T20 Load cell Data sheet
2Pages

{{requestButtons}}

Catalog excerpts

T20 Load cell Data sheet - 1

T20 LOW PROFILE WEIGHING ASSEMBLY FOR SILO, TANK AND VESSEL WEIGHING capacities 1t to 30t Image shows T20 load cell installed within LA20 mounting accessory (2 capacity ranges) The T20 Weighing Assembly is specifically designed as a reliable, simple, low cost solution for weighing of tanks, silos and vessels where ‘level measurement’ is the main requirement. It offers an excellent compromise between accuracy and cost. The stainless steel T20 load cell is mounted in either a zinc plated or stainless steel, compact LA20 mounting accessory that has integral jacking bolts to allow for load cell installation and removal, lift-off prevention and allowance for the angular misalignment that is often present in silos or other metal structures. The LA20 accessory incorporates a hardened alloy steel or stainless steel load bearing surface, for optimum force application to the T20 load cell. The design is suitable for use either as a totally live system with load cells under all legs/support points of the vessel or – where cost is critical – as a dummy system with either one live and two dummy cells (total 3 cells) or two live and two dummy cells (total 4 cells). ■ Stainless steel compression load cell ■ Low profile, extremely compact mounting accessory ■ Fully welded and hermetically sealed construction to IP68/IP69K ■ Integral lift-off prevention ■ Allows for thermal expansion and contraction of vessel ■ Integral jacking facility to lift accessory ■ 1000 division accuracy ■ ■ Allowance for angular mis-alignment ■ 5 year warranty ■ Durable polyurethane cable with high resistance to chemicals, impacts and UV radiation ■ Optional Parylene coating for aggressive envi

Open the catalog to page 1
T20 Load cell Data sheet - 2

technical specification... SIDE VIEW Mounting Proposals Mounting dimensions (upper and lower): G x J Dimensions Load cell specification Combined Error Load Cell Capacity (E max ) Rated Output (S n ) Minimum load cell verification interval (vmin ) = E max / Y Creep (30 minutes) Temperature Effect on Zero Balance Compensated Temperature Range Operating Temperature Range Safe Load Limit (E lim ) Zero Balance Input Resistance Output Resistance Temperature Effect on Span Insulation Resistance Environmental Protection according to EN 60529 Cable Length Nominal Shipping Weight (Load Cell with...

Open the catalog to page 2

All Thames Side Sensors catalogs and technical brochures