSER020D to TSER160D.
  • Number of Fans: 4 to 12 depending on model.
  • Refrigerant Inlet/Outlet Sizes: Varies by model.
  • Dimensions: Length 83 to 333 inches, Width 87 inches, Height 54 inches.
  • Weight: Shipping weight 830 lbs to 4,400 lbs.
  • Electrical Specifications: MCA 5 to 46 amps, MOP 15 to 50 amps at 460/3/60.
Manufacturer Information:
  • Manufactured by Thermal Care, ISO 9001 Certified.
  • Specifications subject to change without notice.
  • Contact: 5680 W. Jarvis Ave, Niles, IL 60714, Phone: 847-966-2260, Email: [email protected], Website: www.thermalcare.com
Note: Emphasizes the importance of MCA for minimum wire size requirements and MOP for sizing main power protection devices.
See more

Catalog excerpts

Accuchiller TSE Central Chiller-1

Accuchiller TSE Central Chiller Modular Expandable System Our modular system design provides for system expansion to over 1,000 tons using up to six chillers and twelve refrigeration circuits. Single or Multiple Circuit Configurations Dual-circuit chillers for redundancy and back up of critical processes or systems and single-circuit chillers for dedicated loads. UL 508A Industrial Control Panel Every chiller has a UL label certifying our panel design and components comply with UL 508A standards ensuring the panels are safe and consistent for reliable operation. Color Touch-Screen Display A high-resolution, high-speed, 7-inch color touch-screen with English text clearly shows chiller operation for quick and easy monitoring and control of the system. Single-Circuit Chiller Standard Features Direct Drive Scroll Compressors Direct-drive hermetically sealed scroll compressors with proven performance in industrial cooling for reliable, low maintenance, and efficient operation. Stainless Steel Evaporator High-efficiency stainless steel plates with copper brazing provide maximum performance, long life, and an enhanced level of protection from harsh process conditions. Evaporator Inlet Strainer The evaporator inlet strainer removes any debris present in the process fluid to prevent costly downtime and repair due to a clogged chiller evaporator. Fits through Doors Single circuit chillers up to 80 tons are compact and easily fit through standard 36-inch wide doors for easy maneuvering into tight installation spaces. Dual Circuit Manifolds Dual circuit chillers include evaporator manifolds and water-cooled condenser units include condenser water manifolds for quick and easy installation. Standard PLC Home Screen CONNEX4.0 Ready Controls Every chiller is equipped with an Ethernet port and is fully compatible with the CONNEX4.0 plant-wide equipment control and monitoring system. Warranty 1 year entire unit parts 1 year la

 Open the catalog to page 1
Accuchiller TSE Central Chiller-2

Accuchiller TSE Central Chiller Available Options Integral Reservoir and Pumping System An integral stainless steel reservoir and pumping system all piped, insulated, and wired to the chiller control panel for a quick and easy complete chilled water system installation. Available on chillers up to 160 tons. Rotary Non-Fused Disconnect Switch Adds a 5 kA SCCR (Short Circuit Current Rating) rotary non-fused disconnect switch to the control panel for safe lockout of main power. 12 inch HMI Replaces the standard 7-inch screen with a 12-inch, high resolution, color screen with a built-in industrial...

 Open the catalog to page 2
Accuchiller TSE Central Chiller-3

Accuchiller TSE Central Chiller Water-Cooled Condenser Single-Circuit Chillers TSEW 010S Cooling Capacity (tons)1 Set Point Range (°F) Compressors (qty) w/high flow evaporator option Process In/Out (in) – Standard Ship Weight (lbs) Operating Weight (lbs) Process Connection Size (in) Chiller with Standard Flow Reservoir Option Reservoir Capacity (gal) Process / Chiller Pump (hp) 4 114 The TSEW100S and TSEW120S are not 101 available with an 73 integral reservoir 4,370 Chiller with High Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Condenser...

 Open the catalog to page 3
Accuchiller TSE Central Chiller-4

Accuchiller TSE Central Chiller Water-Cooled Condenser Dual-Circuit Chillers TSEW 020D Cooling Capacity (tons)1 Process In/Out (in) – Standard w/high flow evaporator option Condenser Water In/Out (in) Process Connection Size (in) Condenser Water In/Out (in) Chiller with Standard Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) 6 148 The TSEW200D and TSEW240D are not 1114 available with an 90 integral reservoir 8,168 Chiller with High Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Condenser Water In/Out (in) 6 148 The...

 Open the catalog to page 4
Accuchiller TSE Central Chiller-5

Accuchiller TSE Central Chiller Remote Air-Cooled Condenser Single-Circuit Chillers TSER 010S Cooling Capacity (tons)1 Set Point Range (°F) Compressors (qty) Process In/Out (in) – Standard w/high flow evaporator option Refrigerant Discharge Line (in) Refrigerant Liquid Line (in) Chiller with Standard Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Refrigerant Discharge Line (in) Refrigerant Liquid Line (in) Chiller with High Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Refrigerant Discharge...

 Open the catalog to page 5
Accuchiller TSE Central Chiller-6

Accuchiller TSE Central Chiller Remote Air-Cooled Condenser Dual-Circuit Chillers TSER 020D Cooling Capacity (tons)1 Process In/Out (in) – Standard w/high flow evaporator option Refrigerant Discharge Line/Circuit (in) Refrigerant Liquid Line/Circuit (in) Chiller with Standard Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Refrigerant Discharge Line/Circuit (in) Refrigerant Liquid Line/Circuit (in) Chiller with High Flow Reservoir Option Reservoir Capacity (gal) Process/Chiller Pump (hp) Process Connection Size (in) Refrigerant Discharge Line/Circuit...

 Open the catalog to page 6
Accuchiller TSE Central Chiller-7

Accuchiller TSE Central Chiller Remote Condensers (Single-Circuit) Model Chiller Used With Varies based on system refrigerant charge and operating conditions MOP @ 460/3/60 (amps)2 15 15 15 15 15 1 MCA is Minimum Circuit Amps, used for minimum wire size requirement. 2 MOP is Maximum Overcurrent Protection, used for sizing main power protection device. Remote Condensers (Dual-Circuit) Model Chiller Used With Varies based on system refrigerant charge and operating conditions 21 MOP @ 460/3/60 (amps)2 15 20 20 20 25 1 MCA is Minimum Circuit Amps, used for minimum wire size requirement. 2 MOP is...

 Open the catalog to page 7
Accuchiller TSE Central Chiller-8

Accuchiller TSE Central Chiller 5680 W. Jarvis Ave • Niles, IL 60714 847-966-2260 • [email protected] www.thermalcare.com May 2022 Thermal Care is ISO 9001 Certified Manufacturer reserve the right to change specification or design without notification or obligation TSE Specifications 1

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.