Product catalog summary
Overview
The Model 340 electrical force transducers utilize sputtered strain gauge technology to achieve high accuracy. They are designed with a flat profile and small dimensions, offering excellent long-term zero point stability and low hysteresis. These transducers are ideal for tensile and compressive measurements in small measuring ranges, suitable for applications in medical instrumentation, robotics, and food dispensing equipment.
Specifications
  • Capacities: 0.2N and 0.4N
  • Sensitivity: 1mV/V
  • TEDS module available (installation inside plug)
  • Hysteresis: 0.03%
  • Long-term stability: 0.1% per year
  • Zero signal when removed: 1 mV/V
  • Rated characteristic value: 1 mV/V
  • Relative linearity error: ≤ 0.05%
  • Nonrepeatability: ≤ 0.05%
  • Combined error: ≤ 0.058%
  • Operating temperature range: -10°C to +70°C
  • Relative creep after 30 min: ≤ 0.05%
  • Temperature effect on characteristic value per 1K: ≤ 0.03%
  • Temperature effect on zero signal per 1K: ≤ 0.03%
  • Input and output resistance: 1000 Ω
  • Insulation resistance: > 1000 MΩ
  • Max. excitation voltage: 15 V
  • Recommended excitation voltage: 10 V
  • Limit force: ≤ 200%
  • Breaking force: ≥ 500%
Connection and Dimensions
  • Connection Drawing: Red (Excitation +), Yellow (Output +), Blue (Excitation -), Green (Output -)
  • Dimensions (in mm): A: 57.9, B: 48.0, C: 3.6, D: 23.4, E: 6.4, F: 66.0, G: 5.0, H: 5.0, I: 0.5
  • Deflection: 2.235 for 0.2N, 2.921 for 0.4N
See more

Catalog excerpts

340-1

Electrical Force Transducers – Model 340 n n n n n n n n The electrical force transducers of the model series 340 work by using a sputtered strain gauge technology and thereby they reach a high accuracy. They are characterised by their flat design with very small di- mensions, as well as by their high long term zero point stability and their low hysteresis. The highly sophisticated force transducers are excellently suitable for tensile and compressive measurements Capacities: 0,2N and 0,4N Very small dimensions For compression and tension Modern technology Sputtered strain gauges High accuracy Sensitivity: 1mV/V TEDS module available 1) (Installation inside plug) in very small measuring ranges. Applications: Medical instrumentation, force, displacement and acceleration measurement, robotics, food dispensing equipment. Symbol Unit Long term stability Zero signal when removed Rated characteristic value Relative linearity error Combined error Operating temperature range Temperature effect on characteristic value per 1K Temperature effect on zero signal per 1K Input resistance Output resistance Insulation resistance Relative creep Recommended excitation voltage Limit force Breaking force 1) TEDS = Transducer Electronic Data Sheet acc. to IEEE 1451.4 TesT Deutschland: Helena-Rubinstein-Straße 4 | 40699 Erkrath | Fon: +49 211 2099030 | Fax: +49 211 209903201 | [email protected] | www.test-gmbh.com TesT Schweiz: Bösch 63 | 6331 Hünenberg | Fon: +41 41 7856010 | Fax: +41 41 7856015 | [email protected] | www.test-ag.ch

 Open the catalog to page 1
340-2

Electrical Force Transducers – Model 340 Connection Drawing TesT Deutschland: Helena-Rubinstein-Straße 4 | 40699 Erkrath | Fon: +49 211 2099030 | Fax: +49 211 209903201 | [email protected] | www.test-gmbh.com TesT Schweiz: Bösch 63 | 6331 Hünenberg | Fon: +41 41 7856010 | Fax: +41 41 7856015 | [email protected] | www.test-ag.ch

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.