The Model 341 electrical force transducers utilize sputtered strain gauge technology to achieve high accuracy. They are designed with a flat profile and small dimensions, offering high long-term zero point stability and low hysteresis. These transducers are ideal for tensile and compressive measurements in small measuring ranges, with applications in medical instrumentation, robotics, and food dispensing equipment.
Specifications
  • Capacities range from 0.5N to 125N.
  • Features include very small dimensions, suitability for compression and tension, and modern technology with sputtered strain gauges.
  • Sensitivity is rated at 1mV/V.
  • An optional TEDS module can be installed inside the plug.
Technical Parameters
  • Hysteresis: 0.03%
  • Long-term stability: 0.1% per year
  • Zero signal when removed: 1 mV/V
  • Rated characteristic value: 1 mV/V
  • Relative linearity error: ≤ 0.05%
  • Non-repeatability: ≤ 0.05%
  • Combined error: ≤ 0.058%
  • Operating temperature range: -10°C to +70°C
  • Temperature effect on characteristic value per 1K: ≤ 0.03%
  • Temperature effect on zero signal per 1K: ≤ 0.03%
  • Input and output resistance: 1000 Ω
  • Insulation resistance: > 1000 MΩ
  • Max. excitation voltage: 15 V
  • Recommended excitation voltage: 10 V
  • Limit force: ≤ 200%
  • Breaking force: ≥ 500%
Dimensions and Deflection
  • Dimensions are consistent across capacities, with specific measurements provided for each capacity level.
  • Deflection values vary by capacity, ranging from 0.229 mm for 10N to 0.432 mm for 125N.
Connection Details
  • Red wire: Excitation +
  • Yellow wire: Output +
  • Blue wire: Excitation -
  • Green wire: Output -
See more

Catalog excerpts

Model 341-1

Electrical Force Transducers – Model 341 n n n n n n n n The electrical force transducers of the model series 341 work by using a sputtered strain gauge technology and thereby they reach a high accuracy. They are characterised by their flat design with very small di- mensions, as well as by their high long term zero point stability and their low hysteresis. The highly sophisticated force transducers are excellently suitable for tensile and compressive measurements Capacities: 0,5N to 125N Very small dimensions For compression and tension Modern technology Sputtered strain gauges High accuracy Sensitivity: 1mV/V Optional: TEDS module 1) (Installation inside plug) in very small measuring ranges. Applications: Medical instrumentation, force, displacement and acceleration measurement, robotics, food dispensing equipment. Symbol Unit Long term stability Zero signal when removed Rated characteristic value Combined error Operating temperature range Relative creep Temperature effect on characteristic value per 1K Temperature effect on zero signal per 1K Relative linearity error Input resistance Output resistance Insulation resistance Recommended excitation voltage Limit force Breaking force 1) TEDS = Transducer Electronic Data Sheet acc. to IEEE 1451.4 TesT Deutschland: Helena-Rubinstein-Straße 4 | 40699 Erkrath | Fon: +49 211 2099030 | Fax: +49 211 209903201 | [email protected] | www.test-gmbh.com TesT Schweiz: Bösch 63 | 6331 Hünenberg | Fon: +41 41 7856010 | Fax: +41 41 7856015 | test@tes

 Open the catalog to page 1
Model 341-2

Electrical Force Transducers – Model 341 Dimensions in mm Model 341 Capacities TesT Deutschland: Helena-Rubinstein-Straße 4 | 40699 Erkrath | Fon: +49 211 2099030 | Fax: +49 211 209903201 | [email protected] | www.test-gmbh.com TesT Schweiz: Bösch 63 | 6331 Hünenberg | Fon: +41 41 7856010 | Fax: +41 41 7856015 | [email protected] | www.test-ag.ch

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.