Overview: The T12 is a stainless steel single point load cell designed for harsh environments, offering high accuracy weight measurement with off-centre loads. It is suitable for industrial applications such as food and pharmaceutical industries due to its hermetically sealed and fully welded construction, providing protection class IP68 and IP69K.
Specifications:
  • Capacities range from 15kg to 400kg.
  • Rated Output: 2 mV/V ± 0.1%.
  • Accuracy Class: 3000 divisions OIML R60 Class C up to 350 kg.
  • Combined Error: < ± 0.017% Sn.
  • Temperature Range: Compensated -10 to +40°C, Operating -20 to +70°C.
  • Safe Overload: 150% Sn, Ultimate Overload: 200% Sn.
  • Environmental Protection: IP68 and IP69K.
Applications: Suitable for weighing platforms up to 800mm x 800mm, bagging, filling, dosing machines, medical scales, checkweighers, and small bucket and hopper systems.
Features:
  • Optional ATEX certification for all Gas and Dust zones, with cost-saving features for dust zones 20, 21, and 22.
  • Special Parylene coating available for aggressive environments.
  • 5-year warranty.
Technical Details:
  • Electrical Connections: 6-wire, 5.7mm diameter, screened polyurethane cable.
  • Input Resistance: 400 Ω ± 20, Output Resistance: 350 Ω ± 3.
  • Insulation Resistance: > 5000 MΩ @ 100V.
  • Recommended Supply Voltage: 5-15 V, Maximum Supply Voltage: 15 V.
Dimensions: Detailed dimensions provided for various capacities, with specific mounting instructions.
ATEX Certification: Includes protection types for gas and dust zones, with specific parameters for safety.
See more

Catalog excerpts

T12 Load cell Data sheet-1

T12 STAINLESS STEEL SINGLE POINT LOAD CELL FOR HARSH ENVIRONMENTS capacities 15kg - 400kg The T12 double bending beam, stainless steel single point load cell is ideal for high accuracy weight measurement with off-centre loads in harsh industrial environments. Its hermetically sealed and fully welded construction, with protection class IP68 and IP69K, is essential for use in applications involving regular washdown at high temperatures and pressures, such as the food and pharmaceutical industries. It is approved to 3000 divisions OIML R60 Class C up to 350 kg. The screened polyurethane cable with 6-wires (including sense wires) ensures that this load cell design is particularly insensitive to electrical noise. Typical applications include weighing platforms with dimensions up to 800mm x 800mm; bagging, filling and dosing machines; medical scales; checkweighers; small bucket and hopper systems. The T12 is available with optional ATEX certification for all Gas and Dust zones. The ATEX certification for dust zones 20, 21 and 22 does not require safety barriers, which saves substantial cost. For applications in aggressive environments where stress corrosion or acid attack is a potential problem, a special Parylene coating can be specified as an option. ■ Stainless steel load sensor ■ Hermetically sealed and fully welded to IP68 and IP69K ■ OIML R60 Class C 3000 divisions (C3) ■ Rated Output (Sn) tolerance is ± 0.1 % as standard ■ ■ 5 year warranty ■ High accuracy with off-centre loads ■ 600x600mm or 800x800mm platform size (with load cell placed centrally under the platform) ■ High durability Polyurethane cable provides higher resistance to chemicals than PVC

 Open the catalog to page 1
T12 Load cell Data sheet-2

I E Qty. 2 spacer plates supplied with load cell, as shown above Dimensions Load cell specifications Load Cell Capacities (E max) Rated Output (S n) Accuracy Class Combined Error Temperature Effect on Zero Balance Temperature Effect on Span Compensated Temperature Range Operating Temperature Range Safe Overload Ultimate Overload Input Resistance Output Resistance Minimum load cell verification interval (vmin) = Emax / Y Minimum Dead Load Zero Balance Maximum Deflection at Nominal Capacity Insulation Resistance Recommended Supply Voltage Maximum Supply Voltage Environmental Protection to EN 60529...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.