The digital clamp meters Testboy TV 215 and TV 216 are each respectively equipped with a clearly readable display and bargraph. The manual or automatic range selector enables safe working in a wide range of applications. The plastic case included in the range of supply reliably protects the device and accessories even during transport. Our TV 215 and 216 are the right choice for service tasks, in industry and installation tasks. Your advantages: | 5 years manufacturer’s warranty | TÜV / GS tested and approved | IEC/EN 61010-1, DIN VDE 0411 Technical Details Testboy TV 215 Testboy TV 216 Display 3½ digit LCD, 1999 counts 4digit LCD, 6599counts AC Current 2, 20, 200, 600A, 50 to 60Hz 60A, 600A, 40 to 400Hz Accuracy ±3,5%+20digit under 0,5A / ±3,0%+10digit till 20A / ±3,0%+10digits overall ±2,5%+10digit till 200A / ±1,5%+5digit till 600A Highest Resolution 1mA 10mA DC current -/- 60A, 600A Accuracy -/- ±3,0% +10digit overall Highest Resolution -/- 10mA AC voltage 200mV, 2, 20, 200, 600V, 40 to 200Hz 600mV, 6, 60, 600V, 40 to 400Hz Accuracy ±0,1%+10digit till 200mV / ±1,0%+5digit till 200V / ±1,2%+5digit till 600V ±1,5%+10digit till 600mV / ±1,2%+5digit till 60V / ±1,5%+10digit till 600V Highest Resolution 1mV 100µV Input Impedance 10MΩ 10MΩ DC voltage 200mV, 2, 20, 200, 600V 600m, 6, 60, 600V Accuracy ±0,8%+2digit till 200V / ±1,0%+2digit till 600V ±0,8%+3digit till 60V / ±1,0%+5digit till 600V Highest Resolution 100µV 100µV Input Impedance 10MΩ 10MΩ Frequency by clamp -/- 600Hz, 1kHz, >1A AC rms Accuracy -/- ±1,5%+5digit till 1kHz
Open the catalog to page 1Highest Resolution -/- 100mHz Frequency by plugs -/- 600Hz, 6kHz, 10kHz, >0,2V AC rms Accuracy -/- ±1,5%+5digit till 10kHz Highest Resolution -/- 100mHz Duty Cycle -/- 10 to 95%, ±3,0%, >1A AC rms -/- 10Hz to 1kHz 200, 2k, 20k, 200k, 2M, 20MΩ 600, 6k, 60k, 600k, 6M, 60MΩ ±1,2%+2digit till 2MΩ ±1,2%+2digit till 6MΩ ±2,0%+5digit at 20MΩ ±2,0%+5digit till 60MΩ Frequency response Resistance Accuracy Highest Resolution 100mΩ 100mΩ Diodetest forward current ~1mA, drop voltage ~1,5V forward current ~1mA, drop voltage ~3,3V Resolution 1mV 1mV Continuity test buzzer if resistance under 60Ω buzzer if resistance...
Open the catalog to page 284 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages