TEOS+ 100 6-10kVA
2Pages

{{requestButtons}}

Catalog excerpts

TEOS+ 100 6-10kVA - 1

HOME & OFFICE Advanced Digital Parallel Technology Auto Sensing Frequency POWER FACTOR SERVICE / TECH. SUPPORT G E N E R A L S P E C I F I C AT I O N S • Active power factor correction (APFC), input power factor up to 0.99 • High efficiency 95% (up to 98% in ECO mode) • Advanced digital parallel technology • Wide input voltage range (110 ~ 288 Vac) and frequency range (40 ~ 70 Hz) • 50 / 60 Hz frequency auto sensing • Two modes of frequency conversion: 50 Hz input / 60 Hz output or 60 Hz input / 50 Hz output • Intelligent battery management, automatic floating / equalizing charge control, charger dormancy control, increasing battery life by 50% • Settable delayed start time when mains power is restored, reducing the impact on power grid or generator • Fan speed varies intelligently with temperature, reducing noise and extending its service life • Equipped with self-aging function • Dual-input design, supporting independent bypass • Compact internal layout, miniaturized the complete unit for small footprint • Flexible battery configuration (settable 16 - 20 pcs batteries) • LCD+LED display, multi-functional keys operation, friendly human-machine • Digitally controlled charger • High charging current available (Max. 12 A) • Powerful background software for parameters configuration • Charging voltage and current configured by demands • Advanced multi-platform communications: RS232, USB, RS485, SNMP and dry • Linear derating in low voltage input reducing battery discharging times, extending the service life of battery • Ability to switch on the UPS with batteries contacts communication interfaces • Effective software and hardware protection function, robust self-diagnostic function, and abundant event log for check Av a i l a b l e O p t i o n s • RS232 and smart card slot included • Optional parallel function, battery temperature compensation, SNMP card, USB, RS485 card, dry contac

Open the catalog to page 1
TEOS+ 100 6-10kVA - 2

INPUT Input wiring Rated voltage Voltage range 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 288 Vac (no derating) Rated frequency Frequency range Power factor Bypass voltage range Total harmonic distortion (THDi) OUTPUT Output wiring Rated voltage Voltage regulation Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode Power factor 1.0 ≤ 1% (linear load); ≤ 4% (non-linear load) Total harmonic distortion (THDv) Crest factor Number of battery Inbuilt battery (standard model) Standard model: 1 A; Long time model: 5 A (default),1 ~ 5 A settable; 12 A...

Open the catalog to page 2

All Tescom catalogs and technical brochures

  1. XT100

    2 Pages

  2. ACCESSORIES

    4 Pages

  3. TEOS RT

    2 Pages

  4. TEOS 200

    2 Pages

  5. XT200

    2 Pages

  6. TEOS 300

    2 Pages

  7. DS POWER X

    2 Pages

  8. DS POWER XL

    2 Pages

  9. DS POWER

    2 Pages

  10. DS POWER SH

    2 Pages

  11. XT300

    2 Pages

  12. STS 2000

    2 Pages

  13. STS 4000

    2 Pages

  14. SD SERIES

    2 Pages

  15. TEOS+ 100

    2 Pages

  16. TEOS100

    2 Pages

  17. Leo

    2 Pages

  18. TEOS100xl

    2 Pages

  19. Leo+

    2 Pages