PMA-UNIFLEX-SG45
1 /8Pages

PMA-UNIFLEX-SG45

PMA-UNIFLEX-SG45
1 /8Pages

Catalog excerpts

PMA-UNIFLEX-SG45-1

UNIFLEX SG 45 Transmitter for load cells, strain gauges, and melt pressure sensors Energization: 10 VDC up to 125 mA sensor current Tare & zero adjustment Lead resistance compensation (4 or 6-wire connection) High resolution Fast cycle times Customer-specific linearization 80% switch for melt pressure calibration Communication port/field bus interface ^ Compact design, only 22.5 mm (0.87") wide ^ Clips onto top-hat DIN rail ^ Plug-in screw terminals or spring-clamp connectors - simple connection > Dual-l ine LC display with additional display elements ^ process values always in view ^ Convenient 3-key operation ^ Direct communication between mounted controllers, fieldbus connections via bus coupler ^ Measurement input with high signal resolution (23 bits) ^ Universal high-resolution output (14 Bit) as combined voltage/current output ^ Two relay outputs ^ Quick response; only 50 ms cycle time, i.e. also suitable for fast signals ^ Customer-specific linearization ^ Dead load compensation and tare adjustment ^ Min/max indicator ('slave pointer') ^ Preset for output value ^ Zero setting with adjustable limit value The Uniflex SG 45 is a transmitter for processing and monitoring input signals form strain gauges, load cells, melt pressure sensors, and resistance bridges. It can be used in practically all industrial applications involving the precise measurement, indication, and processing of force, weight, or melt pressure. Moreover, it permits operation and parameter adjustment via keys in the front panel. Alternatively, the Uniflex SG 45 can be operated, parametrized, and calibrated by means of a PC and a connection adapter. This also permits the adjusted parameters and configuration to be documented during operation. The simple zero setting function ensures high operating convenience.

 Open the catalog to page 1
PMA-UNIFLEX-SG45-2

MEASUREMENT SPAN: * All logic signals can be "OR-linked". Output values can also be forced via interface. Contact type: Max. contact rating: Min. contact rating: Switching cycles (electrical): The compact KS 45 is clipped onto a top-hat DIN rail, and can also be unmounted very simply. All connections are of the plug-in type, so that a controller can be replaced very quickly without disturbing the wiring. Display and operation The dual-line LC display permits simultaneous indication of the measured value and all of the unit's operating functions. Moreover, a LED and 4 other display elements give...

 Open the catalog to page 2
PMA-UNIFLEX-SG45-3

Parallel current/voltage output with common 'minus' terminal (combined use only in galvanically isolated circuits). Freely scalable Resolution: 14 bits Tracking error I/U: < 2 % Current output 0/4...20 mA, configurable, short-circuit proof. Control range: Load: Load effect: Resolution: Error: Voltage output 0/2...10V, configurable, not permanently short-circuit proof Control range: 0 11,5V Load effect: < 0,06% Additional error when using < 0,09% simultaneously the current output Isolation: between in-/output against < 33 V AC earth: Customer specific linearisation Up to 31 segments...

 Open the catalog to page 3
PMA-UNIFLEX-SG45-4

Sensor break, short circuit, incorrect polarity Stored limit values E.g. Re-calibration warning (message is generated when a predefined operating time is reached) E.g. Maintenance interval for a switching device (message is generated when a predefined number of switching cycles is reached) Internal fault (RAM, EEPROM,...) • Linearization with 31 segments Behaviour on sensor break/short circuit • Response of the analog output is selectable (upscale / downscale) • Preset substitute input value, can be disabled Tare function Setting the tare signal the actual process value is reset to zero. Further measurements...

 Open the catalog to page 4
PMA-UNIFLEX-SG45-5

Green, no data exchange with bus blinking: coupler (only for devices with system option) Red: limit value Lim1 exceeded Red, blinking: internal fault, configuration mismatch Operating functions Only three keys at the front of the KS 45 are used to operate process values, parameters, and configuration data. Different Operating Levels and selected parameters can be disabled by means of BlueControl®. POWER SUPPLY Depending on ordered version: AC supply Voltage: 90...260VAC Consumption: approx. 4 VA / 3W max. Supply only with protective low voltage (SELV) * Devices with system option: They...

 Open the catalog to page 5
PMA-UNIFLEX-SG45-6

GENERAL Housing front Material: Polyamide PA 6.6 Flammability class: VO (UL 94) Connecting terminals Material: Polyamide PA Flammability class:V2 (UL 94) for screw terminals V0 (UL 94) for spring-clamp terminals and bus connector Electrical safety Complies with EN 61 010-1 Over-voltage category II Contamination degree 2 Protection class II Electrical connections Plug-in connector strips with choice of terminal type: • Screw terminals or spring-clamp terminals, both for lead cross-sections from 0.2 to 2.5 mm2. (AWG24-12) Mounting method Clip-on rail mounting (35 mm top-hat rail to EN...

 Open the catalog to page 6
PMA-UNIFLEX-SG45-7

O Connector set with screw terminals 4 pcs. © Connector set with spring-clamp terminals 4 pcs. O Plug for bus connection, inverted, connections 1 piece at left, horizontal cable entry © Plug for bus connection, connections at right, 1 piece vertical cable entry Description PC adapter for the BluePorf front interface USB serial adaptor (USB to RS 232) Converter RS 232 to RS 422/485 ® BlueControl Mini BlueControf with Basic license rail line BlueControf with Expert license rail line galv. isolated German/English German/English German/English Standard accessories: • Operating notes • Devices...

 Open the catalog to page 7
PMA-UNIFLEX-SG45-8

ORDERING DATA SYSTEM COMPONENTS 1 measuring input, 1 digital input with display and BluePort®-interface Fieldbuscoupler PROFIBUS DP, UL/cUL RL40-112-00000-U00 Fieldbuscoupler Modbus TCP RL40-114-00000-000 Fieldbuscoupler Modbus TCP, UL/cUL RL40-114-00000-U00 Power supply module RL40-119-00000-000 Power supply module, UL / cUL RL40-119-00000-U00 UL/cUL - certification * U ^ Please order the associated documentation Operating instructions SG 45 (D) Operating instructions SG 45 (E) Interface description for MODBUS rail line (D) Interface description for MODBUS rail line (E) Interface...