TECHNICAL DATA SHEET TS-I HV E SERIES TS-I HV 80 E | TS-I HV 100 E TECHNICAL DATA FOR BATTERY STORAGE SYSTEM TS-I HV 80 E TS-I HV 100 E Type designation Energy content Nominal voltage Cell balancing Cycles expected @ 100% DoD | 70% EoL | 23°C +/-5°C 1C/1C Cycles expected @ 100% DoD | 70% EoL | 23°C +/-5°C 0.5C/0.5C Efficiency (battery) Self-consumption (standby) Operating temperature Ambient temperature Cooling concept Altitude of installation site Weight Total Weight Cabinet Battery module Battery management system (APU) Lithium NMC prismatic (Samsung SDI) DynamiX Battery Optimizer 6000 5 W (without battery inverter) 0°C to 50°C 0 to 80% (non-condensing) Passive via fins and active via fans Tilt height Certificates/standards Cell Guarantee Recycling Protection class Protection class 2155 mm (front/back)/ 2090 mm 2358 mm (front/back)/ 2160 mm (lateral) (lateral) 10-year performance guarantee, 5-year system guarantee TESVOLT offers a free take-back scheme for batteries from Germany
Open the catalog to page 1This table displays the possible output depending on the energy and the number of battery inverters and modules. Quantity Energy TS HV 90/ system 10-20 [kWh] A connection to the low-voltage grid according to VDE AR-N 4105 must be coordinated with the local energy supplier. With eight or more TS HV 90 pro TESVOLT PCS, an external DC combiner is required. This is not part of TESVOLT's scope of delivery and must be configured on a project-specific basis.
Open the catalog to page 2This table displays the possible output depending on the energy and the number of battery inverters and modules. Quantity Energy TS HV 90/ system 12-20 [kWh] A connection to the low-voltage grid according to VDE AR-N 4105 must be coordinated with the local energy supplier. With eight or more TS HV 90 pro TESVOLT PCS, an external DC combiner is required. This is not part of TESVOLT's scope of delivery and must be configured on a project-specific basis.
Open the catalog to page 3TECHNICAL DATA FOR TESVOLT PCS BATTERY INVERTER 1 independent power unit (IPU) Rated active power Rated apparent power Rated AC current Rated DC current DC short-circuit current (< 1 s) Operating voltage AC Grid frequency DC voltage range Dimensions (H x W x D) Tilt height Max. efficiency Operating temperature Weight Protection class Certificates and permits Noise level approx. 390 kg approx. 530 kg approx. 670 kg approx. 820 kg Modbus TCP/IP Transformer-free Am Heideberg 31 | 06886 Lutherstadt Wittenberg Germany TNs project hai received fuvcfng from ttie European LMon': Hoftron 2020 rowarcti...
Open the catalog to page 49 Pages
8 Pages
6 Pages
6 Pages
2 Pages
3 Pages
4 Pages
2 Pages
2 Pages