TESA TECH NOLOGY Inductive probes application Probe interface with Programmable Logic analogue output Controller (PLC) The probe interface allows to connect 4 TESA inductive probes and convert the signal of the probes to analogue DC outputs connectable to: - Programmable Logic Controller (PLC) - A/D converters for data acquisition by a PC Particularly suitable for multi-gauging installations, these robust interfaces can be used directly for applications up to 4 probes or can be assembled on a DIN rail for larger applications with an easy integration. UNIQUE FEATURES: - EASY AND FAST INTEGRATION ON DIN RAILS - FAST RESPONSE TIME - ROBUST METALLIC CONSTRUCTION - COMPATIBLE WITH LARGE RANGE OF TESA PROBES
Open the catalog to page 1Signal output (Sub D 9p-Female) Rail DIN 35 x 7,5 mm Power supply 100-240 V / 50-60 Hz to 15 VDC Output type IEC 60320 C14 1 Output probe channel 1 2 Output probe channel 2 4 Output probe channel 3 5 Output probe channel 4 Choose external power supply or power supply 04130323 (not both) 0,1 A needed for each interface
Open the catalog to page 2NOMINAL output signal for 100 pm stroke from 0 with gain = 1 V/mm (adjustable to 2,5, 5 or 10 - see user manual) Multigauge application with FMS probes
Open the catalog to page 3- Power supply: - Probe connection type: - Gain adjustment presetting: - Error: ± 0,5 % of the measuring range ACCESSORIES FOR POWER SUPPLY 04760153 Part number 03160016 03160015 03160017 Mains cable type EU CH Universal with flying leads ©2026 TESA Precision Measurement Instruments Sarl. All rights reserved. 4812.005.2610 - IP4812005