DATA CENTER MALLS & FACILITIES DS POWER 500-600kW Transformerless UPS Topology IGBT Rectifier DSP Control SERVICE / TECH. SUPPORT POWER FACTOR DS Power range UPS uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision. G E N E R A L S P E C I F I C AT I O N S • Low input current total harmonic distortion (THD) • Small footprint • Ecomode operation (optional) • High input power factor • Fewer electronic components • Output current limiting • Cold start function • Advanced diagnostics for the input • Static and maintenance by-pass switch • Selectable input/output voltage/frequency/range • Output short circuit and overload protection • Split by-pass input (second input) • External REPO switch input • Output DC leakage protection • 512 events memory (512 events 45000 alarms) • Seperate DSP for inverter control • Clock and calender (battery supported) • Automatic battery test,remaining battery time indicator • 3 level battery protection • Temperature compansated charge system (optional) • High charge current capacity • 2 RS232 serial ports and 12 dry contact outputs • Charge/discharge current indicator • 3 DSP controlled modular structure • Advanced remote control features • Optional SNMP and MODBUS adaptors • Manufactured according to EC Directive; EN62040 • Optional graphical panel

Open the catalog to page 1
DS POWER - 2

INPUT Voltage Power factor (@100% load) By-pass voltage Protection 380/400 VAC 3P + N, ± 10% Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator OUTPUT Power (kW) Power factor Voltage Frequency Frequency tolerance Efficiency (@100% load) Crest factor 600 1.0 380/400 VAC 3 Phase + N, ± 1% (415 VAC optional) 50Hz / 60Hz Line synchronized: ± 2% / Free running: ± 0.1% up to 95% 3:1 Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load,...

Open the catalog to page 2

All Tescom catalogs and technical brochures

  1. XT100

    2 Pages

  2. ACCESSORIES

    4 Pages

  3. TEOS RT

    2 Pages

  4. TEOS 200

    2 Pages

  5. XT200

    2 Pages

  6. TEOS 300

    2 Pages

  7. DS POWER X

    2 Pages

  8. DS POWER XL

    2 Pages

  9. DS POWER SH

    2 Pages

  10. XT300

    2 Pages

  11. STS 2000

    2 Pages

  12. STS 4000

    2 Pages

  13. SD SERIES

    2 Pages

  14. TEOS+ 100

    2 Pages

  15. TEOS100

    2 Pages

  16. Leo

    2 Pages

  17. TEOS100xl

    2 Pages

  18. Leo+

    2 Pages